Download Print this page
Mitsubishi Electric CMB-WM-V-AA Data Book
Mitsubishi Electric CMB-WM-V-AA Data Book

Mitsubishi Electric CMB-WM-V-AA Data Book

Air conditioning systems

Advertisement

AIR CONDITIONING SYSTEMS
MODEL
CMB-WM-V-AA
CMB-WM-V-AB
EIo-1

Advertisement

loading

Summary of Contents for Mitsubishi Electric CMB-WM-V-AA

  • Page 1 AIR CONDITIONING SYSTEMS MODEL CMB-WM-V-AA CMB-WM-V-AB EIo-1...
  • Page 2: Table Of Contents

    HBC controller Indoor units CMB-WM-V-AA, CMB-WM-V-AB (for YNW/YLM-Series) I.HBC controller 1. SPECIFICATIONS ............................2 2. EXTERNAL DIMENSIONS ..........................6 3. CENTER OF GRAVITY ..........................10 4. ELECTRICAL WIRING DIAGRAMS ......................11 5. SOUND LEVELS ............................15 5-1. Sound levels ............................15 5-2.
  • Page 3: Specifications

    1. SPECIFICATIONS Indoor units I.HBC controller 1. SPECIFICATIONS Model name CMB-WM108V-AA Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz Power input Cooling 0.45/0.46/0.47 0.45/0.46/0.47 (220/230/240) Heating 0.45/0.46/0.47 0.45/0.46/0.47 Current input Cooling 2.89/2.83/2.79 2.89/2.83/2.79 (220/230/240) Heating 2.89/2.83/2.79 2.89/2.83/2.79 Sound pressure level (measured in anechoice room) dB <A>...
  • Page 4 1. SPECIFICATIONS Indoor units Model name CMB-WM1016V-AA Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz Power input Cooling 0.45/0.46/0.47 0.45/0.46/0.47 (220/230/240) Heating 0.45/0.46/0.47 0.45/0.46/0.47 Current input Cooling 2.89/2.83/2.79 2.89/2.83/2.79 (220/230/240) Heating 2.89/2.83/2.79 2.89/2.83/2.79 Sound pressure level (measured in anechoice room) dB <A>...
  • Page 5 1. SPECIFICATIONS Indoor units Model name CMB-WM108V-AB Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz Power input Cooling 0.01/0.01/0.01 0.01/0.01/0.01 (220/230/240) Heating 0.01/0.01/0.01 0.01/0.01/0.01 Current input Cooling 0.05/0.05/0.05 0.05/0.05/0.05 (220/230/240) Heating 0.05/0.05/0.05 0.05/0.05/0.05 Sound pressure level (measured in anechoice room) dB <A>...
  • Page 6 1. SPECIFICATIONS Indoor units Model name CMB-WM1016V-AB Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz Power input Cooling 0.01/0.01/0.01 0.01/0.01/0.01 (220/230/240) Heating 0.01/0.01/0.01 0.01/0.01/0.01 Current input Cooling 0.05/0.05/0.05 0.05/0.05/0.05 (220/230/240) Heating 0.05/0.05/0.05 0.05/0.05/0.05 Sound pressure level (measured in anechoice room) dB <A>...
  • Page 7: External Dimensions

    2. EXTERNAL DIMENSIONS Indoor units 2. EXTERNAL DIMENSIONS CMB-WM108V-AA Unit : mm EIo-1 MEES17K102...
  • Page 8 2. EXTERNAL DIMENSIONS Indoor units CMB-WM1016V-AA Unit : mm EIo-1 MEES17K102...
  • Page 9 2. EXTERNAL DIMENSIONS Indoor units CMB-WM108V-AB Unit : mm EIo-1 MEES17K102...
  • Page 10 2. EXTERNAL DIMENSIONS Indoor units CMB-WM1016V-AB Unit : mm EIo-1 MEES17K102...
  • Page 11: Center Of Gravity

    3. CENTER OF GRAVITY Indoor units 3. CENTER OF GRAVITY CMB-WM108, 1016V-AA CMB-WM108, 1016V-AB Indoor unit branching point Center of gravity CMB-WM108V-AA CMB-WM1016V-AA CMB-WM108V-AB CMB-WM1016V-AB A (mm) 1379 1659 1379 1379 x (mm) y (mm) z (mm) EIo-1 MEES17K102...
  • Page 12: Electrical Wiring Diagrams

    4. ELECTRICAL WIRING DIAGRAMS Indoor units 4. ELECTRICAL WIRING DIAGRAMS CMB-WM108V-AA EIo-1 MEES17K102...
  • Page 13 4. ELECTRICAL WIRING DIAGRAMS Indoor units CMB-WM1016V-AA EIo-1 MEES17K102...
  • Page 14 4. ELECTRICAL WIRING DIAGRAMS Indoor units CMB-WM108V-AB EIo-1 MEES17K102...
  • Page 15 4. ELECTRICAL WIRING DIAGRAMS Indoor units CMB-WM1016V-AB EIo-1 MEES17K102...
  • Page 16: Sound Levels

    5. SOUND LEVELS Indoor units 5-1. Sound levels 5. SOUND LEVELS (Measured point) CMB-WM108V-AA CMB-WM1016V-AA Measurement location Measured in anechoic room. 5-2. NC curves CMB-WM108V-AA,CMB-WM1016V-AA Power Source: 230V, 50Hz 70.0 65.0 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0...
  • Page 17: Electrical Characteristics

    6. ELECTRICAL CHARACTERISTICS Indoor units 6. ELECTRICAL CHARACTERISTICS Symbols: MCA: Max. Circuit Amps, MFA: Max. Fuse Amps, RLA: Rated Load Amps Power supply HBC controller RLA(A) Volts Range+-10% MCA(A) MFA(A) 2.89 CMB-WM108V-AA Max.: 264V 50/60 3.49 2.83 CMB-WM1016V-AA Min.: 198V 2.79 0.05 CMB-WM108V-AB...
  • Page 18 - Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, repair, or at the time of disposal of the unit. - It may also be in violation of applicable laws. - MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant.