INSTALLATION & MAINTENANCE MANUAL
7.1.2.5 Sensor Assignment
This function is to assign the specified sensor to the activated zone.
Step1. Select "Sensor Assignment" and press "OK".
Step2. Press " " or " " to select sensor.
Press " " or " " to assign sensor to the target zone.
Step3. Press "OK" to save the setting and return to
Zone Installation Menu. Or press " " to return
to Zone Installation Menu without saving the setting.
NOTES:
Sensor name and description
Sensor Name
RCS1
RCS2
TS1
TS2
IDUS
If only one wired remote controller is connected or Wi-Fi adapter is connected, sensor "RCS2" will not be
displayed.
Multiple sensors can be assigned to one zone.
7.1.2.6 Airflow
This function is to set the airflow value for each activated zone and
common zone(if available).
Step1. Select "Airflow" and press "OK".
Step2. Press " " or " " to select zone and press "OK" to
Step3.
Or press " " to return Zone Installation Menu.
Temperature Sensor of primary WRC
Temperature Sensor of secondary WRC (optional)
Remote Sensor 1 connected to ZIB (THM2, optional)
Remote Sensor 2 connected to ZIB (THM3, optional)
Inlet Air Temperature Thermistor of IDU
28
Common Zone Setup
Zone Actisation
Zone Labeling
Nominate Spill Zone(s)
Sensor Assignment
OK Select
Item
RCS 1
RCS
TS1
TS
IXWS
OK Confirm
Description
Airflow
Minimum Airflow Ratio
Damper Timing
Turn On All Zones
OK Select
Zone
Z1 $ Beroom1
Z2 $ Beroom2
Z3 $ L1K
Zone S
Zone 5
OK Confirm
Zone Installation Menu
(Mon) 16:30
Back
Sensor Assignment
Name
Status
Becroom 1
Zone 1
Becroom
N/A
Main Room
N/A
Hallway
N/A
Living Room
N/A
Back
Zone Installation Menu
Back
Airflow
Airflow (L/s)
Spill
378
275
123
58
78
Back