Installation

Electrical connection

Before connecting the appliance, make
sure that the connection data on the
data plate (voltage and frequency)
matches the mains electricity supply.
This data must correspond in order to
avoid the risk of damage to the
appliance. If in any doubt, consult a
qualified electrician.
The necessary connection information
is given on the data plate inside your
appliance.
The fuse rating must be at least 10 A.
The socket should be easily accessible.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3 mm. These
include isolator switches, fuses and
relays.
Temporary or permanent operation with
a self-sufficient or non-mains
synchronous energy supply system
(e.g. isolated networks, back-up
systems) is possible. A requirement for
the operation is that the energy supply
system complies with all current local
and national requirements that apply to
stand-alone, solar and/or battery
systems.
The protective measures provided in
the domestic installation and in this
Miele product must also be assured in
their function and operation in isolated
operation or in non-mains synchronous
operation, or replaced with equivalent
measures in the installation.
84
The machine must not be used with so-
called energy-saving plugs. These
reduce the amount of energy supplied
to the machine, causing it to overheat.