Troubleshooting - Husqvarna 1365GN Operator's Manual

Hide thumbs Also See for 1365GN:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting
TROUBLESHOOTING
Problem
No AC output is available,
but
generator
is running.
Generator runs good at no-load
but "bogs"
down" when loads are
connected.
Cause
1.
One of the circuit breakers is
open.
2.
Fault in generator.
3.
Poor connection or defective
cord set.
4.
Connected device is bad.
1.
Short circuit in a connected
load.
2.
Generator is overloaded.
3.
Shorted generator circuit.
Generator will not start; or starts
Low oil level.
and runs rough.
1.
Out of fuel.
Generator
shuts down during
operation.
2.
Low oil level.
Generator
lacks power.
Load is too high.
Correction
1.
Reset circuit breaker.
2.
Contact Authorized service
facility.
3.
Check and repair.
4.
Connect another device that is
in good condition.
1.
Disconnect shorted electrical
load.
2.
See "Don't Overload Generator".
3.
Contact Authorized service
facility.
Fill crankcase to proper level or
place generator on level surface.
1.
Fill fuel tank.
2.
Fill crankcase to proper level or
place generator on level surface.
See "Don't Overload Generator".
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents