Installation instructions
Install
the
shutoff
valve
on the
nearest
frequently
used
drinking
water
line.
m SHUT OFF THE MAIN WATER
SUPPLY AND UNPLUG
REFRIGERATOR
Turn on tile nearest
faucet (counterclockwise)
long
enough
to clear the line of water.
[]
DRILL THE HOLE FOR THE VALVE
Choose
a location
for the valve
that
is easily
accessible.
It
is best
to com_ect
into the
side of a vertical
water
pipe.
When
it is necessary
to connect
into a horizontal
water
pipe,
make
the
com_ection
to
the
top
or
side,
rather
than
at the bottom,
to avoid
drawing
off any
sediment
from
the water
pipe.
Drill
a 1/4"
hole
in tile water
pipe
ieven
if using
a self-
piercing
wdve),
using
a sharp
bit. Remove
any burrs
resulting
from
drilling
the hole in the pipe.
Take
care
not to allow
water
to drain
into
the drill.
Failure
to drill
a 1/4"
hole
may
result
in reduced
ice production
or
smaller
cubes.
m
FASTEN THE SHUTOFF VALVE
Fastenthe shutoff valve to the cold water pipe with the
pipe clamp.
Tighten
the
clamp
screws
until
the sealing
washer
begins
to swell.
NOTE: Do
not overtighten
or you may
crush
the
mbing.
Washer
PipeClaml--
End
Claml
Saddle-Type
ShutoffValve
-Vertical C old
Water Pipe
NOTE: Commomsealth
of Massachusetts Plumbing
9
Codes _48CMR shall be adhered to. Saddle valves are
illegal and use is not permitted in Massachusetts. Consult
with your licensed plumber.
9
N] ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator or adjacent base cabinet) as
close to the wall as possible.
NOTE: Be sure there is sufficient extra tubing (about 8
feet [244 cm] coiled into 3 turns of about 10" [25 cm]
diameter) to allow the refrigerator to move out from the
wall after installation.
CONNECT
THE TUBING
TO THE VALVE
Place the compression
nut and ferrule (sleeve)
fi_r copper
tubing onto the end of the tubing
and
com_ect it to the shutoff valve.
Make sure the tubing
is fully inserted
into the
valve. Tighten
the COlnpression
nut securel>
For plastic tubing from a GE SmartConnect
,M
Refrigerator
Tubing
kit, insert the molded
end
of the tubing
into the shutoff valve and tighten
compression
mlt until it is hand
tight, then tighten
one
additional
turn with a wrench.
Overtightening
may
cause leaks.
?ression
Nut
Saddle-Type
ShutoffValve
:_
SmartConnect _
Tubing
PackingNut
Outlet V alve
Ferrule ( sleeve)
NOTE: Commonwealth
of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and use is not permitted in Massachusetts. Consult
with your licensed plumber.
FLUSH OUT THE TUBING
Turn the main water supply on (counterclockwise) and
flush out the tubing until the water is clear.
Shut the water off at the water valve after about
one quart (1 liter) of water has been flushed through the
@

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents