8-5.

Error Codes

Code
004
Overtemperature IGBT1
Overtemperature IGBT2
005
Overtemperature Secondary Rectifier
101
Temperature Sensor Fail IGBT1 (Short
Circ)
Temperature Sensor Fail IGBT2 (Short
Circ)
102
Temperature Sensor Fail Secondary 1
(Short Circ)
Temperature Sensor Fail AUX (Short
Circ)
103
Temperature Sensor Fail IGBT1 (Open)
Temperature Sensor Fail IGBT2 (Open)
104
Temperature sensor fail secondary recti-
fier, or Overtemperature on Inductance
(OpenCirc)
45
Trigger Protection
019
Water Cooler Alarm
131
Phase Fail Alarm
130
Low 24 V Alarm
111
Communication with Main Microcontrol-
ler Fail
112
Communication with USB Board Fail
OM-292017 Page 38
Error
Trigger pressed or problem with torch
wiring during turning on of the machine
Cooler signals a malfunction due to no
liquid.
Cooler is enabled but not connected.
Machine signals a missing phase.
Machine signals a low internal voltage.
Logic problem: error during update or
fault logic
USB board fault or USB board not
installed.
Description
Unit overheated. Allow unit to cool. See
Section 3-6.
Contact a factory authorized service
agent.
Unit overheated. Allow unit to cool. See
Section 3-6. If problem persists, contact
a factory authorized service agent.
Check torch and torch wiring. Refer to
torch owner's manual.
Add more coolant.
Check connections to cooler.
Check for proper input power connec-
tions. See Section 4-10.
Check input line voltage.
Contact a factory authorized service
agent.
Contact a factory authorized service
agent.
Remedy