Operation on LCD
•
Setting minimum / maximum duration
»
Minimum duration per on-signal: Minimum working hours, heat pump will
work at least the time set here every time been activated. High priority than
other power threshold settings.
»
Maximum duration per day: Maximum working hour limitation per day. High
priority than other power threshold settings.
•
Setting schedule
»
Schedule: Set the heat pump working periods flexibly (heat pump on and off
periods). High priority than other power threshold settings. Two work periods
can be set.
»
Mode Priority: Minimun/Maximum duration > Schedule >Thresholds on/off
Setting User Password
The default password is "0 0 0 0". You can reset the password here.
10.7.2
Advanced Setting
Setting path: Menu>Setting>Advance Setting
Property losses or system damage due to unauthorized access to adjustable
parameters.
• All the adjustable parameters including safety code, grid parameter, export control,
etc can be modified under the permissions of installer password. Unauthorized use
of the installer password by unauthorized persons can lead to incorrect parameters
being input, resulting in power generation loss or violation of local regulation. Get
the installer password from the dealer and never open the password to unauthorzied
person.
Setting Safety Code
In order for the inverter to be able to fed in, the safety code must be set to the installation
site correctly. Here you can set safety code according to different grid connection
regulations in different countries or use User defined according to your needs.
96
===Load Management===
Work Period 1
Start Time
00:00
===Load Management===
Work Period 2
Start Time
00:00
===Load Management===
Work Period 1
End Time
00:00
===Load Management===
Work Period 2
End Time
00:00
NOTICE!
Need help?
Do you have a question about the X3-ULTRA and is the answer not in the manual?
Questions and answers