Configure the Thermostat
On initial setup, the thermostat will go to the ISU menu. S200 models will
ask if you wish to perform setup on the device or by using the app. If
entering the ISU menu on the device after initial setup, follow the steps
below:
1. Press and hold the bottom left button and Up arrow
seconds to access the
INSTALLER MENU
2. Press
or
to cycle through
is displayed, press
SELECT.
3. The display shows the
ISU number
the right.
When an
ISU number
is displayed, press
for that ISU.
4. After choosing the correct setting for an ISU, press
to the next ISU setting.
5. To finish setup, press the
settings and return to the Home screen.
Installer Setup Options (ISU)
Depending on system settings, not all options may be available
#ISU
ISU Name
1040
Scheduling options (Schedule
can be turned on or off by the
user under Menu > Schedule)
1050
Temperature Indication Scale
1060
Outdoor Sensor
(TH2320 models only)
2000
Heating System Type
2010
Heating Equipment Type
2060
Reversing Valve O/B
INSTALLER MENU
options. When
on the left and the
or
to change the setting
NEXT
SAVE & EXIT
button; this will save your
ISU Options (factory defaults are in bold)
1 = 1 week (all days the same)
2 = 5-2 Programmable (separate weekdays and
3 = 5-1-1 Programmable (separate Saturday and
4 = 7-Day Programmable (each day separate)
F = Fahrenheit
C = Celsius
0 = None
1 = Wired Outdoor Sensor
2 = Internet Weather (TH2320WF)
1 = Conventional Forced Air Heat
2 = Heat Pump
3 = Radiant Heat
5 = None (Cool Only)
Conventional Forced Air Heat:
1 = Standard Efficiency Gas Forced Air
2 = High Efficiency Gas Forced Air
3 = Oil Forced Air
4 = Electric Forced Air
5 = Hot Water Fan Coil
Heat Pump:
7 = Air to Air Heat Pump
8 = Geothermal Heat Pump
Radiant Heat:
9 = Hot Water Radiant Heat
12 = Steam
0 = O (O/B on Cool. O wire is
connected to the O/B terminal
and controls cooling.)
1=B (O/B on Heat. B wire is connected to the O/B
terminal and controls heat.) The literature that
came with your pump equipment should indicate
whether the reversing valve is energized in Heat or
Cool mode.
12
button for 5
ISU
ISU setting
on
to advance
weekend)
Sunday)
Need help?