Motor Requirements; Dual Control - DeWalt D55170 Instruction Manual

Contractor’s electric wheeled portable air compressor
Hide thumbs Also See for D55170:
Table of Contents

Advertisement

Available languages

Available languages

purchased at your local hardware or electrical
supply store. Follow the cord plug manufacturer
installation procedures, contact your local D
Service Center, qualified electrician or call 1-800-
4-D
WALT for proper procedures to install the plug.
E
The compressor must comply with all local and
national electrical codes after the 230 volt plug is
installed.
The compressor with the 230 volt plug should only be connected to
an outlet having the same configuration as the plug illustrated.

MOTOR REQUIREMENTS

UNITS WITHOUT A DUAL VOLTAGE SWITCH
WARNING: Make sure motor is disconnected from the power
source before rewiring motor leads.
The motor supplied with your compressor is a dual voltage, 115 / 230
volt motor. If it is desired to operate your compressor at 230 volts,
single phase, it is necessary to reconnect the motor leads in the motor
junction box by following the instructions given on the motor
nameplate. If unsure on how to reconnect the motor leads contact
your local D
WALT Service Center or qualified electrician for proper
E
procedures to install the plug.
WARNING: Make sure that the 230 volt cord plug end is properly
connected before operating in 230 volt mode.
UNITS WITH A DUAL VOLTAGE SWITCH
WARNING: Make sure that the 230 volt cord plug end is properly
connected before operating in 230 volt mode.
The motor supplied with your compressor is a dual voltage, 115/230
volt motor. If it is desired to operate your compressor at 230 volts,
single phase, simply move the 115/230 volt switch to the 230 volt
position.

DUAL CONTROL

(D55390, D55395, D55570, D55575, D55580, D55585)
WALT
E
NOTE: Unit must remain running while performing the following
adjustments
very hot; do not touch. (see the Hot Surfaces identified on page 2)
away from moving parts. Loose clothing, jewelry, or long hair can be
caught in moving parts. Air vents may cover moving parts and should
be avoided as well.
Stop Start Mode
1. Turn compressor on. If the tank has been fully charged,
2. Turn knob on top of pilot valve (H) clockwise until fully
damage to the pilot valve.
3. Allow compressor to reach cut out pressure. If
Constant Run Mode
1. Turn compressor on. If the tank has been fully charged, bleed air
2. Turn knob on top of pilot valve (H) fully counter-clockwise until fully
pilot valve.
3. Verify that the unit is in a constant run mode. If compressor shuts
6
WARNING : Aftercooler, pump head, and surrounding parts are
WARNING - Moving Parts: Keep your hair, clothing and gloves
bleed air from the drain valves until pump starts.
closed.
WARNING : Over tightening of this knob can cause
compressor does not stop, drain the tank(s) until
compressor begins to charge the tank(s) and readjust
pilot valve knob.
from the drain valves until pump starts.
open.
WARNING : Over loosening of this knob can cause damage to the
off, adjust pilot valve to a lower cut out pressure until unit continues
to run.
H

Advertisement

Table of Contents
loading

Table of Contents