AC Infinity AIRTITAN Series, AIRTITAN T3 / T7 / T8 Manual

AC Infinity AIRTITAN Series, AIRTITAN T3 / T7 / T8 Manual

Also See for AIRTITAN Series:

Advertisement

AC Infinity AIRTITAN Series, AIRTITAN T3 / T7 / T8 Manual

KEY FEATURES

Key Features Overview

PRODUCT CONTENTS

MOUNTING

  1. Remove any existing grilles, vents, or covers on ventilation opening where you wish to install the fan unit.
  2. Position the fan unit over the ventilation opening. Depending on the model, the unit may be facing towards or away from the wall. Please be sure to check the airflow direction prior to installation.
    Mounting - Step 1 - Position the fan unit
  3. Foundation Block Mounting
    To install the unit onto a foundation brick or block, mark the mounting hole locations using the four corners of the metal face plate. Then drill 5/16" holes with a drill bit. Install wall anchors into openings and secure the unit into the wall with four screws. Note that the models T3 and T7 are designed for cabinet and wall mounting, and do not include wall anchors and larger type screws.
    Mounting - Step 2 - Foundation Block Mounting
    Wall and Surface Mounting
    If installing the unit onto a cabinet, wall, wood header, rim joist, or mesh on an existing crawl space vent, please use the unit or plastic template to determine the mounting location. Secure the mounting frame onto the surface with the included wood screws. If using a machine screw with nuts, you may need to drill a hole. Note that models T8 and T8-N do not include a plastic template.
    Mounting - Step 3 - Wall and Surface Mounting

POWERING

AIRTITAN T8 T8-N

  1. To set up temperature monitoring, plug the male connector of the thermal probe into the designated probe port located at the bottom side of the fan unit.
    Powering - AIRTITAN T8 T8-N - Step 1
  2. To power the unit plug in the power, plug the male connector of the corded power adapter into the designated power port located at the bottom side of the fan unit. Then plug the adapter head into an outlet.
    Powering - AIRTITAN T8 T8-N - Step 2

AIRTITAN T3 T7

  1. Plug the fan's male molex connector into one of the two designated probe ports located at the bottom side of the controller.
    Powering - AIRTITAN T3 T7 - Step 1
  2. To power the unit plug in the power, plug the male connector of the corded power adapter into the designated power port located at the bottom side of the controller. Then plug the adapter head into an outlet.
    Powering - AIRTITAN T3 T7 - Step 2

PROGRAMMING

Programming

  1. MODE BUTTON
    This button cycles through each of the controller's modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings).
  2. UP/DOWN BUTTON
    The up and down buttons adjusts the settings of the mode that you are in. Up button increases and down button decreases.
  3. LEAF BUTTON
    This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display.
  4. PROBE TEMP.
    Displays the current temperature that the corded sensor probe is measuring. Shows "- -" if no probe is plugged in.
  5. CONTROLLER MODE
    This area displays the mode that the controller is currently in. Press the Mode Button to cycle through the modes.
  6. ALERT ICONS
    This area displays the alerts and statuses from the controller including alarms and screen lock.
  7. PROBE HUMIDITY
    Displays the current humidity that the corded sensor probe is measuring. Shows "- -" if no probe is plugged in.
  8. FAN SPEED
    Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in.
  9. SETTING
    Displays the value you have set for the current mode. Press the up or down button to change.

MODE SETTING

Press the Mode button to cycle through the controller's available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings).

ON MODE
In this mode, the fans will run continuously regardless of temperature or humidity. The speed set in this mode will be the max speed the fans can reach in AUTO Mode.

OFF MODE
In this mode, the fans will not run regardless of temperature or humidity. While in this mode, pressing the up or down button will change the display's brightness. There are four settings for brightness, (Setting: 1/2/3/A3). On setting A3, if the device is left unattended for 30 seconds, the display will automatically dim its brightness back to setting 1. Holding up or down button will change the display's units F or C.

TIMER MODE
In this mode, press the up or down button to set a time for the timer. The fans will run at the speed set in ON Mode until the timer's clock runs out, in which the fans will stop running. The clock will begin counting down if no buttons are pressed for 3 seconds. Leaving the timer mode while the countdown is running will pause the clock until you return to this mode.

AUTO MODE: HIGH TEMP.
In this mode, press the up or down button to set a high temperature trigger. The fans will activate if the probe's measured temperature exceeds the temperature you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured temperature falls below your set temperature, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF for off. Note that this trigger can activate to run as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.

AUTO MODE: LOW TEMP.
In this mode, press the up or down button to set a low temperature trigger. The fans will activate if the probe's measured temperature falls below the temperature you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured temperature rises above your set temperature, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF for off. Note that this trigger can activate to run as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.

AUTO MODE: HIGH HUMID.
In this mode, press the up or down button to set a high humidity trigger. The fans will activate if the probe's measured humidity exceeds the humidity you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured humidity falls below your set humidity, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF for off. Note that this trigger can activate to run as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.

AUTO MODE: LOW HUMID.
In this mode, press the up or down button to set a low humidity trigger. The fans will activate if the probe's measured humidity falls below the humidity you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured humidity rises above your set temperature, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF for off. Note that this trigger can activate to run as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.

ALARM SETTING: HIGH TEMP.
In this settings mode, press the up and down button to set a high temperature alarm. The alarm will activate if the probe's measured temperature exceeds the temperature you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.

ALARM SETTING: LOW TEMP.
In this settings mode, press the up and down button to set a low temperature alarm. The alarm will activate if the probe's measured temperature falls below the temperature you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.

ALARM SETTING: HIGH HUMID.
In this settings mode, press the up and down button to set a high humidity alarm. The alarm will activate if the probe's measured humidity exceeds the humidity you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.

ALARM SETTING: LOW HUMID.
In this settings mode, press the up and down button to set a low humidity alarm. The alarm will activate if the probe's measured temperature falls below the temperature you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.

FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, please set the controller to OFF Mode, then hold the up button for Fahrenheit (°F) or hold the down button for Celsius (°C).

DISPLAY BRIGHTNESS
To adjust the brightness of the display, please set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. Four brightness settings are available.

TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, please press the MODE and UP button simultaneously. This can be done while the controller is any mode or setting. The calibration cycle ranges from -8°F to 8°F (or -4°C to 4°C) and will be applied to the probe sensor's measurements.

HUMIDITY CALIBRATION
To adjust the humidity that the probe sensor is measuring, please press the MODE and DOWN button simultaneously. This can be done while the controller is any mode or setting. The calibration cycle ranges from -8% to 8% and will be applied to the probe sensor's measurements.

CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidently, hold the LEAF button for two or more seconds. While the display is locked, you will not be able to switch modes or changes any settings. You will only be able to put the controller in ECO display by pressing the LEAF button. Holding the LEAF button for two or more seconds will unlock the controller.

ECO-MODE
The controller can be put into ECO display in which the screen will be turned off but all programs, settings, and alarms will be running in the background. This can be done by pressing the LEAF button. You may also do this while the controller is locked. To exit ECO display, simply press any buttons.

ALERT ICONS

On the top left of the display is the alert icon section. Icons may flash when the controller wishes to alert you that a particular function or alarm is being triggered.

DISPLAY LOCK ALERT
This icon is visible when the controller has been locked. The icon will flash to alert you that the controller is locked if you try to change the mode or settings.
HUMIDITY ALARM ALERT
This icon will flash when the high or low humidity alarm that you have set has been triggered.
TEMPERATURE ALARM ALERT
This icon will flash when the high or low temperature alarm that you have set has been triggered.
CHECK FAN ALERT
This icon will flash when the fan's sensor detects interference to its operation. Please check the fan for possible issues. If the fan is rotating, it may just be static pressure resistance and operating as intended. If the fan is not rotating, please see the warranty page for replacement information. (This feature is only available on certain model.)

AIRTITAN FAQ

Q: Can I mount this crawlspace fan vertically?
A: Yes. The AIRTITAN can be mounted in any orientation, including vertically.

Q: Can I splice the cables to extend them or use my own probe?
A: We do not recommend hardwiring or splicing our fan's power wires. Such modifications may compromise electrical safety and will void this product's warranty.

Q: How do I reverse the airflow of my crawlspace fan?
A: To flip the fan blades, unscrew the bolts from the steel plate and the body. Flip the fans within the body and screw the bolts back in.

Q: How far can I mount the controller from the fan?
A: You may mount the controller up to six feet away from the fan, which is the length of the cable.

Q: Does the controller retain its settings after power is shut off?
A: Yes. If the controller's power is cut off and is powered on afterwards, your settings will remain.

Q: Does this fan include grilles for outside installation or duct tubes for wall installation?
A: This product does not come included with ducting or grilles as accessories.

Q: Is this fan waterproof?
A: The AIRTITAN is IP44 rated for resistance against splashing water.

Q: Will this fan help with Radon mitigation?
A: Yes. The AIRTITAN will ventilate your crawlspace to exhaust radon gas emitting from soil.

Q: Do I need to use both an intake and an exhaust model?
A: You will at least need to use an exhaust fan for crawlspace applications. Intake fans are optional.

AC INFINITY PRODUCTS

Register Booster Fans
The AIRTAP series is a line of register booster fans designed to quietly increase airflow coming from your central heat and air conditioning systems, increasing comfort for your home. Features a thermal controller with intelligent programming that will automatically adjust airflow strength in response to heating and cooling temperatures you have set.

Duct Fans
The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV rooms and closets, as well as various DIY air circulation and exhaust projects. Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in response to changing temperatures.

Project Muffin Fans
The AXIAL series fan kit is designed for various DIY projects that requires cooling or ventilation; or as a replacement fan for many products on the market. Each fan kit includes fan guards and everything needed to mount the unit onto a wall and power it through a wall outlet. S-series models include a speed controller.

Discover the latest innovations in cooling and ventilation at acinfinity.com

EMAIL
support@acinfinity.com
WEB
www.acinfinity.com
LOCATION
Los Angeles, CA

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download AC Infinity AIRTITAN Series, AIRTITAN T3 / T7 / T8 Manual

Advertisement

Need help?

Need help?

Do you have a question about the AIRTITAN Series and is the answer not in the manual?

Questions and answers

Table of Contents