Chapter 2: Precautions for Use

Pay attention to the points below when handling the IV-C35M.
(1) Installation
-
Each device in the IV-C35M system must be installed in an environment as specified in this manual.
(Operating ambient temperature: 0 to 45˚C, operating ambient humidity: 35 to 85%RH (non-
condensing.))
-
Do not install the devices in the following locations. Installation in any of these locations may
cause electrical shock, fire, or malfunction of the devices.
1. Places exposed to direct sunlight
2. Places with exposed to corrosive gases
3. Places with excessive amounts of dust, salt, or metal powder in the air.
4. Places exposed to water
(2) Mounting
Make sure to tighten the mounting and terminal screws securely and check everything before
supplying power. A loose screw may cause faulty operation.
(3) Power source
-
Do not use the IV-C35M (power supply for the controller) power supply with any other
equipment.
-
Do not turn OFF the power while the menu is displayed or while communicating with external
equipment. Turning OFF the power may erase the data settings.
(4) Connection of cameras
Note that the IV-C35M cannot be connected with EIA cameras that are available on the market.
(5) Measurement settings
Make sure to specify 4000 ms (4 seconds) or less for the measurement processing time on each
measurement item (MEASUREMENT 0 CAMERA 1, MEASUREMENT 0 CAMERA 2, and
MEASUREMENT 1 to 4). For example, if the various tasks require 7000 ms of measurement
processing time, assign 3500 ms to MEASUREMENT 1 and 3500 ms to MEASUREMENT 2 so that
each of the assigned processing times is less than 4000 ms.
If the measurement processing time exceeds 4000 ms, the IV-C35M assumes that an abnormal
operation has occurred and may try to reset the system.
(6) Data saving
-
The data set by using the remote keypad is temporarily stored in the memory (RAM) of the IV-
C35M. However, it is not stored in the flash memory yet. Therefore, make sure to save the data
settings before returning to the operation screen from any condition settings menu by pressing
the SET key. If you do not save the data, the data will disappear when you turn OFF the power
to the IV-C35M controller.
-
We recommend that you save the data settings and reference images on a floppy diskette using
the IV-S30SP parameter setting support software for the IV-C35M.
(7) Storing the devices
Do not put any object on top of any of the devices, or the device may malfunction.
(8) Maintenance
Be careful not to get any dirt or stains on the CCD surface or camera lens. This may cause mis
measurement.