Installing and Using Utilities 5-29
Change Settings of File System Monitoring Function
New settings in thresholds of monitoring interval and free space monitoring are not reflected
immediately after they are changed. They are reflected at the next monitoring interval of monitoring
service.
CPU Load Ratio of SNMP Service (snmp.exe)
While monitoring the server from NEC ESMPRO Manager, the CPU load ratio of SNMP Service
on the NEC ESMPRO Agent side may increase at every monitoring interval (default: 1 minute).
NEC ESMPRO Manager and NEC ESMPRO Agent exchange information through SNMP Service.
If the server status monitoring by NEC ESMPRO Manager is on (default: ON), NEC ESMPRO
Manager regularly issues a request to NEC ESMPRO Agent to get the current status of the server. In
response, NEC ESMPRO Agent checks the status of the server. As a result, the CPU load ratio of
SNMP Service increases temporarily.
If you have trouble of terminating a movie player application, turn off the server status monitoring
by NEC ESMPRO Manager or extend the monitoring interval.
Hang of SNMP Service
SNMP Service has a module called "SNMP Extended Agent." This module may be registered when
you install some software that uses SNMP Service.
If you start SNMP Service, SNMP Extended Agent is also loaded at the initialization. However, if
the initialization is not completed within a specified period, SNMP Service will hang.
It may take time to complete the initialization due to temporary high load on the system. In this case,
wait for the system load become low enough before restarting SNMP Service.
Pop-up message of esmcmn.exe is displayed when starting the system:
The following pop-up message may be displayed when you restart the system which NEC
ESMPRO Agent is installed to and removal drives such as MO and DVD-RAM are mounted on,
without closing Windows Explorer, after displaying the contents of media and removing the media
by the software eject (by right-clicking the DVD drive on Windows Explorer and selecting [Eject])
The message (the drive name) displayed varies depending on the systems.
If the pop-up message "There is no disk in the drive. Please insert a disk into drive A:." is displayed,
click [Cancel] or [Continue] to close the dialog box. If you do not close the dialog box, you cannot
start the Workstation service and related services, causing unstable operation of the system. Also, if
you restart the system, execute it after terminating the program such as Windows Explorer which
displays a media.