Figure 14-5. LLDP-MED Policies TLV
TLV Type
TLV Length
(127)
(8)
7 bits
9 bits
Extended Power via MDI TLV
The Extended Power via MDI TLV enables advanced power over ethernet (PoE) management between
LLDP-MED endpoints and network connectivity devices
MDI on all ports that are connected to an 802.3af powered, LLDP-MED endpoint device.
•
Power Type—there are two possible power types: power sourcing entity (PSE) or power device (PD).
The Dell Force10 system is a PSE, which corresponds to a value of 0, based on the TIA-1057
specification.
•
Power Source—there are two possible power sources: Primary and Backup. The Dell Force10 system
is a Primary Power Source, which corresponds to a value of 1, based on the TIA-1057 specification.
•
Power Priority—there are three possible priorities: Low, High, and Critical. On Dell Force10
systems, the default power priority is High, which corresponds to a value of 2 based on the TIA-1057
specification. You can configure a different power priority through the CLI. Dell Force10 also honors
the power priority value sent by the powered device. However, the CLI configuration takes
precedence.
•
Power Value—Dell Force10 advertises the maximum amount of power that can be supplied on the
port. By default it is 15.4W, which corresponds to a Power Value of 130, based on the TIA-1057
specification. You can advertise a different Power Value using the
inline auto
powered device when the port is configured for
Figure 14-6. Extended Power via MDI TLV
TLV Type
TLV Length
(127)
7 bits
9 bits
174
|
Link Layer Discovery Protocol (LLDP)
Organizationally
Organizationally
Unique ID
Defined Sub-type
(00-12-BB)
3 octets
1 octet
|
command. Dell Force10 also honors the power value (power requirement) sent by the
static
Organizationally
Organizationally
Unique ID
Defined Sub-type
(7)
(00-12-BB)
3 octets
Application Type
U
(0-255)
(2)
1 octet
3 bits
(Figure
power inline auto
Power Type
Power Source
(0)
(4)
2 bits
1 octet
2 bits
X
T
L2 Priority
VLAN ID
(0)
(0-7)
(0-4095)
12 bits
3 bits
14-6). Advertise the Extended Power via
option with the
max-milliwatts
.
Power Priority
Power Value
(1)
(2)
(130)
4 bits
2 octets
DSCP Value
(0-63)
6 bits
power