GE 489 Instruction Manual page 194

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6.3 MODBUS MEMORY MAP
Table 6–1: 489 MEMORY MAP (SHEET 23 OF 24)
ADDR NAME
2D83
FAULT Iphase NEUTRAL
2D84
FAULT CURRENT GROUND
2D85
FAULT VOLTAGE NEUTRAL
2D86
FAULT STATOR RTD TEMP
2D87
FAULT BEARING RTD TEMP
2D88
FAULT OTHER RTD TEMP
2D89
FAULT AMBIENT RTD TEMP
2D8A
FAULT SYSTEM FREQUENCY
2D8B
FAULT ANALOG INPUT 1
2D8C
FAULT ANALOG INPUT 2
2D8D
FAULT ANALOG INPUT 3
2D8E
FAULT ANALOG INPUT 4
2DBC
FAULT STATOR RTD TEMP
2DBD
FAULT BEARING RTD TEMP
2DBE
FAULT OTHER RTD TEMP
2DBF
FAULT AMBIENT RTD TEMP
489 TESTING / TEST OUTPUT RELAYS
2DE0
FORCE OPERATION OF RELAYS
489 TESTING / TEST ANALOG OUTPUT
2DF0
FORCE ANALOG OUTPUTS FUNCTION
2DF1
ANALOG OUTPUT 1 FORCED VALUE
2DF2
ANALOG OUTPUT 2 FORCED VALUE
2DF3
ANALOG OUTPUT 3 FORCED VALUE
2DF4
ANALOG OUTPUT 4 FORCED VALUE
EVENT RECORDER / GENERAL
3000
EVENT RECORDER LAST RESET DATE (2 WORDS)
3002
TOTAL NUMBER OF EVENTS SINCE LAST CLEAR
3003
EVENT RECORD SELECTOR
EVENT RECORDER / SELECTED EVENT
3004
CAUSE OF EVENT
3005
TIME OF EVENT (2 WORDS)
3007
DATE OF EVENT (2 WORDS)
3009
TACHOMETER
300A
PHASE A CURRENT
300C
PHASE B CURRENT
6
300E
PHASE C CURRENT
3010
PHASE A DIFFERENTIAL CURRENT
3012
PHASE B DIFFERENTIAL CURRENT
3014
PHASE C DIFFERENTIAL CURRENT
3016
NEG. SEQ. CURRENT
3017
GROUND CURRENT
3019
A-B VOLTAGE
301A
B-C VOLTAGE
301B
C-A VOLTAGE
301C
FREQUENCY
301D
ACTIVE GROUP
301F
REAL POWER (MW)
3021
REACTIVE POWER Mar
3023
APPARENT POWER MVA
3025
HOTTEST STATOR RTD #
3026
HOTTEST STATOR RTD TEMPERATURE
3027
HOTTEST BEARING RTD #
3028
HOTTEST BEARING RTD TEMPERATURE
3029
HOTTEST OTHER RTD #
302A
HOTTEST OTHER RTD TEMPERATURE
302B
HOTTEST AMBIENT RTD #
302C
HOTTEST AMBIENT RTD TEMPERATURE
302D
ANALOG IN 1
302F
ANALOG IN 2
3031
ANALOG IN 3
3033
ANALOG IN 4
3035
PHASE A NEUTRAL CURRENT
3037
PHASE B NEUTRAL CURRENT
3039
PHASE C NEUTRAL CURRENT
30E0
HOTTEST STATOR RTD TEMPERATURE
30E1
HOTTEST BEARING RTD TEMPERATURE
1, 2, 3
See Table footnotes on page 6–33
6-32
RANGE
0 to 2000
0 to 2000
0 to 1000
–50 to 250
–50 to 250
–50 to 250
–50 to 250
50 to 900
0 to 100
0 to 100
0 to 100
0 to 100
–50 to 250
–50 to 250
–50 to 250
–50 to 250
0 to 8
0 to 1
0 to 100
0 to 100
0 to 100
0 to 100
N/A
0 to 65535
0 to 65535
0 to 139
N/A
N/A
0 to 7200
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 2000
0 to 20000000
0 to 50000
0 to 50000
0 to 50000
0 to 12000
0 to 1
–2000000 to 2000000
–2000000 to 2000000
0 to 2000000
1 to 12
–50 to 250
1 to 12
–50 to 250
1 to 12
–50 to 250
1 to 12
–50 to 250
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
0 to 999999
0 to 999999
0 to 999999
–50 to 250
–50 to 250
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
× CT
F3
× CT
1
F3
1
Volts
F2
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
Hz
F2
1
%
F1
1
%
F1
1
%
F1
1
%
F1
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
F139
1
F126
1
%
F1
1
%
F1
1
%
F1
1
%
F1
N/A
N/A
F18
1
N/A
F1
1
F1
1
F134
N/A
N/A
F19
N/A
N/A
F18
1
RPM
F1
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
%FLA
F1
1
A
F14
1
Volts
F1
1
Volts
F1
1
Volts
F1
1
Hz
F3
1
F1
1
MW
F13
1
Mar
F13
1
MVA
F13
1
F1
1
°C
F4
1
F1
1
°C
F4
1
F1
1
°C
F4
1
F1
1
°C
F4
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
°F
F4
1
°F
F4
DEFAULT
0
0
0
40
40
40
40
600
0
0
0
0
40
40
40
40
0
0
0
0
0
0
N/A
N/A
0
0
N/A
N/A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0