Configuration Information
step No.
Prompt and Response
xx is the current highest hardware device address that can
be
assigned.
Press
[RETURN)
if
xx
is
satisfactory.
Otherwise, enter a higher DRT number.
8
lOGICAL DEVICE #?
Enter the logical device number of the lANIC.
(Enter an
unused logical device number.)
9
DRT #?
Enter
the
DRT
number.
The
DRT
number
is
computed
as
follows:
For Series 3x and 4x systems, the DRT number is the channel
number times 8.
(The channel number is set witn switch SW2
as described in Section 6.)
For Series
6x
systems,
the
DRT
number
is
computed
as
follows:
(CHAN NO. x 8)
+
(IMB x 128)
=
DRT.
(The CHAN NO.
is set with SW2 as desc r i bed in Sec
J
tlon 6.)
10
UNIT #?
0
11
SOFTWARE CHANNEL #?
0
12
TYPE? 17
13
SUBTYPE?
9
38
DRIVER NAME?
IOlAND
Update 1 (July 1986)