Mitsubishi Electric CITY MULTI CMB-WM108V-AA Installation Manual
Mitsubishi Electric CITY MULTI CMB-WM108V-AA Installation Manual

Mitsubishi Electric CITY MULTI CMB-WM108V-AA Installation Manual

Air-conditioners for building application
Hide thumbs Also See for CITY MULTI CMB-WM108V-AA:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
CMB-WM108V-AA, CMB-WM1016V-AA
CMB-WM108V-AB, CMB-WM1016V-AB
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemä en Gebrauch der Klimageräte das Installationshandbuch gr ndlich durchlesen.
MANUEL D INSTALLATION
Veuille lire le manuel d installation en entier avant d installer ce climatiseur pour éviter tout accident et vous assurer d une utilisation correcte.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u de e installatiehandleiding grondig doorle en voordat u de airconditioner installeert.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installa ione prima di installare il condi ionatore d aria.
ΕΓ ΕΙΡΙΔΙΟ ΟΔΗΓΙ Ν ΕΓΚΑΤΑΣΤΑΣΗΣ
Για ασ άλεια και σωστή χρήση, αρακαλε στε διαβάσετε ροσεχτικά αυτό το εγχειρ διο εγκατάστασης ριν αρχ σετε την εγκατάσταση της μονάδας
κλιματισμού.
MANUAL DE INSTALAÇ O
Para segurança e utili ação correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
INSTALLATIONSMANUAL
Læs venligst denne installationsmanual grundigt, f r De installerer airconditionanlægget, af hensyn til sikker og korrekt anvendelse.
INSTALLATIONSHANDBOK
Läs den här installationshandboken noga innan luftkonditioneringsenheten installeras, för säker och korrekt användning.
MONTAJ ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için l tfen klima ciha ını monte etmeden önce bu elkitabını dikkatle okuyunu .
РЪКОВОДСТВО ЗА МОНТАЖ
За безопасна и правилна употреба, моля, прочетете внимателно това ръководство преди монтажа на климатизатора.
PODRĘCZNIK INSTALACJI
W celu be piec nego i poprawnego kor ystania należy pr ed ainstalowaniem klimaty atora dokładnie apo nać si
instalacji.
INSTALLASJONSHÅNDBOK
For sikker og riktig bruk, skal du lese denne installasjonshåndboken n ye f r du installerer klimaanlegget.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по установке до
выполнения установки кондиционера.
PŘÍRUČKA K INSTALACI
V ájmu be pečného a správného pou ván si před instalac klimati ačn jednotky d kladn pročt te tuto př ručku k instalaci.
N VOD NA INŠTAL CIU
Pre be pečné a správne pou itie si pred inštalovan m klimati ačnej jednotky, pros m, starostlivo preč tajte tento návod na inštaláciu.
TELEPÍT SI K ZIKÖNYV
A bi tonságos és helyes has nálatho , kérj k, olvassa el alaposan e t a telep tési ké ikönyvet, miel tt telep tené a légkondicionáló egységet.
PRIROČNIK ZA NAMESTITEV
Za varno in pravilno uporabo pred namestitvijo klimatske naprave skrbno preberite priro čnik a namestitev.
MANUAL CU INSTRUCŢIUNI DE INSTALARE
Pentru o utili are corect
PRIRUČNIK ZA UGRADNJU
Radi sigurne i ispravne uporabe, temeljito pročitajte ovaj priručnik prije ugradnje klimati acijskog ure aja.
为了
正 地使
PDF created with pdfFactory Pro trial version
i sigur , v rug m s citi i cu aten ie acest manual înainte de a instala unitatea de aer condi ionat.
www.pdffactory.com
<ORIGINAL
niniejs ym podr c nikiem

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI CMB-WM108V-AA

  • Page 1 <ORIGINAL Air-Conditioners For Building Application INDOOR UNIT CMB-WM108V-AA, CMB-WM1016V-AA CMB-WM108V-AB, CMB-WM1016V-AB INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemä en Gebrauch der Klimageräte das Installationshandbuch gr ndlich durchlesen. MANUEL D INSTALLATION Veuille lire le manuel d installation en entier avant d installer ce climatiseur pour éviter tout accident et vous assurer d une utilisation correcte.
  • Page 2 Fig. 2.2.1 Fig. 2.3.1 <A Top view <B Front view (Unit: mm) Model name CMB-WM108V-AA 1520 A Inspection hole CMB-WM1016V-AA 1800 B Side of outdoor unit piping CMB-WM108V-AB 1520 C Control box CMB-WM1016V-AB 1520 D Side of indoor unit piping E Water inlet F Service space G Indoor unit side...
  • Page 3 Fig. 3.2.1 1 Hanging method A: Min. 30 mm A Hanging bolt 10 (field supply) B Washer (field supply) <Top view> Fig. 4.1.2 HBC CONTROLLER Unit model Model name High pressure side Low pressure side PURY-(E)P200 15.88 (Bra ing) 19.05 (Bra ing) PURY-(E)P250 19.05 (Bra ing) 22.2 (Bra ing)
  • Page 4 Fig. 4.3.1 A Locally procured insulating material for pipes B Bind here using band or tape. C Do not leave any opening. D Lap margin: more than 40 mm E Insulating material (field supply) F Unit side insulating material Fig. 4.4.1 Fig.
  • Page 5 Fig. 5.1.3 A HBC controller B Sub-HBC controller C To Sub-HBC controller (Hot water) D From Sub-HBC controller (Hot water) E To Sub-HBC controller (Cold water) F From Sub-HBC controller (Cold water) Fig. 5.2.1 A Locally procured insulating material for pipes B Bind here using band or tape.
  • Page 6: Table Of Contents

    Always use accessories specified by Mitsubishi Electric. - If a different refrigerant or air is mixed with the original refrigerant, the - Ask an authori ed technician to install the accessories. Improper installation by refrigerant cycle may malfunction and the unit may be damaged.
  • Page 7: Precautions For Devices That Use R410A And R32 Refrigerants

    - If the pressure switch, thermal switch, or other protection device is shorted or erroneously, or fail to operate. On the other hand, the air conditioner may affect operated forcibly, or parts other than those specified by Mitsubishi Electric are such equipment by creating noise that disturbs medical treatment or image used, fire or explosion may result.
  • Page 8: Selecting An Installation Site

    2. Selecting an installation site 2.1. About the product 2.3. Securing installation and service space This unit uses R410A-type or R32-type refrigerant. 1. For hanging from the ceiling (This is a reference view showing the least installation space.) Indoor units that are all WP or all W models are connectable to the HBC controller.
  • Page 9: Installing The Hbc Controller

    Warning: (When R32 refrigerant is used) NG (ISO 5149) Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The unit shall be stored in a room without continuously operating ignition At least two safety sources (for example: open flames, an operating gas appliance or measures are...
  • Page 10: Connecting Refrigerant Pipes And Drain Pipes

    4. Connecting refrigerant pipes and drain pipes 4.1. Connecting refrigerant pipes Note: Be sure to use non-oxidative bra ing. 1. Be sure to use non-oxidative bra ing where necessary. If you do not use non-oxi- *1. Connection of multiple indoor units with one connection (or joint pipe) dative bra ing, it may clog the pipes.
  • Page 11: Additional Refrigerant Charge

    4.4. Additional refrigerant charge (E)M200 to 500YNW (R32 refrigerant) (1) Units m and kg Notes: <Formula Charge refrigerant in a liquid state. When the piping length from the outdoor unit to the farthest HBC controller is - Charging refrigerant in the gaseous state will change the composition of the 10 m (32 ft) or shorter refrigerant and lead to a performance drop.
  • Page 12 (2) Units ft and o (E)P200 to 500YNW (R410A refrigerant) <Formula (1) Units m and kg When the piping length from the outdoor unit to the farthest HBC controller is <Formula 10 m (32 ft) or shorter When the piping length from the outdoor unit to the farthest HBC controller is 30.5 m (100 ft) or shorter Amount of High-pressure pipe...
  • Page 13: Drain Piping Work

    4.5. Drain piping work As shown in 3, install a collecting pipe about 10 cm below the drain ports and give it a downward pitch of more than 1/100. This collecting pipe should be of VP- 1. Drain piping work Ensure that the drain piping is downward (sloped gradient of more than 1/100) to Set the end of drain piping in a place without any risk of odor generation.
  • Page 14: Water Treatment And Quality Control

    Installation of pipes in a high-temperature high-humidity environment, such as 11. Please refer to the Fig. 5.2.3 when connecting the water supply. the top floor of a building, may require the use of insulation materials thicker than Fig. 5.2.3 (P.5) the ones specified in the chart above.
  • Page 15: Electrical Work

    6. Electrical work Consult all related regulations and power companies beforehand. The switch capacity of the main power to HBC/Sub-HBC controllers and the wire si e  are as follows: Warning: Switch (A) Molded case Earth leakage Wire si e Electrical work should be handled by qualified electrical engineers in circuit breaker breaker...
  • Page 16 PDF created with pdfFactory Pro trial version www.pdffactory.com...
  • Page 17 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is Low Voltage Directive 2014/35/EU based on the following Electromagnetic Compatibility Directive EU regulations: 2014/30/EU Machinery Directive 2006/42/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.