134
The floor load created by the tumble dryer is concentrated and trans-
ferred to the installation surface via the adjustable feet. A base is not
required. However, an uneven floor surface must be compensated
for.
PDR 514/518/522/914/918/922
x
1400 mm
y
906 mm
z
PDR 514/914: 852 mm
PDR 518/918: 1035 mm
PDR 522/922: 1164 mm
To facilitate any future maintenance work, a maintenance corridor
with a width of at least 500 mm must be set up behind the machine
and must be accessible at all times. The distance between the ma-
chine and any walls must not fall below the specified minimum val-
ues.
Adjust the tumble dryer adjustable feet until the machine is level.
Use a spirit level to ensure correct alignment.
PDR 528/544/928/944
1640 mm
1206 mm
PDR 528/928: 1018 mm
PDR 544/944: 1384 mm

Advertisement