NEC Express5800 320Fd-MR User Manual page 149

Hide thumbs Also See for Express5800 320Fd-MR:
Table of Contents

Advertisement

Hang of snmpd Service
Snmpd Service has a module called "SNMP Extended Agent." This module may be registered when
you install some software that uses snmpd Service.
If you start snmpd Service, SNMP Extended Agent is also loaded at the initialization. However, if
the initialization is not completed within a specified period, snmpd Service will hang.
It may take time to complete the initialization due to temporary high load on the system. In this case,
wait for the system load become low enough before restarting snmpd Service.
Operation when Temperature/Voltage Error Occurs on the CPU/PCI Modules
At the time when a temperature or voltage error occurs on CPU/PCI module, necessary actions will
differ depending on their status as shown below. You can check the status of each module from the
data viewer of NEC ESMPRO Manager or ftServer Utility.
Status
Duplex
Other than Duplex and Empty
TIPS:
If the status is "Empty", the module is not mounted. Sensor monitoring is not conducted.
If disks are mounted on PCI modules, the status of both modules is "Simplex" while the disks
are mirrored. Temperature or voltage error occurring during disk mirroring will result in the
system to shut down.
Shutdown Monitoring
When performing shutdown monitoring, all shutdown processes are to be monitored. If there is an
application that performs shutdown without rebooting OS or turning off the power, set the timeout
value longer or disable the monitoring function.
CPU Information
In [CPU Information] of DataViewer's system tree, the external clock is listed as "Unknown."
When [ft] Tree Appears on Date Viewer in an Incorrect Manner
If you open a DataViewer or reconfiguration of the tree immediately after starting the system or
starting/stopping CPU/PCI module, the [ft] tree side of the DataViewer may not be displayed
correctly. Wait about five minutes and then start the Data Viewer again.
Operation
Stop the failed CPU/PCI module
Shut down the system.
Installing and Using Utilities 5-19