Alarm Code
Alarm description
7x flash
Overcurrent (short circuit)
Power fuse or on-board contactor
8x flash
damaged
9x flash
Undervoltage
10x flash
Overvoltage
11x flash
Overload protection
12x flash
Disable switch on
13x flash
Key-off sequence detected
14x flash
Internal memory fail
15x flash
No release
Page 32
Description
Wiring
Controller has protected itself, cause of
A1.M(PIN1) at M1.PIN(A2) and
an external short circuit
A1.M2(PIN2) at M1.PIN(A1)
G1.PIN(P) to X0PIN(P) to F1.PIN1/PIN2
Controller detects a failure on the
at A1.PIN (B+) and
external power fuse or power
A1.PIN(B-) to X200 to X0PIN(N) at
connections
G1.PIN(N)
G1.PIN(P) to X0PIN(P) to F1.PIN1/PIN2
Battery voltage lower than value set by
at A1.PIN (B+) and
parameter (< 18V)
A1.PIN(B-) to X200 to X0PIN(N) at
G1.PIN(N)
Battery voltage higher than 45V
A1.M(PIN1) at M1.PIN(A2) and
/
A1.M2(PIN2) at M1.PIN(A1)
A1.X1PIN8 (only if A1.X1PIN5 (24V)) to
K3.PIN86 and K3.PIN85 to A1.X1PIN7
Required feedback: X200 to K3.PIN30
Controller is disabled
Switch.fct. K3.PIN30 to 87a (not switched
=> GND = deactivated); PIN30 to 87
(switched => A1.PIN6 OPEN)
G1.PIN(B+) to X0PIN(B+) to X100 to
F2PIN1/2 to X2PIN1 to S1PIN(BAT)
Switch.fct. S1 PIN(BAT) ... (OPEN);
Key switch was opened
PIN(BAT) to PIN1+2(CLOSED)
S1 to X2PIN3 to F3PIN1/2 at
A1.X1PIN15
/
G1.PIN(B+) zu X0PIN(B+) zu X100 zu
F2PIN1/2 zu X2PIN1 zu S1PIN(BAT)
Schaltfkt. S1 PIN(BAT) ... (OFFEN);
PIN(BAT) zu PIN1+2(GESCHLOSSEN)
No signal from seat contact
S1 zu X2PIN zu F3PIN1/2 zu X1PIN4 zu
(GESCHLOSSEN) zu X5PIN2 zu X1PIN5
Troubleshooting
Check the motor's wires
Check internal motor resistance
If ok and the controller repeats this alarm, change it
If the controller repeats this alarm and the power connections are
o.k., change it
Check battery's charge. Check your parameter settings: if the
controller repeats this alarm, change it
/
Check the battery status
Check the motor power consumption (25A max. 60s long)
Check wiring to A1.X1PIN6
Eliminate reason for deactivation.
Then reset with key switch OFF-ON
Check the key switch wiring
If the controller repeats this alarm, change it
Check wiring of seat contact switch and seat contact switch
X5PIN1 an S5... (OFFEN);
an A1.X1PIN5
IR/KUD/102023