Advertisement
DIMENSIONS: 9.5" D x 17" W x 27" H
WEIGHT: 20.35 lbs
Replacement FILTER: Filter Model No. FLT9200
Replacement UV-C Bulb: Model No. LB9200
To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.
Improve your indoor air quality with your new Germ Guardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and Charcoal filter to remove odors. UV-C Light Technology enhances germ-killing.
Helps optimize the unit performance and extends the life of the filter by capturing larger dust and allergen particles.
Traps and controls household odors and harmful VOC's in the home.
Reduces allergens.
UV-C Light Technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
Negative ions clear the air of dust, mold spores, pollen, pet dander, and odors. They do this by attaching to these positively charged particles in large numbers. This causes the pollen, mold, etc to become too heavy to stay airborne.
REMOVE ALL BAGS FROM FILTERS BEFORE FIRST USE!
The air purifier is shipped with the filters stored in the filter compartment. The filters are shipped in bags to prevent degradation. Remove filters then remove and discard bags. See instruction for filter/replacement instructions.
Note: Proper filter and front panel installation is necessary for unit to turn on.
Note: The sound will remain off even if the unit is unplugged, and plugged back in.
*Filter Replacement Indicator Light: The REPLACE FILTER light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter. Reset the filter light according to directions.
The air purifier is equipped with a motor protection device. If activated, the overload warning indicator will initiate and cut off the power. An audible warning "ding" will sound 30 times over 15 seconds. To restart the unit unplug the unit then plug back in and power on.
Note: If the unit continues to shut down, there may still be an abnormal condition and the unit may need service. Call Customer Service.
Always unplug the appliance before you clean it.
Never immerse the appliance in water or any other liquid.
Never use aggressive or flammable cleaning agents such as bleach or alcohol to clean any part of the appliance.
Regularly clean the inside and outside of the body to prevent dust from collecting on the inside and outside.
The pre-filter is designed to collect larger dust and debris and should be cleaned monthly or more frequently depending on use. Remove and clean regularly with the brush attachment of your vacuum cleaner. This will remove the lint and dirt and help maintain the life of the filters. (See filter replacement to locate and remove Pre-filter).
The "Replace Filter" indicator will light when it is time to replace your filter. Depending on usage and environmental conditions the filters will last approximately 6 months and should be replaced at the same time. The filter will turn from white to gray/black when it is dirty and needs replacing. It is important to maintain and change the filters to continue to optimize the performance of the air purifier.
DO NOT wash and re-use the filters. Please contact Customer Service or visit our website www.guardiantechnologies.com to purchase a replacement filter.
After the filter OR UV-C bulb has been replaced you will need to reset the indicator light.
UV Bulb Replacement Indicator: The UV light on the display will flash when its time to replace the UV bulb.
Replacement bulb: LB9200
The UV-C Bulb should be replaced every 10 - 12 months depending on use.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.
Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents
What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.
PROBLEM | SOLUTION |
Unit shuts off unexpectedly or does not operate. | Check that the unit is plugged into a working electrical outlet. Check that the filters are installed correctly. Check that the motor protector triggered. Unplug/replug into unit. Check that the Front Panel is latched firmly in place. Call Customer Service. |
No air circulating from unit. | Unplug unit. Check filters. Clean Pre-filter if necessary. Replace filter if necessary. |
Increase in noise level. | Make sure the filters are clean. Replace if necessary. |
Control buttons 'beep' when pushed. | To shut off the 'beeping' sound when buttons are pushed:
|
Red light is on. | Replace filter and reset system. |
Odors and smoke are not removed. | Clean or replace the filters if they appear to be heavily soiled. |
A clicking or ticking sound is heard from the unit. | Clicking sound is emitted when the unit is in the Ion Control Mode, and ticking sound is emitted when the unit is generating ions. Turn off the ION control. |
The discharged air has an aroma or odor. | Check to see if the filters are heavily soiled. Replace the filters. Air Purifiers emit small traces of ozone which may produce an odor. The amount of ozone emitted by the ion generator is below the safety levels, and it is harmless. |
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
Cancer and Reproductive Harm. For more information go to www.P65Warnings.ca.gov.
Please go to www.guardiantechnologies.com to register your product. We consider the registration process important to ensuring superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above.
Additional copies of the instruction manual can be obtained by accessing and printing directly from our website or calling customer service.
Guardian Technologies LLC
26251 Bluestone Blvd. • Euclid, OH 44132
1.866.603.5900 • www.guardiantechnologies.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the AC9200 and is the answer not in the manual?
Questions and answers