National Instruments NI cDAQ-9136 Safety, Environmental, And Regulatory Information
National Instruments NI cDAQ-9136 Safety, Environmental, And Regulatory Information

National Instruments NI cDAQ-9136 Safety, Environmental, And Regulatory Information

Compactdaq four-slot controller with quad-core processor
Hide thumbs Also See for NI cDAQ-9136:

Advertisement

Quick Links

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION
NI cDAQ
NI CompactDAQ Four-Slot Controller with Quad-Core Processor
This document includes compliance precautions and connection information for the
NI cDAQ-9136.
Note
The guidelines in this document are specific to the NI cDAQ-9136. The other
components in the system might not meet the same ratings. Refer to the
documentation for each component in the system to determine the safety and EMC
guidelines for the entire system.
Safety Guidelines
Caution
manual. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to National Instruments for repair.
Note
Because some C Series modules may have more stringent certification
standards than the NI cDAQ-9136, the combined system may be limited by
individual component restrictions. Refer to the NI cDAQ-9136 Specifications for
more details.
Hot Surface
component may result in bodily injury.
Safety Voltages
Connect only voltages that are below these limits.
V1 terminal to C terminal
V2 terminal to C terminal
Chassis ground to C terminal
Measurement Category I is for measurements performed on circuits not directly connected to
the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live
electrical supply system that powers equipment. This category is for measurements of voltages
from specially protected secondary circuits. Such voltage measurements include signal levels,
special equipment, limited-energy parts of equipment, circuits powered by regulated low-
voltage sources, and electronics.
-9136
Do not operate the NI cDAQ-9136 in a manner not specified in this user
This icon denotes that the component may be hot. Touching this
30 VDC maximum, Measurement Category I
30 VDC maximum, Measurement Category I
30 VDC maximum, Measurement Category I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NI cDAQ-9136 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments NI cDAQ-9136

  • Page 1 Safety Guidelines Caution Do not operate the NI cDAQ-9136 in a manner not specified in this user manual. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair.
  • Page 2: Safety Guidelines For Hazardous Locations

    Safety Guidelines for Hazardous Locations The NI cDAQ-9136 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
  • Page 3: Power Requirements

    The enclosure must have a door or cover accessible only by the use of a tool. Power Requirements Caution The protection provided by the NI cDAQ-9136 can be impaired if it is used in a manner not described in the user documentation. Note Some C Series modules have additional power requirements. For more information about C Series module power requirements, refer to the C Series module(s) documentation.
  • Page 4 The NI cDAQ-9136 filters and regulates the supplied power and provides power to all of the I/O modules. The NI cDAQ-9136 has a primary power input, V1, and a secondary power input, V2. The POWER LED on the front panel identifies the power input in use.
  • Page 5: Preparing The Environment

    The cDAQ controller uses V1 if the voltage across V1 and C is 9 V or greater. If the V1-to-C voltage drops below 9 V, the NI cDAQ-9136 switches to V2. If the V2-to-C voltage is less than 9 V, operation may be interrupted.
  • Page 6: Electromagnetic Compatibility Guidelines

    RS-232 port must be no longer than 30 m (100 ft). Caution The USB device port is intended for use in device configuration, application deployment, debug, and maintenance. 6 | ni.com | NI cDAQ-9136 Safety, Environmental, and Regulatory Information...
  • Page 7: Special Conditions For Marine Applications

    Caution Do not hot-swap USB devices while the NI cDAQ-9136 is in a hazardous location or connected to high voltages. If the NI cDAQ-9136 is not in a hazardous location, you can connect and disconnect USB devices without affecting operation.
  • Page 8: Where To Go Next

    CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2015 National Instruments. All rights reserved. 375227B-02 Nov15...

Table of Contents