Chapter 2 Setup
>
2.3 Setting Items
[Default value]
TARGET_PORT = 80
(TARGET_ADDR must be set. There is no default.)
[Parameter]
TARGET_ADDR (up to 64 characters)
TARGET_PORT (0-65535)
[Example]
TARGET_ADDR=127.0.0.1 or TARGET_ADDR=host-name.domain-name.com
TARGET_PORT=80
Polling Interval
This parameter is used to control polling (periodically checking the status) of a target device.
Set the polling interval in units of seconds within the range of 1 ~ 65535.
[Default value]
300
[Parameter]
POLLING_TIME (1-65535)
[Example]
POLLING_TIME=300
This specifies the Polling Interval (time between the start of one poll to the next).
Due to network or device load the actual polling time may exceed the set time. In such cases, the
start of the next polling time is delayed until the previous polling finishes:
When the actual polling finishes within the scheduled polling time:
Scheduled polling
interval
Actual polling
interval
P2X0-0202-04ENZ0
ETERNUS Disk storage systems ETERNUSmgr User Guide -Introduction-
As the default port number is normally used, the target port parameter is
initially commented out.
If the target address is changed, the target address must also be
changed in the top menu ("menu.htm").
Per schedule
300 sec
300 sec
200 sec
150 sec
Scheduled start OK