  • Page 1 User Manual Envertech Corporation Ltd. Tel: +86 21 6858 0086 Web: www.envertec.com EVT800-R Email: info@envertec.com Add: No.138, Xinjunhuan road, Minhang District, Shanghai, China USM-R-2023-V01...
  • Page 2: Table Of Contents

    Content Important Safety Information ....... 1 Read it First ............... 1 Safety Instructions ............ 1 Envertech Microinverter System ......1 How it Works ............2 Monitoring Device EnverBridge ........ 2 Optimal Reliability............. 3 Simple Design ............3 Product Information ..........3 Overview ..............
  • Page 3: Important Safety Information

    Please be kindly note that the Envertech microinverter itself is a heat sink. WARNING indicates a hazardous situation which, if not Under normal operating conditions, its temperature is 20°C above ambient, but avoided, can result in death or serious injury or moderate injury.
  • Page 4: How It Works

    EnverBridge (Optional): Monitoring and protecting PV system. You can view the real-time data from a web browser or Envertech app. This integrated solar system maximizes energy harvest, increases system reliability. Simplifies design, installation and management. 2.1 How it Works EnverPortal: http://www.envertecportal.com The Envertech microinverter maximizes energy production from your photovoltaic (PV) array.
  • Page 5: Optimal Reliability

    The distributed nature of a microinverter system ensures that there is no single point failure in the PV system. Envertech Microinverters are designed to operate at full power at ambient temperatures as high as +65 ℃ (150 ℉ ). The microinverter casing is designed for outdoor installation and complies with the IP67 protection level.
  • Page 6: Preparation

    6 Units 4. Packing Checklist Cable) 4.1 Accessories Efficiency After you receive the Envertech microinverter, please check if there is any Peak Efficiency 96.8% damage on the carton, and then check the inside completeness for any visible MPPT Efficiency 99.9% external damage on the microinverter and accessories.
  • Page 7: Product Description

    If you have any further questions concerning accessories or installation, please Any unauthorized perforations or modifications are strictly forbidden. If any defect or damage check our website www.envertec.com or send an email to tech@envertec.com. (device/person) is occurred, Envertech shall not take any responsibility for it.
  • Page 8: Accessories

    Mark out the estimated center of each PV module on the rack to facilitate locating microinverters. Only qualified personnel may connect the Envertech microinverter to Mount all microinverters under modules to avoid rain and sun, with the the utility grid after receiving prior approval from the electrical utility trademark facing downward.
  • Page 9 Step 3. Ground the system Microinverters and modules must be connected to the grounding conductor in accordance with national standards. Fix the screws to the microinverter installation hole. Make sure that the grounding screw thread is pierced into the bracket to get the best grounding effect. Step 7.
  • Page 10 Model: EVT800 Temperature( ℃ ): -40 ℃ to +65 ℃ User Identification Number Envertech(Shanghai)Corporation LTD. www.envertec.com Step 8. Connect PV modules to microinverters a. Open EnverView app and click Wi-Fi. Select “EVT” to connect. Mount the PV modules on top of the microinverters; Connect each PV module with the DC input cables of the microinverter.
  • Page 11 characters. 3. Please ensure that the current network your phone connect to is 2.4GHz Wi- Fi, and the connection between your router and the Internet is in good condition. c. Connect the network whose name is as same as your EVT’s SN, and return to the app.
  • Page 12 3. Click "STA Setting" for the relevant configuration, and click "Scan" to scan 6. After the above operation, click "Restart". It will restart after 5 seconds. the Wi-Fi. 4. Select the current wireless network, and press "OK". Note: If more than one microinverter needs to be connected to Wi-Fi, configure one microinverter first.
  • Page 13 Option 1. Visit www.envertecportal.com. Click Sign Up. Fill in the account information to finish registration. Option 2. Use the app “EnverView” to register Option 2. Use EnverView app to bind MI (Local mode) Note: Please ensure that both EVT800 and your phone are in same router network.
  • Page 14 Components To use the local mode on EVB300, additional accessories should be prepared. • EVB300 (Firmware version EVB-300-E-N-003-014 or higher) • A USB flash drive with the sufficient storage space (format: FAT16/32 or exFAT) Operating steps Insert the USB flash drive into the USB socket on EVB300. Note: Insert the USB flash drive into the USB socket on EVB300 as shown on the following picture.
  • Page 15: Debugging And Operating

    Please notice the symbols. week. Click and select the time range to get the detailed data Only qualified personnel may connect the Envertech microinverter Precise Query to the utility grid after receiving prior approval from the electrical Click and select the time range to get the detailed data.
  • Page 16: Energize The System

    1. If red light flashes every 2 or 3 seconds, it indicates that the microinverter is waiting for sun or prepare to produce energy. The Envertech microinverter is powered on when there is sufficient DC voltage from the PV module. The LED light of each microinverter will blink green to 2.
  • Page 17: Disconnect Microinverters From Pv Modules

    Envertech microinverter. connection may need to be tightened or reseated. If the connection is worn out WARNING: Envertech microinverters are powered by DC power from the PV or damaged, it needs replacement. modules. Please disconnect and reconnect DC power to check the LED blinks 1 11.
  • Page 18: System Diagram

    IP67 O v erv oltage Category: Protec tiv e Class: O VC III (AC Main), O VC II ( PV) Class I Z hejiang Envertech Corporation Ltd. Z hejiang Envertech Corporation Ltd. Z hejiang Envertech Corporation Ltd. www.envertec.com www.envertec.com www.envertec.com...
  • Page 19: Recycling And Disposal

    9. Recycling and Disposal WARNING: Do not attempt to repair the Envertech microinverter. It contains no user-serviceable parts. If the microinverter fails, contact your direct supplier or Envertech customer service to obtain an RMA (return merchandise authorization) number and start the replacement process.