Improve your indoor air quality with your new Germguardian Air Purifier. The HEPA filter captures allergens and includes a charcoal filter layer to help reduce household odors. The UV-C light technology helps reduce germs and works with Titanium Dioxide (TiO2) to reduce volatile organic compounds.
The air purifier is shipped with the filter stored in the filter compartment.
The filter is shipped in a bag to prevent degradation. Before using, remove and discard bag.
The air purifier is shipped with the filter stored in the filter compartment.
The filter is shipped in a bag to prevent degradation. Before using, remove and discard bag.
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
Air Quality Monitor senses and detects the amount of particulate matter (PM2.5) in the air.
The bar above the display will change colors, indicating the air quality level in the room.
The particulate matter numeric value (AQI) will be displayed. See values and status ranges in chart below.
Also listed are the color values displayed on the indicator light and the fan speed "AUTO" mode will select based on the particulate matter that is detected.
Light Color | Particulate Matter Value (Range) | Air Quality Status | Auto Fan Speed |
Green | 0-100 | Good | 1 |
Yellow | 101-200 | Average | 2 |
Red | 201-300 | Poor | 3 |
Red | 301-500 | Very Poor | 4 |
The air purifier is equipped with a motor protection circuit. If activated, the overload warning will initiate and cut off the power. An audible warning "chime" will sound for 60 seconds and the AQM light will flash red. To restart the unit, unplug the unit for 10 minutes, then plug back in and power on.
The filter reset indicator light will illuminate when it is time to replace your filter. Depending on usage and environmental conditions the filter will last approximately 6 months. The inside pleats of the filter will turn from white to grey when it is dirty and needs replacing. It is important to maintain and change the filter to continue to optimize the performance of the air purifier.
Do NOT wash and re-use the filter. Please contact Customer Service or visit our website www.guardiantechnologies.com to purchase a replacement filter. Use only Genuine Guardian Technologies replacement parts to optimize the performance of your air purifier.
REMOVE AND REPLACE FILTER
Make sure filter is installed and back panel is closed properly, otherwise unit will not function.
CHANGE BULB INDICATOR
The white light above the UV indicator will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 3 seconds to restart the system.
The UV-C bulb should be replaced every 10 months depending on use.
If the filter is not placed in properly or the filter cover is not secure, the unit will not turn on.
Regularly clean the inside and outside of the body to prevent dust from collecting.
The pre-filter/charcoal layer collects larger dust and debris and should be cleaned monthly or more frequently depending on use. Remove and clean regularly with the brush attachment of your vacuum cleaner. This will remove the lint and dirt and help maintain the life of the filter.
(See filter replacement to locate and clean or remove the filter).
FILTER:
Model No.
FLT9400
UV BULB:
Model No.
LB9000
Check out our
AutoShip&Save
Filter Replacement Program
www.guardiantechnologies.com
To maintain performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.
To purchase visit our website www.guardiantechnologies.com.
Note: Do NOT stick any foreign objects or your fingers inside the unit.
What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.
PROBLEM | SOLUTION |
Unit shuts off unexpectedly or does not operate. | Check that the unit is plugged into a working electrical outlet. Check to see if the motor protector is triggered. Check that the filter and back panel are installed correctly. Unplug/replug into the outlet. Call customer service. |
No air circulating from the unit. | Unplug unit. Check filter. Clean or replace filter if necessary. |
Odors not removed. | Make sure the filter is clean. Replace if necessary. |
Discharged air has an odor. | Check to see if the filter is heavily soiled. Replace if necessary. |
Increase in noise level. | Make sure the filter is clean. Replace if necessary. |
Filter indicator light on display is illuminated. | Replace filter and reset light. |
UV-C indicator light is flashing. | Replace bulb and reset light. |
Air quality status remains poor. | Check to see if the filter is heavily soiled. Replace if necessary. Increase the fan speed to circulate air. |
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
THIS EQUIPMENT SHOULD BE INSPECTED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS ON A REGULAR BASIS TO PREVENT EXCESSIVE ACCUMULATION OF DUST PARTICLES THAT CAN RESULT IN FLASHOVER OR A RISK OF FIRE.
The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m3.
Cancer and Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
The use of this device is a supplement to and not a substitute for standard infection control practices; users must continue to follow all current infection control practices, including those practices related to cleaning and disinfection of environmental surfaces.
Address returns to the attention of: Repair Department, at the address below. Additional questions or comments can be made toll free to the number listed below.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to www.guardiantechnologies.com to register your product. We consider the registration process important to ensuring superior service to our customers, however submitting the registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above.
Additional copies of the instruction manual can be obtained by accessing and printing directly from our website or calling customer service.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the AC9600W and is the answer not in the manual?
Questions and answers