Sebo AUTOMATIC X7, AUTOMATIC X7 Premium, AUTOMATIC X8 - Vacuum Cleaner Manual

Sebo AUTOMATIC X7, AUTOMATIC X7 Premium, AUTOMATIC X8 - Vacuum Cleaner Manual

Also See for AUTOMATIC X7:

Advertisement

Contents
Sebo AUTOMATIC X7, AUTOMATIC X7 Premium, AUTOMATIC X8 - Vacuum Cleaner Manual

TECHNICAL DETAILS

Vacuum motor 120 volts (12 amps)
Water lift (at motor) 91.5 inches
Airflow (at motor) 100.2 CFM
Filter bag capacity 1.4 gal.
Sound level 69 dBA
Body weight X7-16.7 lbs / X8-16.9 lbs
Motor protection electronic cut-out
Working width X7-12 inches / X8-15 inches

WIRING DIAGRAM

WIRING DIAGRAM

SEBO AUTOMATIC X PRODUCT FEATURES

Designed for All Floor Surfaces.
Automatic Height Adjustment for All Floors
– Based upon the resistance of the brush roller against the floor, the power head automatically adjusts up or down to the appropriate cleaning height, providing optimal cleaning of all floor surfaces. The height adjustment chosen by the machine ensures aggressive brush action, while providing optimal air flow. This prevents suffocation of air flow due to improper height selection. Never again manually adjust the brush height or use different vacuums for various floor surfaces; the SEBO X cleans them all, automatically!

Brush Adjustment Indicator Lights – Two lights, one for "up" and one for "down," illuminate to indicate when the brush roller is in the process of adjusting to the proper cleaning height. Optimum cleaning occurs when both lights are off.

Bag Full or Clog Light & Auto Shut Off – A warning light will illuminate and the machine will automatically shut off, when it senses a full bag, a clog in the airflow pathway, or an excessively dirty micro filter. If the user ignores this warning for approximately 30 seconds, the machine will shut off and the "BAG FULL OR CLOG" light will flash. The user should turn the switch off, unplug the machine and immediately insert a new bag or remove the clog (to remove a clog, refer to the Clog Removal section). If the user restarts the machine without having solved the problem, the "BAG FULL OR CLOG" light will again illuminate and the machine will shut off in 30 seconds. This feature prevents damage to the motor due to overheating.

Brush Deterioration Light – To ensure optimum cleaning at all times, a warning light will illuminate to indicate when the brush roller should be replaced due to excessive wear. The red "CHECK BRUSH" light will illuminate (after a 10 second delay) to notify the user that the brush roller is too worn and, therefore, should be replaced. The light will remain illuminated until the worn brush roller is replaced, but the machine will continue to operate.

Brush Obstruction Light & Auto Shut Off – A warning light will quickly flash, the brush roller will immediately stop spinning and the vacuum will shut off, if an obstruction becomes jammed in the brush roller. This prevents the belt from breaking and protects the motor from damage. The user should turn the switch off, unplug the machine and immediately remove the obstruction. If the user restarts the machine without removing the obstruction, the machine will again shut off in 3 seconds and the "CHECK BRUSH" light will flash.

Stationary Use Light – A warning light will slowly flash when the machine is standing in its upright locked position (which causes the power head to rise to its highest point from the floor) yet the brush remains in contact with the carpet fibers. This feature warns of potential carpet damage caused by excessive time in a stationary position, during which carpet fibers remain engaged with the brush, usually on medium to high pile carpet.

LED Head Lamp* - This feature provides illumination for the dark areas of a room.

* depending on model

Easy Brush Roller Removal – Quick brush cleaning or replacement is easy, and no tools are required!

Vacuum Motor – The AUTOMATIC X has a 1300 watt motor.

Instant-use Wand and Suction Hose – The integrated instantuse cleaning wand or suction hose is always ready. Just pull out either tool, or both together, to clean hard-to-reach corners, edges and crevices. The suction hose is ideal for cleaning furniture. And an optional nine-foot extension hose is available, which creates a total hose length of 15 feet, perfect for cleaning stairs. Choose from a range of optional attachments that can be fitted to the cleaning wand or hose. The wand and hose together have an eight-foot reach for instant cleaning of hard-to-reach areas.

A Flat-to-the-floor, 6-inch Profile – Such a low profile makes cleaning under furniture and beds easy!

Forty-foot Cord – A 40-foot cord saves time because it minimizes the number of electrical outlets needed during use.

Lifetime Belt Warranty - No more changing belts...they should last the life of the machine!

Two Power Head Widths – The AUTOMATIC X7 power head is 12 inches wide, with a cleaning width of 10½ inches. The AUTOMATIC X8 power head is 15-inches wide, with a cleaning width of 14½ inches.

Three On-board, Full-size Tools and Large Filter Bag – The vacuum comes standard with a crevice nozzle, dusting brush and upholstery nozzle. Many optional accessories are also available. The filter bag is also SEBO's largest, with a dirt capacity of 1.4 gallons.
Overview

STANDARD FEATURES OF ALL SEBO VACUUMS

SEBO's FILTRATION SYSTEM:

Bagged vs. Bagless. . . Bags are Better! – Top-fill, three-layer AeraPure™ bags are an integral part of SEBO's filtration system because they hold virtually all the dirt captured by the vacuum, which improves the effectiveness and useful life of the microfilters. They also ensure continuously strong suction because dirt enters from the top, deposits at the bottom, accumulates upward, and air exits through the sides, which allows unimpeded airflow as they fill to capacity. And they can be tightly sealed with a hygiene cap when full, so no dust can escape into the air during bag removal and disposal.

In contrast, without bags to hold nearly all the captured dirt, the microfilters on bagless vacuums quickly clog from excessive dirt build-up and must be replaced often, or a loss of suction and cleaning effectiveness will occur. In addition, dust and other allergens become airborne when emptying bagless dirt containers. Lastly, bagless vacuum microfilters are expensive, usually costing more than a multi-year supply of SEBO filter bags.

S-class, Pre-motor and/or Exhaust Microfilters

S-class, Pre-motor and Exhaust Microfilters (S ="Schwebstoff" = airborne particles) are made from electrostatically charged, microfiber material, which attracts and captures dust particles from the airflow of the vacuum before and after it passes over the motor to cool it. Cooling the motor with super-clean air increases motor life and reduces the possibility of maintenance, even after many years of use. Also, the exhaust air is cleaned to the highest level before being emitted from the machine. The S-class Standard requires filters to absorb greater than 99.9% of particles down to 0.3 microns in diameter. For comparison, 100 microns is the diameter of a human hair. Their advantages are a relatively open texture that allows smoother airflow for better suction performance, a longer life expectancy, and they cost less than HEPA filters.

HEPA, Pre-motor and/or Exhaust Microfilters (Optional) – HEPA Microfilters ("High Efficiency Particulate Air") remove a minimum of 99.97% of all airborne particulate matter down to 0.3 microns in diameter. Because these filters use small, gridlike structures to capture dust particles, dirt build-up clogs the airflow pathway sooner than what is expected from S-class microfilters. However, SEBO's HEPA microfilters are sold along with three-layer AeraPure™ bags, which provide highly effective filtration before the airflow goes through the HEPA microfilter, greatly increasing life expectancy and reducing the potential of diminished air flow.

Designed and Manufactured in Germany – Legendary quality, reliability and performance make SEBO vacuums the first choice of cleaning professionals throughout the world.

World's Best Pet Vacuums – Because of superior power-head and brush-roller technology, SEBO vacuums are the world's best for pet hair removal!

Tightly Sealed Vacuums Ensure Effective Filtration – Dirty air, which flows through a vacuum, can only be filtered completely if it does not escape into the room through seams or seals in the machine. This is why all SEBO vacuums have tight seals throughout.

Many vacuum companies with high-filtration claims are actually quoting specifications made by the manufacturer of the filter material, as measured in the laboratory, not the filtration effectiveness of the vacuum itself while operating. Whether or not dirty air can escape through leaks in the body of the machine is not considered. The filtration effectiveness of SEBO vacuums is tested while they operate.

Reliable, Commercial-grade Components – All SEBO vacuums are constructed with thick, reinforced, ABS plastic, aluminum and metal parts, steel axles and bearings, and high-end, quality motors. Therefore, SEBO users own reliable, long-lasting vacuum cleaners. Competing vacuums are made with thin, flimsy, inexpensive, plastic materials, none of which are reinforced, and typically have useful lifespans of one or two years.

Rubber Wheels and Soft Bumpers Protect Homes – Smoothgliding, rubber wheels protect hard floors and provide exceptional maneuverability. In addition, the bumpers that surround the power heads and the soft AIRBELT bumpers that surround SEBO's canisters protect furniture, walls, and vacuum housings from incurring scuffs and scratches during use.

Advanced, Brush-Roller Technology – SEBO's brush rollers are uniquely designed to funnel hair and debris into the power head's airflow channel, which improves vacuum cleaning performance on all flooring surfaces.

Changing Bags is Easy and Clean – SEBO filter bags can be changed in just a few seconds, and a hygiene cap keeps dust sealed inside during removal and disposal.

Save Money! SEBO Vacuums Last for Years and Extend Carpet Life! – If properly maintained, SEBO vacuums save ordinary, residential users hundreds of dollars, by providing excellent performance for ten to fifteen years or more, and their deepcleaning, power-brush technology extends the life of carpets. Typical vacuums perform poorly, even when new, and usually do not last beyond two years. So six or seven "disposable vacuums" must be purchased during the average life expectancy of just one SEBO machine.

Incredible Warranty Coverage – All SEBO models include a FREE seven-year warranty on the motor and five-years on nonwear parts and labor charges.

OPTIONAL ATTACHMENTS, ACCESSORIES, BAGS & FILTERS

In addition to the standard on-board tools, a variety of optional attachments are available. The 9' 2"extension hose (extends suction hoses) and the 22" extension wand (extends instant-use wands) are very popular because they create useful tools for cleaning stairs and out-of-reach areas. These two items are sold separately or as part of multiple item attachment kits.

Another popular attachment is the hand-held turbo brush for removing pet hair from upholstery. SEBO AeraPure™ filter bags can be purchased in boxes of eight and filters are sold separately. SEBO bags, filters and accessories are reasonably priced and widely available. To create a fresh scent while vacuuming, SEBO FRESH is available. To use, deposit a scented stick in the filter bag.
OPTIONAL ATTACHMENTS, ACCESSORIES, BAGS & FILTERS

IDENTIFICATION OF PARTS

IDENTIFICATION OF PARTS

  1. Handle grip
  2. On/Off switch
  3. Handle assembly
  4. Cleaning wand handle
  5. Handle catch
  6. Retaining ring
  7. Cover release flap
  8. Front cover
  9. Carrying handle
  10. Housing release button
  11. Brush roller release button
  12. Head lamp*
  13. Power head with brush
  14. Display
  15. Bag housing
  16. Cable (cord)
  1. Upper cable (cord) hook
  2. Attachment hose
  3. Cable (cord) hook
  4. Carrying handle
  5. Cleaning wand (active wand)
  6. Crevice nozzle
  7. Upholstery nozzle
  8. Foot pedal
  9. Exhaust filter cover
  10. Dusting brush clamp
  11. Dusting brush
  12. Swivel neck
  13. Support lever
  14. Connecting tube
  15. Protruding tab
  16. Hose release button

*Depending on model

Standard Attachments

  1. Crevice nozzle
  2. Upholstery nozzle
  1. Dusting brush clamp
  2. Dusting brush

ASSEMBLY

ASSEMBLY

Place the power head (13) on the floor with the swivel neck (28) and the support lever (29) upright. Hold the bag housing (15) vertically and place it over the swivel neck (28) and support lever (29). Push firmly and evenly down so that the housing release button (10) snaps outward to its "locked" position.

Slide the dusting brush clamp (26) onto the handle tube and tighten the screw. The handle of the dusting brush (27) will now snap into the clamp.

To lock the handle (3) to the bag housing (15), turn the handle catch (5) at the handle joint of the bag housing (15) forward to "open" position. Then slide the handle assembly (3) in as far as possible and lock it in by turning the handle catch to the closed position.

Push the black end of the attachment hose (18) into the connecting tube (30) so that it clicks into place. Insert the cleaning wand (21) into the swivel neck (28) and push the handle (4) over the protruding tab (31).

Insert crevice nozzle (22) and upholstery nozzle (23) into the recesses in the back of the machine.

NOTE: All illustrations shown in this manual represent the X7 model except where part numbers and instructions are different for each model. In those instances, illustrations for both the X7 and X8 will be shown.

OPERATING INSTRUCTIONS

Starting The Machine

Figures 1 & 2
Starting and Operating The Machine
Before turning on your vacuum cleaner, make sure that the vacuum handle is in its upright locked position and that you have a firm hold on the handle grip to keep the machine from moving forward.

  1. Turn the quick release cable hook (#19, figure 1) to the up positionby moving it to the left or right.
  2. Release the power cord plug from the power cord and lift the cord off of the upper cord hook (#17, figure 2).
  3. With the switch (#2, figure 2) in the "O" (OFF) position, plug the polarized power cord into a 120 volt outlet located near the floor.

Switch Position
O = OFF
I = ON

NOTE: The AUTOMATIC X is equipped with a soft start system. The gradual power-up extends vacuum life.

Operating the Machine

Figure 3

When the machine is switched on with the handle in the upright locked position, the power head and brush automatically rise from the carpet. To release the machine from the upright locked position, press down on the foot pedal (24) and lower the handle into the normal operating position. The power head and brush will automatically lower to the appropriate height.

Using the Cleaning Wand, Hose & Attachments

Using the Cleaning Wand, Hose & Attachments

The cleaning wand (21) is useful for vacuuming corners and hard-to-reach areas. The handle grip (1) should be in the upright, locked position (as shown in figure 4). Grip the Figure 3 cleaning wand handle (4), pull it up and away from the machine and stretch out the hose (18) until it locks to the back of the tube (this locking action will prevent the hose from retracting back into the cleaning wand while it is in use). Various attachments may be inserted onto the end of the tube. After use, remove attachment and re-insert the cleaning wand into the back of the machine. Be sure that the cleaning wand handle (4) is inserted over the protruding tab (31) as shown in figure 6. If the cleaning wand handle is properly seated over the protruding tab, the hose will automatically retract and you may resume vacuuming. There is no need to turn off the vacuum while switching from upright vacuuming to using the cleaning wand or hose.


The quality, condition, coating, texture, age and manufacturing technique of all floor surfaces vary.
Therefore, upright vacuums with rotating brushes, including your SEBO, may damage some floor coverings or surfaces. Some types of high-gloss hardwood floors, cushion vinyl, berber carpets, long shag, and delicate or hand-woven carpets are particularly vulnerable to damage by rotating brushes. When possible, consult the materials supplied by your floor's manufacturer for information on proper upkeep and cleaning. To ensure that your new SEBO vacuum cleaner is compatible with your floor, please test the vacuum cleaner on each type of flooring surface in a small inconspicuous area to determine if any damage occurs. If damage occurs, stop using the vacuum cleaner immediately! The standard brush roller on your SEBO vacuum is appropriate for most types of floor surfaces. However, a soft-bristle brush roller (X7 part # 5010GE or X5 part # 5290GE) that is designed for use on sensitive looped-pile carpets and/or hard floors is available for an additional charge. As with the standard brush roller, you should test the machine using the soft-bristle brush roller in an inconspicuous area prior to widespread use. The soft-bristle roller will wear more quickly than the standard brush roller, so it will need to be replaced more often. Also, because the bristles are softer, the height adjustment on the machine will be slightly lower than normal. Care must be taken to ensure that the bottom of the machine does not contact the floor. If this happens, damage to the floor could occur. If damage occurs, stop using the vacuum cleaner immediately!

To use the hose without the cleaning wand (as shown in figure 5), pull the hose out of the cleaning wand while the tube is still attached to the machine and securely seated over the protruding tab (31 figure 6). Insert an attachment tool, if desired, onto the end of the flexible hose. You may also release the hose while the cleaning wand is disengaged from the machine by pressing the hose release button (32) at the base of the cleaning wand handle (4).

While using attachment tools, if the power head brush roller is not able to disengage from the floor surface, the stationary-use warning light will flash. You may keep the brush roller off the carpet by placing the handle (1) in its upright locked position and lowering the handle with one hand to raise the brush roller off of the floor. Operate attachment accessories with the other hand. Or, with the handle in the upright locked position, the machine may be tipped backward so that it rests against furniture or the floor on the back side of the bag housing (15), and the power head is locked in a perpendicular position to the floor. Ensure that no children or pets can come into contact with the spinning brush roller.

To vacuum walls, under beds, or higher-reach areas, etc., the SEBO AUTOMATIC X can be fitted with an optional straight tube (33) and the optional wall and floor brush (34). The machine will then perform as a canister vacuum (as shown in figure 7).

The Display Panel


Green light (a): Brush is lowering

Green light (b): Brush is rising

Red light (c): Flashing and motor off - brush jammed – clear jam

Red light (c): Flashing and motor on (when machine is in upright, locked position) – Take care, brush in contact with carpet

Red light (c): Continuous – change brush roller

Red light (d): Continuous – change bag or clear clog

Red light (d): Flashing – motor switched off due to full bag or clog

Boost Function (X7 Premium and X7 Premium Pet)


For high energy efficiency and deep cleaning of the carpet, the SEBO AUTOMATIC X7 Premium and X7 Premium Pet vacuums are equipped with a boost button (35). Press the button (35) by hand to activate the boost function. Once activated, the button will illuminate green. To deactivate the boost function, press the boost button again.

NOTE: The boost function will be automatically deactivated when the machine is turned off. After switching on the machine again, the boost function has to be activated separately.

* Depending on model

The Adjustment Wheel


On hard floors (figure 10), the adjustment wheel (36), moves upward into the machine so that the brush lowers and becomes flush with the floor.

On carpeted floors (figure 11), the adjustment wheel (36) moves downward out of the machine so that the brush rises. The adjustment wheel moves up and down automatically to adjust the brush to the correct setting. This provides aggressive brush action, while maintaining optimal air flow.

VACUUM MAINTENANCE

warning Always unplug vacuum from outlet before dismantling any part of machine!!

Changing the Filter Bag

Figures 12 & 13
Changing the Filter Bag and Pre-motor Microfilter
To change the filter bag (37), pull the cover release flap forward (7) and lift the front cover (8) from the bag housing. The cover release flap must remain in a forward "pulled-out" position to change filter bags and SEBO lock them into place. Squeeze the clamps on both sides of the filter bag sealing plate (38), slide the plate from the holder (39) and push the cap (40) on to seal the bag. Slide the sealing plate (38) of a new bag into the holder and push it in firmly. Re-insert cover into bag housing, push it forward, then lock it in place by pushing down the cover release flap. You may find it convenient to store the bag cap inside the bag housing below the filter bag.

Changing the Pre-motor Microfilter

Figures 12 & 14

The pre-motor microfilter (40) needs to be changed when it becomes extremely dirty or clogged with dust, or after approximately 20 filter bags have been used. To change the pre-motor microfilter, pull the cover release flap (7) forward and lift the cover (8) from the filter bag housing. Then, slide the filter out at the bottom. To replace, lift the safety lever (41) and slide the new filter in using the tracks as guides.

Changing the Exhaust Microfilter

Changing the Exhaust Microfilter
After 20 bags have been used, change the exhaust filter (42). To remove the exhaust filter, squeeze the filter door release buttons (43) toward the middle and remove the filter cover (25). Unhook the filter tab (A) from the catch (B) and pull the filter out. Slide the closed end of the new filter into the machine. Fit filter opening (C) to the air channel (D) and lock the filter tab (A) onto the catch (B), making sure it is smooth and flat. The correct positioning of the filter can be checked by looking through the slots (E) on the front of the powerhead. Slide the filter cover (25) into the top of the opening and move it downward until it clicks into place.

Changing the Brush Roller(s)

Changing the Brush Roller(s)
To change the brush roller(s) (45, 45a), push the brush roller release button(s) (11, 11a), remove the side plate(s) (44, 44a), turn the brush(s) clockwise a quarter of a turn, and pull the old brush roller(s) out. Slide the new brush roller(s) into the brush housing and turn it until it locks into position. While slightly pushing the button(s) (11, 11a), press the side plate(s) (44, 44a) back into the locked position.

Changing the Sealing Strip

Changing the Sealing Strip
The sealing strip (46) is located just behind the brush roller opening. The sealing strip seals the power head to hard floors to prevent kick-back of debris while vacuuming. To replace a worn sealing strip, push the brush roller release button(s) (11, 11a), remove the side plate(s) (44, 44a) and slide the old strip out. Insert the new strip into the slot and slide into place.

CLOG REMOVAL

warning Always unplug vacuum from outlet before removing any clogs!

Clogs in the Airflow Pathway


Most clogs can be removed by accessing the airflow pathway via the orange colored access door (48) located on the underside of the power head. However, other clogs may only be removed by accessing the airflow pathway by disassembling the machine in the opposite sequence of the machine's original assembly (see assembly).

Clogs in the Attachment Hose


Blockages in the hose can be cleared by removing the attachment hose (18) from the machine by squeezing the retaining ring (6) and inserting the opposite end of the hose in the connecting tube (30). Hold the hose upright with one hand blocking the top end and switch on the machine. If necessary, quickly lift your hand on and off the end of the hose. If this procedure does not clear the clog, a straight wire can be inserted into the hose to push out the clog. Take care not to puncture the hose with the wire.

Clogs in the Cleaning Wand (Active Wand)


Remove attachment hose (18) from the cleaning wand (21). Then, grip cleaning wand handle (4) and remove tube from the machine. A straight wire can be inserted into the tube to push out the clog.

Clogs in Entrance to Filter Bag


Remove attachment hose (18) from vacuum cleaner (see figure 20) and remove front cover (8). Clean out connecting tube (30) and/or entrance to bag (49).

Clogs in the Swivel Neck


Clogs in the swivel neck (28) can be removed by first pressing the housing release button (10) and lifting off the bag housing (15). Lift upward firmly and evenly to properly remove the bag housing. Then, release the foot pedal (24), lower the swivel neck, check inside the swivel neck channel closest to the foot pedal (see arrow), and clean out pathway.

TROUBLE-SHOOTING GUIDE

warning Always unplug vacuum from outlet before dismantling any part of the machine!
PROBLEM REASON SOLUTION

Does not turn on or machine shuts off intermittently

1. Handle not fully inserted into the bag housing, causing a faulty connection. 1. Release handle catch, push handle down, close handle catch.
2. Not plugged into good outlet. 2. Use another outlet.
3. Cable worn. 3. Replace cable.
4. Bag housing (15) not seated fully into proper "locked" position on top of power head. 4. Housing release button (10) should be snapped outward to its locked position.

Bag full or clog light on or flashing & machine shuts off

1. Bag full. 1. Replace bag. See Bag Replacement
2. Clog in airflow pathway, attach- ment hose, cleaning wand, swivel neck or entrance to filter bag. 2. See Clog Removal.
3. Microfilter dirty. 3. Replace microfilter.

Brush light on

1. Brush worn. 1. Replace brush.

Brush light slowly flashing

1. Vacuum is stationary and in upright locked position. 1. See OPERATING INSTRUCTIONS

Brush light flashing & machine shuts off

1. Brush jammed. 1. Shut off the power switch, unplug the machine and pull the obstruc- tion from the brush roller.

Up & down lights flicker

1. Operating on uneven floor. 1. Ignore.

Does not pick up

1. Cleaning wand not properly inserted. 1. Reinsert cleaning wand, making sure lower end of tube is in the lower hole and handle is properly seated over the protruding tab (31).
2. Front cover not closed. 2. See below.

Front bag door won't fully close

1. Cover release flap not fully closed. 1. Reinsert bag. Lock the cover release flap down firmly.
2. Bag not inserted properly 2. Reinsert bag with cover release flap (7) up, until firmly latched in bag holder.
3. Microfilter not properly inserted. 3. Lift safety lever and insert filter with vertical plastic ridge on filter facing you.

Hose doesn't retract after cleaning wand is inserted

1. Cleaning wand not properly inserted. 1. Reinsert making sure top of handle is pointing back and tube is fully seated on the protruding tab (30) on top of the bag housing. See figure 6.

AUTOMATIC X7 | X7 PREMIUM | X8 SCHEMATIC AND PARTS LIST

#91542AM AUTOMATIC X7 Premium - Arctic White (white/gray black)
#91543AM AUTOMATIC X7 Premium - Graphite (gray black/silver)
#91540AM AUTOMATIC X7 Premium PET - Black (black/silver)
#91503AM AUTOMATIC X7 - Red (dark red/silver)
#91566AM AUTOMATIC X8 - Blue (dark blue/silver)
SCHEMATIC AND PARTS LIST

Bag Housing and Handle
#91542AM AUTOMATIC X7 Premium Arctic White Machine

Pos. Part # Description

  1. 5642AM Handle complete, gray black/white
  2. 5297GSAM Handle grip, gray black, incl. pos. 7+9
  3. 5359GS1 Grommet
  4. 5450DG Power supply cord
  5. 05113 Switch w/screws
  6. 5160WE Switch cap, white
  7. 5161GS Switch cap holder, gray black
  8. 5162 Cable clamp
  9. 5253UL Wire-antistatic
  10. 5298ER Handle cable
  11. 5187 Handle tube X
  12. 5040SB Hose X, cpl., silver
  13. 5045GS Cleaning wand, gray black
  14. 51059GS Cover, gray black
  15. 5319 Bag holder spring
  16. 5091 Safety catch spring
  17. 5360 Safety catch
  18. 5324 Bag holder cpl., incl. pos. 16+17
  19. 51053SB Cover release, silver
  20. 51052SB Handle cover, silver
  21. 51051WESB Front cover complete, white
  22. 51050WEUL Bag housing X, cpl., white
  23. 5380GS Internal cover cpl., gray black incl. pos. 36+37
  24. 1073 Clamp
  25. 5208 Filter safety catch
  26. 5210 Return spring
  27. 5164 Cable clamp
  28. 51003SB Bag housing locking catch, silver
  29. 1859SB Handle catch, silver
  30. 5721WE Carrying handle, white
  31. 5703WE Cable hook, white
  32. 5146 Stop spring
  33. 5424SB1 Retaining ring, silver
  34. 5299ER Internal cable
  35. 5266 Cable clamp
  36. 5842 Seal
  37. 5289 Seal
  38. 1823GS Attachment clip, gray black
  39. 5084 Spring for locking rod
  40. 5083 Locking rod
  41. 51002WE Bag housing bumper base, white
  1. 1092GS Crevice nozzle, gray black
  2. 1491GS Upholstery nozzle
  1. 0102 Screw F 3.9x13 DIN 7981
  2. 0103 Screw C 3.9x16 DIN 7981
  3. 0129 Screw M 4x12
  4. 0161 Clip 4, DIN 6799
  5. 01036 Screw 4x14, Torx 20
  6. 5460GS Mounting clip with screw
  7. 1387GS Dusting brush
  1. 5093AM AeraPure™ filter bag pack
  2. 5036AM Pre-motor microfilter

#91566AM AUTOMATIC X8 Blue Machine Exceptions

  1. 5644AM Handle complete, gray black/silver
  1. 5160SB Switch cap, silver
  1. 51051DBSB Front cover cpl., dark blue
  2. 51050DBUL Bag housing cpl., dark blue
  1. 5721DB Carrying handle, dark blue
  2. 5703DB Cable hook, dark blue
  1. 51002DB Bag housing bumper base, dark blue

#91543AM AUTOMATIC X7 Premium Graphite Machine Exceptions

  1. 5644AM Handle cpl., gray black/silver
  1. 5160SB Switch cap, silver
  1. 51051GSSB Front cover cpl., gray black
  2. 51050GSUL Bag housing cpl., gray black
  1. 5721GS Carrying handle, gray black
  2. 5703GS Cable hook, gray black
  1. 51002GS Bag housing bumper base, gray black

#91540AM AUTOMATIC X7 Premium PET Black Machine Exceptions

  1. 5640AM Handle complete, black/silver
  2. 5295AM Handle grip black, incl. pos. 7+9
  3. 5359SW1 Grommet, black
  1. 5160SB Switch cap, silver
  2. 5161SW Switch cap holder, black
  1. 5045SW Cleaning wand, black
  1. 51051SWSB Front cover cpl., black
  2. 51050SWUL Bag housing X cpl., black
  3. 5380SW Internal cover, incl. pos. 40+41
  1. 5721SW Carrying handle, black
  2. 5703SW Cable hook, black
  1. 1823SW Attachment clip, black
  1. 51002SW Bag housing bumper base, black
  1. 1092SW Crevice nozzle, black
  2. 1491SW Upholstery nozzle, black
  1. 6179ER Hand-held turbo brush
  2. 1495AM Extension hose
  3. 5425AM Pre-motor anti-odor microfilter

#91503AM AUTOMATIC X7 Red Machine Exceptions

  1. 5645AM Handle cpl., gray black/dark red
  1. 5160SB Switch cap, silver
  1. 51051DRSB Front cover cpl., dark red
  2. 51050DRUL Bag housing cpl., dark red/gray black
  1. 5721DR Carrying handle, dark red
  2. 5703DR Cable hook, dark red
  1. 51002GS Bag housing bumper base, gray black

AUTOMATIC X7 SCHEMATIC AND PARTS LIST

AUTOMATIC X7 SCHEMATIC AND PARTS LIST

AUTOMATIC X7 PREMIUM SCHEMATIC AND PARTS LIST

AUTOMATIC X7 PREMIUM SCHEMATIC AND PARTS LIST

AUTOMATIC X8 SCHEMATIC AND PARTS LIST

AUTOMATIC X8 SCHEMATIC AND PARTS LIST

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

warning When using an electrical appliance, basic precautions must always be followed.

To reduce the risk of electric shock, this vacuum cleaner has a polarized plug; one blade is wider than the other. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Connect only to the outlet type specified on the serial number plate underneath the machine.


To reduce the risk of fire, electric shock, or injury:

  1. Do not leave vacuum while plugged in. Unplug from outlet when not in use and before servicing.
  2. Do not use outdoors or on wet surfaces.
  3. Do not use near small children or pets. Do not allow to be used as a toy. Use of this product by children should always be supervised by an adult.
  4. Use only as described in this manual. Use only manufacturer-recommended attachments.
  5. Do not use with a damaged cord or plug. If vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a SEBO service center.
  6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run vacuum over cord. Keep cord away from heated surfaces.
  7. Do not unplug by pulling on cord. To unplug, grasp the plug – not the cord.
  8. Do not plug in if switch is in the "I" (ON) position.
  9. Do not use outlets above counters to plug in vacuum – damage to items in the surrounding area could occur.
  10. Always carry the vacuum over steps and sills.
  11. Do not handle plug or vacuum handle with wet hands.
  12. Do not put any object into vacuum openings. Do not use machine with any openings blocked. Keep openings free of lint, hair, and anything that may reduce air flow.
  13. Do not re-use filter bags or wash the filters.
  14. Do not remove any screws from vacuum.
  15. Do not vacuum up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  16. Do not use vacuum without filter bag and/or filters in place.
  17. Turn off all machine controls before unplugging.
  18. Use extra care when cleaning on stairs.
  19. Do not use machine to vacuum up flammable or combustible liquids such as gasoline or use in areas where they may be present.
  20. Machines can cause a fire when operated near flammable vapors or materials. Do not operate this vacuum near flammable fluids, dust or vapors.
  21. Maintenance and repairs must be done by qualified personnel.
  22. Use only original SEBO replacement parts.
  23. Do not use vacuum as a step.
  24. If vacuum is used on plush carpet or carpet with thick padding, do not leave machine standing in one place with machine turned on.
  25. Do not use the operator's handle, which inserts into the top of the bag housing, to carry the machine. The carrying handle is located on the backside of the machine's bag housing.
  26. Keep hair, loose clothing, fingers, and all parts of body away from vacuum openings and moving parts. Do not place fingers or other body parts under vacuum unless it is unplugged.
  27. Do not place the power head over rug or carpet edges.
  28. The vacuum has a manual reset thermal protector. The protector is reset by switching off the vacuum. The thermal protector needs some time to cool down after switching off! Check the vacuum for air blockages or mechanical failures before switching on.
  29. Store the vacuum in a dry place at room temperature. When the vacuum is not in use, you should wrap the cord on the cable hooks.
  30. Any other servicing should be performed by an authorized service representative.
  31. Always turn off this appliance before connecting or disconnecting power head with brush.

HOW TO CONTACT SEBO

To contact SEBO in the United States of America:
SEBO America, LLC
Telephone: (800) 334-6614
Fax: (303) 792-9196
Website: www.sebo.us

To contact SEBO in Canada:
SEBO Canada
Telephone: (877) 258-5005
Fax: (800) 270-4807
Website: www.sebocanada.ca

For Warranty coverage information please refer to your Warranty Card included with your SEBO vacuum cleaner.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Sebo AUTOMATIC X7, AUTOMATIC X7 Premium, AUTOMATIC X8 - Vacuum Cleaner Manual

Advertisement

Need help?

Need help?

Do you have a question about the AUTOMATIC X7 and is the answer not in the manual?

Questions and answers

Table of Contents