Option List; Stand-Alone Options - Mitsubishi Electric FR-A500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR-A500:
Table of Contents

Advertisement

8.1 Option List

8.1.1

Stand-alone options

Name
Parameter unit
FR-PU04
(8 languages)
Parameter unit
FR-CB2
connection cable
Heatsink outside
FR-A5CN
attachment
Totally enclosed
FR-A5CV
structure attachment
Attachment for conduit
FR-A5FN
connection
FR-A200E series
installation interchange
FR-A5AT
attachment
EMC Directive
compatible noise filer
SF
(Note 3)
FR-ABR-(H)
High-duty brake resistor
(Note 1)
Surge voltage
FR-ASF-H
suppressing filter
Power factor improving
FR-BEL-(H)
DC reactor
(Note 1)
Power factor improving
FR-BAL-(H)
AC reactor
(Note 1)
FR-BIF-(H)
Radio noise filter
(Note 1)
FR-BSF01
Line noise filter
FR-BLF
BU-1500 to 15K,
BU brake unit
H7.5K to H30K
FR-BU-15K to 55K,
Brake unit
H15K to H55K
FR-BR-15K to 55K,
Resistor unit
H15K to H55K
Power regeneration
FR-RC-15K to 55K,
converter
H15K to H55K
FR-CV 7.5K to 30K(-
Power regeneration
AT), 37K, 55K, H7.5K
common converter
to H30K(-AT), H37K,
H55K (Note 5)
FR-CV dedicated
FR-CVL-7.5K to 55K,
stand-alone reactor
H7.5K to H55K
FR-CV dedicated
FR-CVL-7.5K to 55K,
stand-alone reactor
H7.5K to H55K
High power factor
FR-HC7.5K to 55K,
converter
H7.5K to H55K
Type
Interactive parameter unit using LCD display (For use in
Japanese, English, German, French, Spanish, Italian, Swedish
and Finnish)
Cable for connection of the operation panel or parameter unit.
Used to place only the heat generating section of the inverter in
the back of the control box.
By installing this option, the inverter meets the totally enclosed
structure specifications (IP40).
Used to connect a conduit directly.
Mounting plate used to make the mounting dimensions identical to
those of the FR-A200<EXCELLENT> series.
Noise filer conforming to the EMC Directive (EN50081-2)
Used to improve the braking capability of the brake built in the
inverter.
Suppresses surge voltages on the inverter output side.
Used to improve the inverter input power factor (overall power
factor about 95%) and cooperate with the power supply.
Used to improve the inverter input power factor (overall power
factor about 90%) and cooperate with the power supply.
For radio noise reduction. Leakage current 4mA.
For line noise reduction (applies to small capacities of 3.7kW or
less)
For line noise reduction
Used to improve the braking capability of the inverter (for high-
inertia load or negative load).
Used to improve the braking capability of the inverter (for high-
inertia load or negative load). Use the brake unit and resistor unit
together.
High-function brake unit which can return motor-generated
braking energy to the power supply.
High function unit which can return motor-generated braking
energy back to the power supply in common converter system.
FR-CV dedicated power cooperative reactor.
FR-CV dedicated power cooperative reactor.
The high power factor converter switches the converter circuit on-
off to convert the input current waveform into a sine wave to
suppress harmonics considerably. (Used with the standard
accessories.)
Application, Specifications, etc.
226
OPTIONS
Applicable
Inverter
Common to
all models
1.5K to 55K,
according to
capacity
0.4K to 22K,
according to
capacity
30K to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
0.4 to 55K,
according to
capacity
0.4K to 7.5K,
according to
capacity
0.4 to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
Common to
all models
According to
capacity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents