4.3.2 Problems and Countermeasures

Master Unit LED
MS
NS
Green
Green
Light ON
Light ON
Green
Green
Light ON
Light
Blinking
Green
Red Light
Light ON
Blinking
Green
Light OFF
Light ON
Red Light
No Matter
Blinking
Red Light
No Matter
ON
Light OFF
No Matter
Light OFF
Light OFF
Fieldbus I/O Rev.6
Error
Normal
- Normal condition
communication
During connection
- Processing connection establishment
establishment
- Master function in stop state
Communication
- Network channel error
timeout
IP address not
- The IP address is not defined
defined
Critical error
- Unrecoverable critical error
Module error
- Recoverable error occurred
error
- No slave (Error detection before communication
- Communications power supply OFF
Not initialized status
Slave Mode.]
- The communication board is not initialized
Check the configuration
4. Troubleshooting (EtherNet/IP)
Description [Reference]
(The NS LED will be ON in green in a few seconds.)
(Communication does not start.)
[Refer to the section 4.3.3 Tests and diagnostics.]
[Refer to the section 4.3.3 Tests and diagnostics.]
[Refer to the section 4.1.2.5 Absent Slave.]
establishment)
[Refer to the section 2.9.5 Master Mode and 2.9.6
143