3. Remove the BigBag and remove the dust outlets.
4. Remove the 4 bolts (A), the clamp strip (B) and the
sealing blade (C) of the rotating valve seal.
C
A
5. Remove the 2 bolts on the drive motor plate.
2121 - 002 - 04.07.2023
B
6. Turn the drive motor to until you can remove the next
set of sealing blades.
7. Do the same procedure until all sealing blades are
removed.
8. To install new sealing blades, do these steps for
each set of sealing blades:
a) Apply threadlocker on 4 new bolts.
b) Install a new sealing blade, the clamp strip and
the 4 bolts.
c) Tighten the 2 bolts in the center first, then tighten
the bolts at each end of the clamp strip.
9. Make sure that the sealing blade aligns with the
housing of the rotating valve and that there is a
minimum clearance.