System Requirements; Requirements (For Initialization); Compatible Units; Restrictions - Mitsubishi Electric TG-2000A Operation Manual

Air-conditioner network system integrated centralized control software
Hide thumbs Also See for TG-2000A:
Table of Contents

Advertisement

2. System Requirements

2.1 Requirements (For initialization)

We recommend the following software and hardware when using this application.
Item
CPU
Pentium II 350 MHz or faster
RAM
128 MB or more
256MB or more if running Windows XP
HDD
6 GB or more
1024 × 768 or higher,high color (16bit) or
Resolution
more
Serial port
1
OS
Windows XP Professional
Windows 2000 Professional
Service pack 2 or later
Other
MS-EXCEL 2000/XP
Note:
- Indicates the specifications necessary to set the TG-2000A initial information, and may be different from the actual
operating conditions. There are no site installation usage conditions.
- Refer to the Operation Manual (Site Adjustment) for the site installation usage conditions (recommended system). Also
refer to the relevant instruction manual for the precautions.

2.2 Compatible Units

The TG-2000A has two main functions: air conditioner controller and cost accounting. However, not all functions are available
with all air conditioners. (
Function
Model
Y series
Y series (Cooling Only)
SuperY series
R2 series (Big-R2)
WR2 series
Multi S series
LOSSNAY
OA Processing unit
"A" control type
"K" control type
❈3
❈1: Not applicable to some older models.
❈2: When used with IC attributes, it becomes the same as an indoor unit and billing is possible. When billing is done with watt-hour units,
it is for FAN only. Billing for outdoor units is not possible.
❈3: This does not include "K" control type LOSSNAY.

2.3 Restrictions

The following restrictions apply to the TG-2000A application.
(1) System configuration limits
G-50A
Indoor unit
General equipment (PLC)
General equipment
(IC I/O signal)
Meter
IC: Indoor unit, LC: Lossnay, FU: OA Processing unit, KIC: "K" controller indoor unit, AIC: "A" controller indoor unit
*1 It is only possible to connect a maximum of 32 general equipment units for each PLC for general equipment. The general
equipment No.1** - 1-32 described in section 8.7.4. Even if 33-100 is selected, it cannot be used due to the constraint on the
PLC for general equipment.
*2 A maximum of 350 general equipment units can be connected to IC I/O signal for each G-50. A maximum of 2000 general
equipment units that connect to the IC I/O signal can be controlled using Integrated software TG-2000A.
Requirement
: supported,
: Certain restrictions apply,
Control/Maintenance
(Adapter required)
(A separate watt hour meter is required.
Billing is done with watt-hour units)
(Billing is possible only when used
with IC attributes.
When done individually with watt-hour
units, billing is for FAN only.) ❈2
(Adapter required)
(A separate watt hour meter is required.
Billing is done with watt-hour units)
(Adapter required)
(A separate watt hour meter is required.
Billing is done with watt-hour units)
Number of units
40 units
Max. 50 units / G-50A
Max. 32 units / PLC
Max. 350 units / G-50
Max. 32 units / PLC
Pentium III 500 MHz or faster
256 MB or more recommended
Required for set up of the RS-485 watt-hour meter
English version only
❈ Computer must support each OS.
Necessary when converting characters to multilingualism
: Not supported)
Billing (With WHM)
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
Use Ver. 2.51 or later.
Max 2000 units (including all IC, KIC, AIC, LC, and FU)
Up to a maximum of 640 units (20 general equipment control PLCs) *1
Up to a maximum of 2000 units *2
Up to a maximum of 640 units (5 electric power pulse count PLCs)
3
Recommended
Billing (Without WHM)
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(In block units) ❈1
(Billing is possible only when used
with IC attributes.) ❈2
Notes