Husqvarna DC 2-48 Operator's Manual page 11

Table of Contents

Advertisement

Available languages

Available languages

7. Do a check of the warning indicator of the motor
protection. If the indicator is still on, speak to your
Husqvarna service agent.
To start the product
To do before you operate the product
1. Do all steps in
on page 9 .
2. Make sure that the 2 airflow hatches are closed.
3. Make sure that the dust extraction hoses between
the product and the secondary product are attached
correctly.
4. Start the compressor.
5. Start the motor for the rotating valves.
2121 - 002 - 04.07.2023
6. Start the fans and wait until the fans are at full
speed.
Note:
The 2 fans do not start at the same time.
When the first fan is at full speed, the second fan
starts. The airflow hatches open automatically.
WARNING:
system when the product is in operation.
To stop the product
1. If you stop the product temporarily, stop only the
fans. The airflow hatches close automatically.
Note:
When the air compressor is on during a
short stop, the product cleans the primary filters.
WARNING:
intakes are closed during the product
cleaning cycle. If the air intakes are not
closed, dust goes into the air. The dust
particles are dangerous to your health.
2. If you stop the product for more than 1 hour, stop the
fans, then do the steps that follow:
Do not use the drive
Make sure that the air
11