Lenovo 7DCE Messages Manual

Hide thumbs Also See for 7DCE:

Advertisement

Quick Links

ThinkSystem ST250 V3
Messages and Codes Reference
Machine Types: 7DCE, 7DCF

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo 7DCE

  • Page 1 ThinkSystem ST250 V3 Messages and Codes Reference Machine Types: 7DCE, 7DCF...
  • Page 2 Before using this information and the product it supports, be sure to read and understand the safety information and the safety instructions, which are available at: https://pubs.lenovo.com/safety_documentation/ In addition, be sure that you are familiar with the terms and conditions of the Lenovo warranty for your server, which can be found at: http://datacentersupport.lenovo.com/warrantylookup First Edition (February 2024) ©...
  • Page 3: Table Of Contents

    Chapter 3. UEFI events ..145 Contacting Support ... . . 193 UEFI events organized by severity ..145 © Copyright Lenovo 2024...
  • Page 4 ThinkSystem ST250 V3 Messages and Codes Reference...
  • Page 5: Chapter 1. Messages

    Lenovo XClarity Provisioning Manager (although these events are not stored in the event log). Use this section to view the events that can be generated by Lenovo XClarity Controller, UEFI, or the Lenovo XClarity Provisioning Manager. For each event, a user action is available to help you understand what must be done to resolve the issue.
  • Page 6 – DA. Display - Graphics adapters, op panel, monitor/console (including front/back panel, control panel, LCD panel etc). – IO. I/O connectivity - PCI/USB hub, bridge, bus, risers, configuration settings, interconnect, keyboard, mouse, KVM. – MA. Memory - Includes DIMMs, memory card, configuration settings, memory controller, redundant modes (mirroring, spare, etc), RAID memory, NVRAM, EPROM.
  • Page 7 – SS. Systems Management - Service & Support. – TR. Time Reference - RTC, Master clock, drawer clocks, NTP. – UN. Unknown/any entity. – UP. LEPT Firmware Update. – UP. Systems Management - Updates. – WD. System management - Watchdog. •...
  • Page 8 ThinkSystem ST250 V3 Messages and Codes Reference...
  • Page 9: Chapter 2. Xclarity Controller Events

    Chapter 2. XClarity Controller events When a hardware event is detected by the Lenovo XClarity Controller on the server, the Lenovo XClarity Controller writes that event in the system-event log on the server. Notes: Event identifier (ID) is a unique identifier used to search for XCC events. The event message may have one or more arguments, which could be replaceable text of FRU name or sensor name to identify the failed component.
  • Page 10: Xcc Events That Automatically Notify Support

    If you have configured this function and this field is set to Yes, Lenovo Support will be notified automatically if the event is generated. While you wait for Lenovo Support to call, you can perform the recommended actions for the event.
  • Page 11: Xcc Events Organized By Severity

    Table 1. Events that automatically notify Support (continued) Message String Event ID FQXSPIO0011N An Uncorrectable Error has occurred on [SensorElementName]. FQXSPIO0015M Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. FQXSPMA0007L Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. FQXSPMA0008N Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
  • Page 12 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPBR4005I Management Controller [arg1]: Configuration saved to a file by user Informational [arg2]. FQXSPBR4006I Management Controller [arg1]: Configuration restoration from a file by Informational user [arg2] completed. FQXSPBR4009I Management Controller [arg1]: cloning configuration from neighbor Informational server [arg2] by group name [arg3].
  • Page 13 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPDM4003I TKLM servers set by user [arg1]: TKLMServer1=[arg2] Port=[arg3], Informational TKLMServer2=[arg4] Port=[arg5], TKLMServer3=[arg6] Port=[arg7], TKLMServer4=[arg8] Port=[arg9]. FQXSPDM4004I TKLM servers device group set by user [arg1]: Informational TKLMServerDeviceGroup=[arg2] . FQXSPDM4005I User [arg1] has generated a new encryption key pair and installed a Informational...
  • Page 14 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPEM4010I UEFI Reported: [arg1]. Informational FQXSPEM4011I XCC failed to log previous event [arg1]. Informational FQXSPEM4012I User [arg1] made system [arg2] Encapsulation lite Mode. Informational FQXSPEM4013I Battery error was detected by RAID controller. The battery unit needs Informational replacement.([arg1],[arg2],[arg3],[arg4],[arg5]) FQXSPEM4014I...
  • Page 15 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPEM4027I Drive error was detected by RAID controller. Please check the event Informational logs and if events are targeted to the same disk then replace the drive. If necessary, contact technical support for additional assistance. ([arg1],[arg2],[arg3],[arg4],[arg5]) FQXSPEM4028I The port [arg1] of PCIe device [arg2] at [arg3] has link [arg4].
  • Page 16 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPMA0001I Error Detected and Corrected for [PhysicalMemoryElementName] on Informational Subsystem [MemoryElementName]. FQXSPMA0022I Post Package Repair Success for [PhysicalMemoryElementName] on Informational Subsystem [MemoryElementName]. FQXSPMA0023I Post Package Repair Failure for [PhysicalMemoryElementName] on Informational Subsystem [MemoryElementName].
  • Page 17 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPNM4019I DDNS registration successful. The domain name is [arg1]. Informational FQXSPNM4020I IPv6 enabled by user [arg1] . Informational FQXSPNM4021I IPv6 disabled by user [arg1] . Informational FQXSPNM4022I IPv6 static IP configuration enabled by user [arg1]. Informational FQXSPNM4023I IPv6 DHCP enabled by user [arg1].
  • Page 18 User [arg1] has set the SMTP Server reverse-path to [arg2]. Informational FQXSPNM4052I DHCP specified hostname is set to [arg1] by user [arg2]. Informational FQXSPNM4053I DNS discovery of Lenovo XClarity Administrator has been [arg1] by Informational user [arg2]. FQXSPNM4054I The hostname from DHCP is [arg1] by user [arg2]. Informational FQXSPNM4055I The hostname from DHCP is invalid.
  • Page 19 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPP4003I Server [arg1] scheduled for every [arg2] at [arg3] by user [arg4]. Informational FQXSPPP4004I Server [arg1] [arg2] cleared by user [arg3]. Informational FQXSPPP4005I The power cap value changed from [arg1] watts to [arg2] watts by Informational user [arg3].
  • Page 20 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPP4034I The server was powered off for an unknown reason. Informational FQXSPPP4035I The server was powered off by chassis control command. Informational FQXSPPP4036I The server was powered off via push button. Informational FQXSPPP4037I The server was powered off when the watchdog expired.
  • Page 21 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPW2003I Failure no longer predicted on [PowerSupplyElementName]. Informational FQXSPPW2006I [PowerSupplyElementName] has returned to a Normal Input State. Informational FQXSPPW2007I [PowerSupplyElementName] Configuration is OK. Informational FQXSPPW2008I [PowerSupplyElementName] has been turned on. Informational FQXSPPW2018I [PowerSupplyElementName] out-of-range has returned to a Normal...
  • Page 22 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSD2003I Hot spare disabled for [ComputerSystemElementName]. Informational FQXSPSD2005I Critical Array [ComputerSystemElementName] has deasserted. Informational FQXSPSD2006I Array in system [ComputerSystemElementName] has been restored. Informational FQXSPSD2007I Rebuild completed for Array in system Informational [ComputerSystemElementName].
  • Page 23 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4013I Secure LDAP [arg1] by user [arg2]. Informational FQXSPSE4014I SSH [arg1] by user [arg2]. Informational FQXSPSE4015I Global Login General Settings set by user [arg1]: Informational AuthenticationMethod=[arg2], LockoutPeriod=[arg3], SessionTimeout=[arg4]. FQXSPSE4016I Global Login Account Security set by user [arg1]: PasswordRequired= Informational...
  • Page 24 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4037I Crypto mode modified from [arg1] to [arg2] by user [arg3]. Informational FQXSPSE4038I Minimum TLS level modified from [arg1] to [arg2] by user [arg3]. Informational FQXSPSE4039I Temporary user account [arg1] is created by inband tool. Informational FQXSPSE4040I Temporary user account [arg1] expires.
  • Page 25 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4063I The system guard configuration is updated: status=[arg1], hardware Informational inventory=[arg2] and action=[arg3] by user [arg4] from [arg5] at IP address [arg6]. FQXSPSE4064I SNMPv3 engine ID is changed from [arg1] to [arg2] by user [arg3] from Informational [arg4] at IP address [arg5].
  • Page 26 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPUN0048I The RAID controller in PCI slot [arg1] in optimal status. Informational FQXSPUN2009I Sensor [SensorElementName] has deasserted. Informational FQXSPUN2012I Sensor [SensorElementName] has deasserted. Informational FQXSPUN2018I Sensor [SensorElementName] has deasserted the transition from Informational normal to non-critical state.
  • Page 27 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPMA0011G Memory Logging Limit Reached for [PhysicalMemoryElementName] Warning on Subsystem [MemoryElementName]. FQXSPMA0024G Sensor [SensorElementName] has asserted. Warning Warning FQXSPNM4010I DHCP[[arg1]] failure, no IP address assigned. FQXSPNM4032I DHCPv6 failure, no IP address assigned. Warning FQXSPPP4009I The measured power value exceeded the power cap value.
  • Page 28 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPCA0017M Sensor [SensorElementName] has transitioned to critical from a less Error severe state. FQXSPCA0019N Sensor [SensorElementName] has transitioned to non-recoverable Error from a less severe state. FQXSPEA0002M Sensor [SensorElementName] has transitioned to critical from a less Error severe state.
  • Page 29 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPU0009N [ProcessorElementName] has a Configuration Mismatch. Error Error FQXSPPU0011N An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. Error FQXSPPW0002L [PowerSupplyElementName] has Failed. FQXSPPW0007L [PowerSupplyElementName] has a Configuration Mismatch. Error FQXSPPW0035M Numeric sensor [NumericSensorElementName] going low (lower...
  • Page 30: List Of Xclarity Controller Events

    3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPBR4002I: Management Controller [arg1] Reset was caused by restoring default values. This message is for the use case where a Management Controller has been reset due to a user restoring the configuration to default values.
  • Page 31 4. Disable the watchdog timer. 5. Check the integrity of the installed operating system. 6. If problem persists, collect Service Data log. 7. Contact Lenovo Support. • FQXSPBR4004I: Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2], OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5]. A user configures Server Timeouts...
  • Page 32 1. Retry the operation. 2. AC cycle the system. 3. If Problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPBR4008I: Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to start. This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to start.
  • Page 33 2. Retry the operation. 3. AC cycle the system. 4. If problem persists, collect Service Data log. 5. Contact Lenovo Support. • FQXSPBR4009I: Management Controller [arg1]: cloning configuration from neighbor server [arg2] by group name [arg3]. This message is for the use case where a user synchronizes a Management Controller configuration by Federation.
  • Page 34 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0258 User Action: Information only; no action is required. • FQXSPBR400DI: Neighbor group clone configuration was initiated by user [arg1]. This message is for the user initiated a Federation clone configuration.
  • Page 35 3. If the problem persists, visually inspect fans for physical damage, dust, or any other contamination. If yes, clean fans, and install fans. 4. If the problem still exist, then please contact Lenovo support. • FQXSPCA0007J: Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
  • Page 36 2. If the problem issue still exist, check XCC Web GUI to check the temperature value is still higher than system spec. 3. Please contact Lenovo support. • FQXSPCA0011N: Numeric sensor [NumericSensorElementName] going high (upper non- recoverable) has asserted. This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.
  • Page 37 3. Make sure that the room temperature is within operating specifications. 4. Check M.2 module is in the correct slot location by referring to user manual. 5. If the problem still exist, please contact Lenovo support. • FQXSPCA0019N: Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
  • Page 38 Automatically notify Support: No Alert Category: Warning - Temperature SNMP Trap ID: 12 CIM Prefix: PLAT CIM ID: 0491 User Action: Information only; no action is required • FQXSPCA2009I: Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted. This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted.
  • Page 39 This message is for the use case when an implementation has detected a Sensor transition to less severe from critical. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Temperature SNMP Trap ID: 0 CIM Prefix: PLAT CIM ID: 0523 User Action: Information only;...
  • Page 40 • FQXSPCN4002I: User [arg1] has terminated an active console session. A user has terminated an active console session Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0145 User Action: Information only;...
  • Page 41 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0142 User Action: Collect Service Data log and contact Lenovo Support. • FQXSPDM4003I: TKLM servers set by user [arg1]: TKLMServer1=[arg2] Port=[arg3], TKLMServer2= [arg4] Port=[arg5], TKLMServer3=[arg6] Port=[arg7], TKLMServer4=[arg8] Port=[arg9]. A user configured the TKLM servers...
  • Page 42 User generated a new encryption key pair and installed a self-signed certificate for the TKLM client Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0148 User Action: Information only; no action is required. •...
  • Page 43 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0162 User Action: Information only; no action is required. • FQXSPEA0001J: Sensor [SensorElementName] has transitioned from normal to non-critical state. This message is for the use case when an implementation has detected a Sensor transitioned to non- critical from normal.
  • Page 44 This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - Other SNMP Trap ID: 60 CIM Prefix: PLAT CIM ID: 0521 User Action: Use storcli or LSA to check if there is any warning or critical RAID event.
  • Page 45 This message is for the use case where a Management Controller Event Log on a system is 75% full. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Event Log Fullness SNMP Trap ID: 35 CIM Prefix: IMM CIM ID: 0037 User Action: Information only;...
  • Page 46 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0074 User Action: Information only; no action is required. • FQXSPEM4006I: Alert Configuration Global Event Notification set by user [arg1]: RetryLimit=[arg2], RetryInterval=[arg3], EntryInterval=[arg4]. A user changes the Global Event Notification settings. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 47 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0152 User Action: Information only; no action is required. • FQXSPEM4010I: UEFI Reported: [arg1]. UEFI audit event logged. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0161...
  • Page 48 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0202 User Action: Information only; no action is required. • FQXSPEM4014I: The RAID controller has problem with the battery. Please contact technical support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5]) The RAID controller has problem with the battery Severity: Info Serviceable: No Automatically notify Support: Yes...
  • Page 49 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0206 User Action: Information only; no action is required. • FQXSPEM4018I: Enclosure/Chassis issue detected with one or more units. Please check the enclosure/chassis units to repair the problem.([arg1],[arg2],[arg3],[arg4],[arg5]) Enclosure/Chassis issue detected with one or more units Severity: Info...
  • Page 50 Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0210 User Action: Information only; no action is required. • FQXSPEM4023I: One or more virtual drive are in abnormal status that may cause unavailable virtual drive.
  • Page 51 • FQXSPEM4026I: Drive error was detected by RAID controller. Please contact technical support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5]) Drive error was detected by RAID controller Severity: Info Serviceable: No Automatically notify Support: Yes Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0214 User Action: Information only;...
  • Page 52 • FQXSPEM4030I: A scheduled operation on the RAID controller has encountered an issue. Refer to RAID Logs under Server Management, Local Storage, for details.([arg1],[arg2],[arg3],[arg4],[arg5]) The RAID controller has scheduled operation issue Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0223 User Action:...
  • Page 53 Bare Metal Connection process has been started Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0143 User Action: Information only; no action is required. • FQXSPFC4001I: The bare metal update application reports a status of [arg1]. Bare Metal Update Application Status Severity: Info Serviceable: No...
  • Page 54 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
  • Page 55 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
  • Page 56 If the NMI button has not been pressed, complete the following steps: 1. Reboot the system. 2. If error still exist, then collect serivce log and contact Lenovo support. • FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName]. This message is for the use case when an implementation has detected a Bus Timeout.
  • Page 57 SNMP Trap ID: 50 CIM Prefix: PLAT CIM ID: 0240 User Action: Check http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error. 1. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and firmware.
  • Page 58 3. If there are no entries related to the error in the event log, contact Lenovo support • FQXSPIO0013N: A Fatal Bus Error has occurred on bus [SensorElementName]. This message is for the use case when an implementation has detected a Bus Fatal Error.
  • Page 59 3. If there are no entries related to the error in the event log, contact Lenovo support • FQXSPIO2000J: The connector [PhysicalConnectorElementName] has been disconnected. This message is for the use case when an implementation has detected a Connector was Disconnected.
  • Page 60 User Action: Information only; no action is required • FQXSPIO2006I: System [ComputerSystemElementName] has recovered from an NMI. This message is for the use case when an implementation has detected a Software NMI has been Recovered from. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Other SNMP Trap ID: 50...
  • Page 61 Information only; no action is required. • FQXSPIO4001I: GPU Board Status was changed by [arg1] of [arg1]. This message is for the use case where GPU Board Status was changed. Severity: Warning Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0276 User Action:...
  • Page 62 3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSPMA0007L: Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
  • Page 63 3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory channel. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error. 5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or problem persists, collect Service Data log.
  • Page 64 3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory channel. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error. 5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or problem persists, collect Service Data log.
  • Page 65 3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSPMA0025I: Sensor [SensorElementName] has asserted. This message is for the use case when an implementation has detected a Sensor has asserted.
  • Page 66 Information only; no action is required • FQXSPMA2010I: [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. This message is for the use case when an implementation has detected Memory is no longer Throttled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0143...
  • Page 67 Information only; no action is required. • FQXSPNM4001I: Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3]. This message is for the use case where a user modifies the Ethernet Port data rate. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0003...
  • Page 68 • FQXSPNM4005I: Ethernet interface [arg1] by user [arg2]. This message is for the use case where a user enables or disabled the ethernet interface. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0007 User Action: Information only;...
  • Page 69 2. Make sure that there is a DHCP server on the network that can assign an IP address to the XCC/ BMC. 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPNM4011I: ENET[[arg1]] DHCP-HSTN=[arg2], DN=[arg3], IP@=[arg4], SN=[arg5], GW@= [arg6], DNS1@=[arg7] .
  • Page 70 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0023 User Action: Information only; no action is required. • FQXSPNM4013I: LAN: Ethernet[[arg1]] interface is no longer active. This message is for the use case where a Management Controller ethernet interface is no longer active. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 71 CIM Prefix: IMM CIM ID: 0043 User Action: Information only; no action is required. • FQXSPNM4017I: Domain Source changed to [arg1] by user [arg2]. Domain source changed by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0044 User Action:...
  • Page 72 Information only; no action is required. • FQXSPNM4021I: IPv6 disabled by user [arg1] . IPv6 protocol is disabled by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0048 User Action: Information only;...
  • Page 73 IPv6 static assignment method is disabled by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0052 User Action: Information only; no action is required. • FQXSPNM4026I: IPv6 DHCP disabled by user [arg1]. IPv6 DHCP assignment method is disabled by user Severity: Info Serviceable: No...
  • Page 74 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0056 User Action: Information only; no action is required. • FQXSPNM4030I: ENET[[arg1]] DHCPv6-HSTN=[arg2], DN=[arg3], IP@=[arg4], Pref=[arg5], DNS1@= [arg5]. IPv6 DHCP-assigned address is active Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none...
  • Page 75 4. Contact Lenovo Support. • FQXSPNM4033I: Telnet port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the telnet port number Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0061 User Action: Information only;...
  • Page 76 A user has modified the CIM HTTP port number Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0065 User Action: Information only; no action is required. • FQXSPNM4038I: CIM/XML HTTPS port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the CIM HTTPS port number Severity: Info Serviceable: No...
  • Page 77 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0069 User Action: Information only; no action is required. • FQXSPNM4042I: Remote Presence port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the Remote Presence port number Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 78 Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0088 User Action: Information only; no action is required. • FQXSPNM4046I: LAN over USB [arg1] by user [arg2]. A user configured USB-LAN Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0089...
  • Page 79 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0216 User Action: Information only; no action is required. • FQXSPNM4053I: DNS discovery of Lenovo XClarity Administrator has been [arg1] by user [arg2]. DNS discovery of Lenovo XClarity Administrator Severity: Info Serviceable: No...
  • Page 80 User Action: Information only; no action is required. • FQXSPNM4054I: The hostname from DHCP is [arg1] by user [arg2]. This message is for getting hostname from DHCP. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - IMM Network event SNMP Trap ID: 37 CIM Prefix: IMM CIM ID: 0244 User Action:...
  • Page 81 Information only; no action is required. • FQXSPNM4058I: IP address of network interface [arg1] is modified from [arg2] to [arg3] by user [arg4]. This message is for the use case where user modifies the IP address of a Management Controller. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 82 4. Disable the watchdog. 5. Check the integrity of the installed operating system. 6. If problem persists, collect Service Data log. 7. Contact Lenovo Support. • FQXSPOS4003I: Platform Watchdog Timer expired for [arg1]. An implementation has detected an OS Loader Watchdog Timer Expired...
  • Page 83 3. Reinstall the RNDIS or cdc_ether device driver for the operating system. 4. Disable the watchdog. 5. If problem persists, collect Service Data log. 6. Contact Lenovo Support.Check the integrity of the installed operating system. • FQXSPOS4004I: Operating System status has changed to [arg1]. Operating System status change...
  • Page 84 Complete the following steps until the problem is solved: 1. Check if the OS watchdog is enabled 2. Check if the crash video recording is enabled 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. ThinkSystem ST250 V3 Messages and Codes Reference...
  • Page 85 • FQXSPOS4011I: OS failure screen capture with hardware error is [arg1] by user [arg2] from [arg3] at IP address [arg4]. OS failure screen capture with hardware error is enabled or disabled by user. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0280...
  • Page 86 A user configured a recurring Server Power Action Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0083 User Action: Information only; no action is required. • FQXSPPP4004I: Server [arg1] [arg2] cleared by user [arg3]. A user cleared a Server Power Action.
  • Page 87 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0115 User Action: Information only; no action is required. • FQXSPPP4008I: The soft minimum power cap value changed from [arg1] watts to [arg2] watts. Soft Minimum Power Cap value changed Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 88 CIM Prefix: IMM CIM ID: 0119 User Action: Information only; no action is required. • FQXSPPP4012I: Power capping was deactivated by user [arg1]. Power capping deactivated by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0120 User Action: Information only;...
  • Page 89 Information only; no action is required. • FQXSPPP4016I: Dynamic Power Savings mode has been turned off by user [arg1]. Dynamic Power Savings mode turned off by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0124 User Action: Information only;...
  • Page 90 Power exceeded cap recovered Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - Power SNMP Trap ID: 164 CIM Prefix: IMM CIM ID: 0130 User Action: Information only; no action is required. • FQXSPPP4021I: The new minimum power cap value has returned below the power cap value. Minimum Power Cap exceeds Power Cap recovered Severity: Info Serviceable: No...
  • Page 91 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0168 User Action: Information only; no action is required. • FQXSPPP4025I: The server was powered-up via power push button. Server was power-up via power push button Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 92 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0172 User Action: Information only; no action is required. • FQXSPPP4029I: The server was automatically powered on because the power restore policy is set to restore previous power state.. Server was automatically powered on because the power restore policy is set to restore previous power state.
  • Page 93 CIM Prefix: IMM CIM ID: 0176 User Action: Information only; no action is required. • FQXSPPP4033I: The server was powered up via Real Time Clock (scheduled power on). Server was powered up via Real Time Clock (scheduled power on) Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other...
  • Page 94 Information only; no action is required. • FQXSPPP4037I: The server was powered off when the watchdog expired. Server was powered off when the watchdog expired. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0181 User Action: Information only;...
  • Page 95 • FQXSPPP4041I: The server was powered off via Real Time Clock (scheduled power off). Server was powered up via Real Time Clock (scheduled power off) Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0185 User Action: Information only;...
  • Page 96 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0189 User Action: Information only; no action is required. • FQXSPPP4047I: Management Controller [arg1] reset was initiated by user [arg2]. This message is for the use case where a Management Controller reset is initiated by a user.
  • Page 97 4. Make sure that the microprocessor 1 heat sink is installed correctly and the thermal interface is correctly applied. 5. Once you finish the action above and can't solve issue, please contact Lenovo support. • FQXSPPU0002G: The Processor [ProcessorElementName] is operating in a Degraded State.
  • Page 98 User Action: Complete the following steps: 1. If the system board or firmware was just updated, check the Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 2. If problem persists, collect Service Data log.
  • Page 99 CIM Prefix: PLAT CIM ID: 0062 User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support.
  • Page 100 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPPU2000I: [ProcessorElementName] in slot [SlotElementName] has been removed. This message is for the use case when an implementation has detected a Processor has been Removed. Severity: Info...
  • Page 101 User Action: Information only; no action is required • FQXSPPW0002L: [PowerSupplyElementName] has Failed. This message is for the use case when an implementation has detected a Power Supply has failed. Severity: Error Serviceable: Yes Automatically notify Support: Yes Alert Category: Critical - Power SNMP Trap ID: 4 CIM Prefix: PLAT CIM ID: 0086 User Action:...
  • Page 102 CIM Prefix: PLAT CIM ID: 0100 User Action: Make sure power cables are connected correctly. • FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch. This message is for the use case when an implementation has detected a Power Supply with a Configuration Error. Severity: Error Serviceable: Yes Automatically notify Support: No...
  • Page 103 Serviceable: Yes Automatically notify Support: No Alert Category: Warning - Voltage SNMP Trap ID: 13 CIM Prefix: PLAT CIM ID: 0476 User Action: CMOS battery is recommended to replace with new one. • FQXSPPW0035M: Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
  • Page 104 2. Check the event log in XClarity Controller (XCC) Web GUI for the detailed information to reseat/ reinstall/upgrade the power supply units. 3. If the problem still exists, please contact Lenovo support. • FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe state.
  • Page 105 5. Contact Lenovo Support. • FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted. This message is for the use case when Redundancy Degraded has asserted. Severity: Warning Serviceable: Yes Automatically notify Support: No Alert Category: Warning - Redundant Power Supply SNMP Trap ID: 10...
  • Page 106 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: PLAT CIM ID: 0085 User Action: Information only; no action is required • FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status. This message is for the use case when an implementation has detected a Power Supply return to normal operational status.
  • Page 107 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Power SNMP Trap ID: 4 CIM Prefix: PLAT CIM ID: 0105 User Action: Information only; no action is required • FQXSPPW2008I: [PowerSupplyElementName] has been turned on. This message is for the use case when an implementation has detected a Power Unit that has been Enabled.
  • Page 108 This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Voltage SNMP Trap ID: 1 CIM Prefix: PLAT CIM ID: 0481 User Action: Information only;...
  • Page 109 Information only; no action is required • FQXSPPW2063I: Sensor [SensorElementName] has transitioned to a less severe state from critical. This message is for the use case when an implementation has detected a Sensor transition to less severe from critical. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Voltage...
  • Page 110 User Action: Information only; no action is required. • FQXSPPW4001I: PCIe Power Brake for [arg1] has been [arg2]. This message is for the use case where PCIe Power Brake. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0243 User Action:...
  • Page 111 Complete the following steps: 1. Make sure that the reported device is compatible by checking https://static.lenovo.com/us/en/ serverproven/index.shtml. 2. Collect the service data log from the management controller interface and contact Lenovo Support. • FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].
  • Page 112 This message is for the use case when an implementation has detected a Hot Spare has been Enabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0170 User Action: Information only;...
  • Page 113 • FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName]. This message is for the use case when an implementation has detected that an Array Rebuild is in Progress. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0178 User Action:...
  • Page 114 1. Replace any hard disk drive that is indicated by a lit status LED. 2. Re-create the array. 3. Restore the data from a backup. • FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. This message is for the use case when an implementation has detected a Drive has been Removed. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 115 Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0171 User Action: Information only; no action is required • FQXSPSD2005I: Critical Array [ComputerSystemElementName] has deasserted. This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.
  • Page 116 Serviceable: No Automatically notify Support: No Alert Category: Critical - Hard Disk drive SNMP Trap ID: 5 CIM Prefix: PLAT CIM ID: 0167 User Action: Information only; no action is required • FQXSPSD2010I: Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been removed. This message is for the use case when an implementation has detected a Drive has been Removed.
  • Page 117 • FQXSPSD2013I: Array critical deasserted on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]). This message is for the use case when an implementation has detected that an Critiacal Array has deasserted. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Hard Disk drive SNMP Trap ID: 5 CIM Prefix: PLAT CIM ID: 0175 User Action:...
  • Page 118 1. Make sure that the certificate that you are importing is correct and properly generated. 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support. • FQXSPSE4001I: Remote Login Successful. Login ID: [arg1] using [arg2] from [arg3] at IP address [arg4].
  • Page 119 Automatically notify Support: No Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0016 User Action: Complete the following steps until the problem is solved: 1. Make sure that the correct login ID and password are being used. 2.
  • Page 120 1. Make sure that the certificate that you are importing is correct and properly generated / certificate CSR is correct 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support. • FQXSPSE4007I: Security: Userid: [arg1] using [arg2] had [arg3] login failures from an SSH client at IP address [arg4].
  • Page 121 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0076 User Action: Information only; no action is required. • FQXSPSE4010I: LDAP set by user [arg1]: RootDN=[arg2], UIDSearchAttribute=[arg3], BindingMethod=[arg4], EnhancedRBS=[arg5], TargetName=[arg6], GroupFilter=[arg7], GroupAttribute=[arg8], LoginAttribute=[arg9].
  • Page 122 Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0093 User Action: Information only; no action is required. • FQXSPSE4014I: SSH [arg1] by user [arg2]. A user enables or disables SSH services Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 123 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0100 User Action: Information only; no action is required. • FQXSPSE4018I: User [arg1] removed. A user account was deleted Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none...
  • Page 124 Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0104 User Action: Information only; no action is required. • FQXSPSE4022I: User [arg1] for SNMPv3 set: AuthenticationProtocol=[arg2], PrivacyProtocol= [arg3], AccessType=[arg4], HostforTraps=[arg5] by user [arg6] from [arg7] at IP address [arg8]. User account SNMPv3 settings changed Severity: Info Serviceable: No...
  • Page 125 Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0108 User Action: Information only; no action is required. • FQXSPSE4026I: Security: Userid: [arg1] had [arg2] login failures from a CIM client at IP address [arg3].
  • Page 126 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0154 User Action: Information only; no action is required. • FQXSPSE4030I: Security: Userid: [arg1] had [arg2] login failures from IPMI serial client. This message is for the use case where a user has failed to log in to a Management Controller from IPMI serial client Severity: Info...
  • Page 127 Automatically notify Support: No Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0158 User Action: Information only; no action is required. • FQXSPSE4034I: User [arg1] has removed a certificate. User removed certificate Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other...
  • Page 128 CIM Prefix: IMM CIM ID: 0218 User Action: Information only; no action is required. • FQXSPSE4038I: Minimum TLS level modified from [arg1] to [arg2] by user [arg3]. Minimum TLS level modified Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0219 User Action:...
  • Page 129 User Action: Information only; no action is required. • FQXSPSE4042I: The third-party password function [arg1] by user [arg2] from [arg3] at IP address [arg4]. This message is for the use case where a user successfully switch the third-party password function. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 130 User Action: Information only; no action is required. • FQXSPSE4046I: The third-party password of the user [arg1] has been retrieved by user [arg2] from [arg3] at IP address [arg4]. This message is for the use case where a user successfully retrieving the third-party password. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 131 Information only; no action is required. • FQXSPSE4050I: [arg1] sent IPMI command from [arg2], raw data: [arg3][arg4][arg5]. This message is for the use case where IPMI command to be sent. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0251 User Action:...
  • Page 132 Information only; no action is required. • FQXSPSE4054I: IPMI SEL wrapping mode is [arg1] by user [arg2] at IP address [arg3]. IPMI SEL wrapping mode is changed. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0264 User Action:...
  • Page 133 A user account was deleted by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0268 User Action: Information only; no action is required. • FQXSPSE4059I: User [arg1] password modified by user [arg2] from [arg3] at IP address [arg4]. A user account was changed by user Severity: Info Serviceable: No...
  • Page 134 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0278 User Action: Information only; no action is required. • FQXSPSE4063I: The system guard configuration is updated: status=[arg1], hardware inventory= [arg2] and action=[arg3] by user [arg4] from [arg5] at IP address [arg6].
  • Page 135 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0284 User Action: Information only; no action is required. • FQXSPSE4067I: User [arg1] accessible interfaces is set to [arg2][arg3][arg4][arg5][arg6] by user [arg7] from [arg8] at IP address [arg9].
  • Page 136 • FQXSPSS4000I: Management Controller Test Alert Generated by [arg1]. This message is for the use case where a user has generated a Test Alert. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0040 User Action: Information only;...
  • Page 137 Test Call Home generated by user. Severity: Info Serviceable: No Automatically notify Support: Yes Alert Category: none SNMP Trap ID: CIM Prefix: IMM CIM ID: 0134 User Action: Information only; no action is required. • FQXSPSS4005I: Manual Call Home by user [arg1]: [arg2]. Manual Call Home by user.
  • Page 138 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0225 User Action: Information only; no action is required. • FQXSPSS4009I: System enters LXPM maintenance mode. The system enters maintenance mode Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other...
  • Page 139 SNMP Trap ID: CIM Prefix: IMM CIM ID: 0033 User Action: Complete the following steps until the problem is solved: 1. Make sure that the certificate that you are importing is correct. 2. Try to import the certificate again. • FQXSPTR4001I: Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST Auto-adjust= [arg4], Timezone=[arg5].
  • Page 140 Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0508 User Action: Reboot the system. If the problem still exist, press F1 or use LXPM to do XCC FW update. •...
  • Page 141 CIM Prefix: PLAT CIM ID: 0530 User Action: Complete the following steps: 1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this error. 2. Reboot the system. 3. If the error continues, replace the system-board assembly (see hardware maintenance manual).
  • Page 142 CIM Prefix: PLAT CIM ID: 0518 User Action: Information only; no action is required • FQXSPUN2009I: Sensor [SensorElementName] has deasserted. This message is for the use case when an implementation has detected a Sensor has deasserted. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID:...
  • Page 143 CIM Prefix: PLAT CIM ID: 0523 User Action: Information only; no action is required • FQXSPUN2023I: Sensor [SensorElementName] has deasserted the transition to non-recoverable. This message is for the use case when an implementation has detected that the Sensor transition to non- recoverable has deasserted.
  • Page 144 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPUP4001I: Flash of [arg1] from [arg2] succeeded for user [arg3] . This message is for the use case where a user has successfully flashed the firmware component (MC Main Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure Power Backplane, Integrated System Management).
  • Page 145 4. If problem persists, collect Service Data log. 5. Contact Lenovo Support. • FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt to flash the XCC firmware to the same level on all nodes/servers.
  • Page 146 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPUP4005I: FPGA firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt to flash the FPGA firmware to the same level on all nodes/servers.
  • Page 147 • FQXSPWD0001I: Reboot of system [ComputerSystemElementName] initiated by watchdog [WatchdogElementName]. This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0370 User Action:...
  • Page 148 User Action: Information only; no action is required ThinkSystem ST250 V3 Messages and Codes Reference...
  • Page 149: Chapter 3. Uefi Events

    UEFI error messages can be generated when the server starts up (POST) or while the server is running. UEFI error messages are logged in the Lenovo XClarity Controller event log in the server. For each event code, the following fields are displayed: Event identifier An identifier that uniquely identifies an event.
  • Page 150 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFPU0021I The TPM physical presence state has been cleared. Informational FQXSFPU0023I Secure Boot Image Verification Failure has been cleared as no failure Informational in this round boot. FQXSFPU0025I The default system settings have been restored.
  • Page 151 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFPU0022G The TPM configuration is not locked. Warning FQXSFPU0023G Secure Boot Image Verification Failure Warning. Warning FQXSFPU4033F TPM Firmware recovery is in progress. Please DO NOT power off or Warning reset system.
  • Page 152: List Of Uefi Events

    2. Search for the driver menu from System Settings and change settings appropriately. 3. Save settings and restart the system. 4. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFDD0002M: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
  • Page 153 • FQXSFDD0007G: Security Key Lifecycle Manager (SKLM) IPMI Error. Severity: Warning User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable service bulletin or UEFI firmware update that applies to this error. 2. A/C cycle the system. Chapter 3...
  • Page 154 User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable device driver, firmware update, version of service information for this product or other information that applies to this error. Load new device driver and any required firmware updates.
  • Page 155 User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable device driver, firmware update, version of service information for this product or other information that applies to this error. Load new device driver and any required firmware updates.
  • Page 156 User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error. 2. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting detected change in DIMM population that could be related to this problem.)
  • Page 157 3. Update UEFI firmware to the latest version. 4. If the problem persists, collect Service Data logs and contact Lenovo Support. Note: The solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.
  • Page 158 5. After you install qualified memory and power up the server, check to ensure this informational event is not logged again. 6. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]...
  • Page 159 Power cycle the system by removing power for a few seconds. b. Clear CMOS settings by removing battery for a few seconds. 5. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFMA0011I: Memory population change detected. [arg1]...
  • Page 160 Complete the following steps: 1. Reseat the affected DIMM. 2. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error. 3. If the problem persists, collect Service Data logs and contact Lenovo Support.
  • Page 161 [arg1] Socket number, 1-based. User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable service bulletin or UEFI firmware update that applies to this error. 2. Power off the system and remove A/C power. 3. Restore A/C power and power on the system.
  • Page 162 Severity: Error User Action: Complete the following steps: 1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this error. 2. Reflash UEFI image. 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem.
  • Page 163 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem. 4. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
  • Page 164 2. If the error recurs TPM related features will not work. 3. If the problem persists, collect Service Data logs and contact Lenovo Support. Note: The solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.
  • Page 165 ThinkSystem SR850P Types 7D2F, 7D2G, 7D2H > Hardware replacement procedures > processor board replacement>Enable TPM/TCM>Set the TPM version. 4. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFPU4046I: TPM Firmware will be updated from TPM1.2 to TPM2.0.
  • Page 166 Severity: Warning User Action: Complete the following steps: 1. Reboot the system. 2. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFPU4053G: System TPM_TCM_POLICY does not match the planar. Severity: Warning User Action: Complete the following steps: 1.
  • Page 167 Severity: Info User Action: Information only; no action is required. • FQXSFPU4061I: Restored default locking behavior of AHCI-attached SATA drives. Severity: Info User Action: Information only; no action is required. • FQXSFPU4080I: Host Power-On password has been changed. Severity: Info User Action: Information only;...
  • Page 168 3. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this error. 4. If the problem persists, collect Service Data logs and contact Lenovo Support. Note: The solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.
  • Page 169 Complete the following steps: 1. Review XCC logs for communication errors and resolve. 2. AC cycle the system. 3. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFSR0001M: [arg1] GPT corruption detected, DiskGUID: [arg2] Severity: Warning Parameters: [arg1] GPT corruption location.
  • Page 170 2. Connect at least one bootable device to the system. 3. Connect AC power to the system. 4. Power on system and retry. 5. If the problem persists, collect Service Data logs and contact Lenovo Support. • FQXSFTR0001L: An invalid date and time have been detected. Severity: Warning...
  • Page 171: Chapter 4. Xclarity Provisioning Manager Events

    Chapter 4. XClarity Provisioning Manager events The following events can be generated by the Lenovo XClarity Provisioning Manager. For each event code, the following fields are displayed: Event identifier An identifier that uniquely identifies an event. Event description The logged message string that appears for an event.
  • Page 172 Table 4. Events organized by severity (continued) Message String Severity Event ID FQXPMEM0004I Launching diagnostic program Informational FQXPMEM0005I boot diagnostic program success Informational FQXPMER0002I Clearing RAID configuration and internal storage Informational FQXPMER0003I RAID configuration cleared successfully Informational FQXPMER0004I Internal storage drives erased successfully Informational FQXPMER0005I All system logs cleared successfully...
  • Page 173 Table 4. Events organized by severity (continued) Message String Severity Event ID FQXPMOS0002K Failed to read Deployment Manager Signature from USB. Warning FQXPMOS0003K Failed to copy Windows boot files to target Warning FQXPMOS0004K BMC Communication Failed: EMMC2USB Mount Failure. Warning Warning FQXPMOS0005K BMC communication failed: DRIVER Mount Failure.
  • Page 174: List Of Xclarity Provisioning Manager Events

    FQXPMUP0208M Failed to execute reboot BMC command List of XClarity Provisioning Manager events This section lists all messages that can be sent from the Lenovo XClarity Provisioning Manager. • FQXPMCL0001K: Bootx64.efi is not found. Failed to Boot OS. Severity: Warning User Action: 1.
  • Page 175 3. Reboot system and retry OS booting. 4. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 5.
  • Page 176 • FQXPMCL0006K: Failed to export raid config. Severity: Warning User Action: 1. Check the following Lenovo support site for information on supported RAID adapters. http://www. lenovo.com/us/en/serverproven/index.shtml 2. Ensure RAID adapter, LXPM, and UEFI firmware are at the latest levels. 3. Ensure the state of the RAID adapter and disk drives are normal.
  • Page 177 6. Reboot the machine and retry the import of the RAID configuration. 7. If the problem persists, contact technical support. • FQXPMCL0008I: Export uefi settings successfully. Severity: Info User Action: Information only; no action is required. • FQXPMCL0008K: Failed to export uefi settings. Severity: Warning User Action: 1.
  • Page 178 3. Retry the export of BMC setting. 4. If the problem persists, contact technical support. • FQXPMCL0011I: Import bmc settings successfully. Severity: Info User Action: Information only; no action is required. • FQXPMCL0011K: Failed import bmc settings. Severity: Warning User Action: 1.
  • Page 179 Information only; no action is required. • FQXPMEM0005I: boot diagnostic program success Severity: Info User Action: Information only; no action is required. • FQXPMEM0006M: Unable to locate diagnostic firmware image Severity: Error User Action: 1. Restart BMC via supported method and reboot the system. 2.
  • Page 180 Severity: Error User Action: 1. Restart the system and retry the operation again. 2. If the problem persists, contact technical support. • FQXPMER0003I: RAID configuration cleared successfully Severity: Info User Action: Information only; no action is required. • FQXPMER0003M: Failed to erase internal storage drives Severity: Error User Action: 1.
  • Page 181 3. If the problem persists, contact technical support. • FQXPMER0006I: UEFI factory default settings loaded successfully Severity: Info User Action: Information only; no action is required. • FQXPMER0006M: Failed to load XCC factory default settings Severity: Error User Action: 1. Restart BMC via supported method and reboot the system. 2.
  • Page 182 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 5. If the problem persists, contact technical support. • FQXPMOS0002K: Failed to read Deployment Manager Signature from USB. Severity: Warning User Action: 1.
  • Page 183 User Action: 1. Ensure proper operation of the virtual USB connection. 2. Restart BMC via supported method and reboot the system. 3. Reflash BMC firmware. 4. Retry OS deployment. 5. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC.
  • Page 184 • FQXPMOS0009K: Current System Boot Mode is Legacy. LXPM OS installation only support UEFI Mode. Severity: Warning User Action: 1. Change boot mode to UEFI mode 2. Retry OS deployment. • FQXPMOS0028I: [arg1] OS installed Severity: Info User Action: Information only; no action is required. •...
  • Page 185 User Action: 1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and cables. 2. Ensure device firmware is at the latest level. 3. Retry the test. 4. If the problem persists, contact technical support. •...
  • Page 186 Severity: Error User Action: 1. Do one of the following: – If the affected drive(s) are detected by the system, update the disk drive firmware and reboot the server. – If the affected drive(s) are not detected by the system or failing to respond: a.
  • Page 187 User Action: 1. Check the following Lenovo support site for information on supported RAID adapters. http://www. lenovo.com/us/en/serverproven/index.shtml 2. Ensure RAID adapter, LXPM, and UEFI firmware are at the latest levels. 3. If the problem persists, contact technical support. • FQXPMSR0011K: Failed to change disk drives' state.
  • Page 188 3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter. 4. Reboot the machine and retry to remove the existing virtual disk. 5. If the problem persists, contact technical support. • FQXPMSR0032I: Removed existing virtual disk successfully. Severity: Info User Action: Information only;...
  • Page 189 Severity: Warning User Action: 1. Restart BMC via supported method and reboot the system. 2. Reflash BMC firmware. 3. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC.
  • Page 190 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 191 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 6. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 192 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 193 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, contact technical support. • FQXPMVD0001H: Failed to get VPD data. Severity: Warning User Action: 1.
  • Page 194 ThinkSystem ST250 V3 Messages and Codes Reference...
  • Page 195: Appendix A. Getting Help And Technical Assistance

    Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services, and support are available at: http://datacentersupport.lenovo.com...
  • Page 196: Collecting Service Data

    Collecting service data To clearly identify the root cause of a server issue or at the request of Lenovo Support, you might need collect service data that can be used for further analysis. Service data includes information such as event logs and hardware inventory.
  • Page 197: Contacting Support

    Support when certain serviceable events occur in Lenovo XClarity Administrator and the managed endpoints. You can choose to send diagnostic files to Lenovo Support using Call Home or to another service provider using SFTP. You can also manually collect diagnostic files, open a problem record, and send diagnostic files to the Lenovo Support.
  • Page 198 ThinkSystem ST250 V3 Messages and Codes Reference...

This manual is also suitable for:

Thinksystem st250 v37dcf

Table of Contents