Download Print this page

Mitsubishi Electric MS-09DW-U1 Technical & Service Manual page 45

Ductless split-type air conditioners

Advertisement

r.-
1
OPERATING PROCEDURE
5.
Removing of the
rear
panel
(
1) Remove
3 screws on
the top.
(-2)
Rem
ove
2
screws on
the
service
panel
sides.
(3) Remove
10
screws
on
the rear side.
(4
)
Remove 2 screws
of
the conduit cover.
(5)
Diconnect
co
nnecting
w ires
from
the terminal block
of
In/O
ut
door unit.
(6) Remove the
rear
panel.
6. Removing of
electrical parts
( 1)
Remove the
service
panel.
Remove 2 set
screws.
Remove the service
panel
pulling
to your side.
(3)
Electrical
parts can be removed.
7.
Removing
of the outdoor fan
motor
( 1)
Remove
the
top panel, service
panel, side panel
and
front
panel
.
(2)
Remove the
propeller
set nut.
(3) Remove
the
propeller.
(4)
Disconnect
the
connecting
w ires
of
t he
outdor
fan
m
otor.
(5) Remove
the set screws of
the outdoor
fan motor.
(6) Remove
t he outdoor fan motor.
Photo
4
Set screws
(side)
Set screws
(for conduit
cover)
Photo 5
Transformer
PHOTOS
C1
,C2,C3,
Set screws
(top)
Set screws
(rear)
Run
capacitor
Outdoor
P.C.
board
Terminal
block
TB2 ,TB3,TB4
Terminal
block
TB1
Photo 6
Set screws
(for outdoor fan motor)
Set
nut
44