Alarm Text Files - Fujitsu ETERNUS User Manual

Hide thumbs Also See for ETERNUS:
Table of Contents

Advertisement

Chapter 6 Messages
>

6.2 Alarm Text Files

Example Alarm History File
The following alarm history file was created on December 1st 2008 for an ETERNUS4000
with the target address 10.20.30.40.
ETERNUS4000 Hardware Status List
Date:1/12/2008
ETERNUS4000 Address:10.20.30.40
ControllerEnclosure#0001:ALARM
ControllerEnclosure#0002:BTU-CAUTION
ControllerEnclosure#0003:ALARM&BTU-CAUTION
DriveEnclosure#0003:ALARM
ETERNUSmgr(stxpoll) V20L30
The "alarm history messages" shown above indicate the status results obtained from the target
device.
The following message is output when all components of the target device are normal.
"No hardware error detected."
If target device monitoring does not work properly (due to LAN drop-out, failure on the network
path, or incorrect target address setting, etc.), and the Detect Offline Targets parameter has
been set, the following message will be output.
"No hardware report detected. (Offline)"
See
"6.3 E-mail Messages" (page
of the messages displayed in the alarm history file.
Note that "Hardware Status was changed. See below ..." is not an actual alarm history message.
6.2
Alarm Text Files
This section explains the alarm text files that are generated by ETERNUSmgr.
Alarm text files are a compilation of the alarm history messages for a single day in a text format.
See
"6.1 Alarm History Messages" (page 52)
sages.
Alarm text files are categorized into the following types:
Alarm Text Date Files
Contains the individual alarm history messages that record the ongoing status of the target
device, collected on a day-by-day basis.
Alarm Text Fixed File
Contains the same alarm history messages as the latest alarm text date file, saved under a
settable name.
P2X0-0202-04ENZ0
ETERNUS Disk storage systems ETERNUSmgr User Guide -Introduction-
Header
(title, date, address of the target device)
Alarm List
Footer
(ETERNUSmgr Version)
54), "Hardware Status was changed. See below ..." for details
for more information on the alarm history mes-
53
Copyright 2009 FUJITSU LIMITED