® MULTI XS 4003 Battery charger For lead-acid batteries 1.2–140Ah Model 1035 User’s Manual and a guide to professional battery charging for starter/deep cycle batteries.
QUICK GUIDE MULTI XS 4003 For details – see manual Connect the red lead to the positive pole of the battery and the black lead to the negative pole. – When you are sure the battery leads are correctly placed, connect the charger to the wall socket.
Page 4
Congratulations on purchasing your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging. Please read this user´s manual and follow the instructions carefully.
BATTERY TYPES AND SETTINGS The MULTI XS 4003 model offer several alternative settings to suit specific charging needs and required functionality. The following recommendations should only be regarded as guidelines. Please observe the battery manufacturer recommendations in the event of uncertainty. Settings are made by pressing the “MODE-button” and stepping forward one press at a time until the required mode is reached, the button is then released.
The table explains the various lamps: Mains voltage connected. If the mode is incorrect, the charger cuts the charging/voltage supply. The charger switches to error mode before starting in the following circumstances: If the battery has been connected with reverse polarity to the charger terminals.
If the battery leads are incorrectly connected, the reverse polarity protection will ensure that the battery and charger are not damaged. Start charging 1. When you are sure the battery leads are correctly placed, connect the charger to the wall socket. The charger will indicate that the mains voltage is connected. If the battery leads are incorrectly connected, the reverse polarity protection will ensure that the battery and charger are not damaged.
Analysis Tests the self-discharge. If the self discharge is too high, the charging is interrupted and error mode indicated. Recond Reconditioning of deeply discharged batteries. This step is used to restore deeply discharged open vented batteries. With increased charging voltage over a limited time, the voltage is allowed to rise so that the battery starts to emit gas.
A defective mains cable has to be replaced by CTEK or by a representative authorised by CTEK. Keep your charger clean. Wipe it with a soft tissue and mild cleaning liquid. The charger must be disconnected for cleaning.
PROGRAM DESCRIPTION Desulphation Soft start Bulk Absorption Revives a Tests the state Top charge and Main charge sulphated battery of the battery minimal fluid loss 4A for max 8h until the 4A for max 20h. A combination of voltage reaches 12.6V. current limits and timers, max 10h.
Page 11
Analysis Recond Float Pulse Tests whether the Reconditioning Maintenance for Maintenance for battery can retain of deep discharged maximum performance maximum service life energy batteries Alerts the user if the Max 15.8V and 1.5A for 13.6V with max 4A for Pulse starts at 12.9V, voltage drops to 12V in 4h for deep discharged...
LIMITED wARRANTY CTEK SWEDEN AB, Rostugnsv. 3, SE-776 70 VIKMANSHYTTAN, SWEDEN issues this limited warranty to the original purchaser of this product. This limited warranty is not transferable. The warranty applies to manufacturing faults and material defects for 5 years from the date of purchase. The customer must return the product together with the receipt of purchase to the point of purchase.