Dell PowerEdge 180AS User Manual page 254

Remote console switch system
Hide thumbs Also See for PowerEdge 180AS:
Table of Contents

Advertisement

Trap
Trap Message
ID
24
Subsystem
Upgrade started.
Device ID: %s.
25
Subsystem
restarting.
Device ID: %s.
26
Communication
problems in the
system
configuration.
Device ID: %s.
27
Memory
problem.
Device ID: %s
28
Watchdog reset.
Device ID: %s.
29
Special
condition was
trapped. Device
ID: %s.
237
Appendix D: MIBs and SNMP Traps
Severity
Description
Informational The Remote Console Switch has started a
Subsystem Upgrade.
This can be a download from the DModule to
the main board, or an SIP or other subsystem
download from the main board.
Information about the subsystem being
updated is stored in the
dsTrapObjectFirmwareCondition object.
NOTE:
sent.
Informational The Remote Console Switch has completed a
download and is restarting the subsystem
specified in the
dsTrapObjectFirmwareCondition object.
NOTE:
sent.
Major
The Remote Console Switch has detected
communication problems in the system
configuration. This can be used to indicate
install problems that might result in
perceived problems with the switch.
Critical
The Remote Console Switch has detected a
memory problem, the nature of which has
been described in the
dsTrapObjectFirmwareCondition object.
Critical
The Remote Console Switch has detected a
watchdog reset condition. This indicates a
catastrophic failure in the firmware/hardware
preventing normal operation of the Remote
Console Switch.
Informational The Remote Console Switch has detected a
special condition to be trapped for
diagnostics. The condition has been recorded
is stored in the
dsTrapObjectFirmwareCondition object.
This trap is deprecated and is no longer
This trap is deprecated and is no longer

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents