Blade Settings - Fujitsu CT114 Instruction Manual

Large diameter optical fiber cleaver
Table of Contents

Advertisement

Cleave Menu

Blade Settings

The parameters of the cleaving blade can be set.
Parameter
Blade Settings
Blade Speed
Blade Forward Steps
Blade Reverse Steps
Blade Approach Steps
Target Cleave Count
Cleave Oscillation Limit
Cleave Blade Start
Position Auto Adjust
The blade motion during the cleave is shown below.
Fiber position
Cleave
Start
Position
Description
Sets the speed of cleaving blade during oscillation.
Sets the cleaving blade forward distance.
This parameter cannot be set smaller than "Blade Reverse
Steps."
Sets the cleaving blade reverse distance.
This parameter cannot be set larger than "Blade Forward
Steps".
Shows the value: Blade Forward Steps – Blade Reverse Steps
Sets the blade oscillation count until the fiber should be
cleaved.
Sets a limit on the number of times the blade may oscillate.
If set to "ON", the cleave count will be adjusted to the "Target
Cleave Count" with each oscillation.
If set to "OFF," the cleaver does not adjust the cleave count.
Blade
Blade
Forward
Reverse
Step
Step
Cleaving
CT114_Rev
Blade
Speed
2
Time
52