Troubleshooting Tips.
Possible Causes
What To Do
Air conditioner
The air conditioner
• Make sure the air conditioner
plug is pushed
does not start
is unplugged,
completely
into the outlet.
The fuse is blown/circuit
• Check
the house fitse/circuit
breaker
box and replace
breaker
is tripped,
the fitse or reset the breakeL
Power
failure,
• The unit will automatically
re-start in file settings
last
used after file power is restored.
• There
is a protective
time
delay
(approximately
3 minutes)
to prevent
tripping
of the compressor
overload.
For this reason,
the unit may not start
normal
cooling
for 3 minutes
after it is turned
back on.
The
current
interrupter
device
is tripped.
• Press the RESETbuttonlocated on the power cord plug.
• If tim RESETbutton will not stay engaged,
discontinue
use of the air conditioner
and contact a qualified
service teclmician.
Air conditioner does
Airflow is restricted.
• Make sure there are no curtains,
blinds
or fiuniuue
not coolas itshould
blocking
the flont of the air condifioneL
The temp control may
• On models
with touch
pads: In the Cool mode, press the
not be set correctly.
Decrease • pad.
• On models
wifll control
knobs,
turn the temperature
knob to a higher
numbeL
The air filter is dirty.
• Clean the filter at least eve_ T 30 days.
See the Care and Cleaning section.
The room may have been hot.
• When
the air conditioner
is first turned
on, you need
m allow time for the room m cool down.
Cold air is escaping.
• Check for open
fiunace
registers
and cold air reuuns.
Cooling
coils have iced up.
• See "Air conditioner freezing up" below.
Air conditioner
freezingup
Ice blocks
the air flow
and stops the air conditioner
from cooling
the room.
• On models
Mill conUol
knobs, set file mode
conuol
at
High Fan or High Coolwith
the Tempat I or 2.
• On models
with touch
pads, set the controls
at High Fan
or High Cool and set the thermostat
m a higher
temperature.
The remote control
The batteries
are inserted
• Check
file position
of file batteries.
They should
be
is not working
incorrectly,
inserted
in the opposite
(+) and
(-) direction.
The batteries
may be dead.
• Replace
the batteries.
Water drips outside
Hot, humid
weather.
• Tiffs is nomml.
Water drips indoors
The
air conditioner
is not
• For proper
water disposal,
make sure file air conditioner
tilted to the outside,
slants slightly flom the case flont
to the real
Water collects in
Moisture
removed
from air
• Tiffs is nomml
for a short period
in areas with little
base pan
and drains into base pan.
humidity;
normal
for a longer
period
in re, y humid
are_ts.
Normal Operating Sounds
You may hear a pinging noise caused by wamr
being picked tap and tinown against the
condenser on rainy days or when the humidity
is high. This desigm feaune helps remove
moisune and improve efficiency.
}_You may hear the thermostat click when the
compressor cycles on and off:
Water will collect in file base pan during
high humidity or on rainy days. The wamr
m W overflow and drip flom the outdoor side
of the unit.
}i_ The fan may run even when the compressor
does not.
w
r_,_
r_
g
m
¢b
!
!