Advertisement
MODEL NUMBER: AC4870
DIMENSIONS: 9.25 in. x 5.5 in. x 21.5 in.
WEIGHT: 8.82 lbs.
INPUT VOLTAGE: 120 V 60Hz 55W
Improve your indoor air quality with your new Germ Guardian® Air Purifying System. Multiple levels of cleaning include a combination HEPA filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.
Pre-Filter*
Captures initial dust and allergen particles.
Charcoal Filter* (aka Activated Carbon)
Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.
HEPA Filter
Captures 99.97% of dust and allergens.
UV-C Light
UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Carbon Filter are combined into one layer that attaches to the Filter.
*Filter must be removed from plastic bag before use.
NOTE: Pre/Charcoal Filter is affixed to HEPA Filter with velcro.
Filter Package includes:
Filter lasts approximately 6-8 months depending on use.
*Filter Replacement Indicator: The HEPA reset light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter according to directions then push and hold Timer Button for 5 seconds to reset filter change indicator.
Depending on usage, filter will last approximately 6 months.
See "Cleaning & Maintaining Filter" for proper care of filter.
![]() | FILTER: Filter ![]() Model No. FLT4825 | ![]() | UV-C BULB (5W): Model No. LB4000 | ![]() | REPLACEMENT CARBON FILTER 4-PACK: Model No. FLT22CB4 |
Check out our AutoShip & Save
Filter Replacement Program ™
www.guardiantechnologies.com
To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.
To Purchase Contact Customer Service
What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.
BEFORE OPERATING THE AIR PURIFIER:
When moving the air purifier, always lift unit by the carrying handle located on the back.
OPERATING THE AIR PURIFIER:
The HEPA reset light on the control panel will illuminate indicating that it is time to replace your filter..
The blue light on the front of air cleaner will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light should remain a constant blue.
The UV-C Bulb should be replaced every 10 - 12 months depending on use.
The air purifier should be cleaned at least once every month and the outer Pre-Charcoal Filter attached to the HEPA Filter should be cleaned every month.
More frequent cleaning may be required depending on environmental conditions.
PRE-/CHARCOAL FILTER
Remove the Pre-/Charcoal Filter from the velcro strips on the HEPA Filter.
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. After cleaning, reattach the Pre-/Charcoal Filter to the HEPA Filter.
HEPA FILTER
Remove the Combination Filter from the back of unit.
Remove the Pre-/Charcoal Filter to expose the HEPA Filter.
When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA Filter is still white, it does NOT need to be replaced.
Do NOT try to wash and re-use the Combination Filter.
Please contact Customer Service at or visit us at www.guardiantechnologies.com to purchase a replacement filter.
Replacement Filter: FILTER B (FLT4825)
NOTE: The Combination Filter is one filter. The multiple layers include: the Pre-/Charcoal Filter and the HEPA Filter.
AIR PURIFIER
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.
Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.
PROBLEM | SOLUTION |
Unit does not operate | Check that the unit is plugged in. Call Customer Service. |
Unit shuts off unexpectedly | Check that the unit is plugged into a working electrical outlet. Check that the HEPA Filter is firmly in place. Check that the Rear Cover is latched firmly in place. Call Customer Service. |
No air circulating from unit | Make sure the filters are clean. Replace if necessary. |
Control buttons 'beep' when pushed | To shut off the 'beeping' sound when buttons are pushed:
|
HEPA reset light on the control panel is illuminating | Time to change the filter. Refer to installation of filter section. |
Replacement Filter: FILTER B
Model No. FLT4825
Replacement UV-C Bulb:
Model No. LB4000
READ AND SAVE THESE INSTRUCTIONS
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m3.
Cancer or Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
This product earned the ENERGY STAR label by meeting strict energy efficiency guidelines set by the U.S. EPA. Room air cleaners have demonstrated the potential for improving air quality and providing health benefits. EPA does not endorse manufacturer claims regarding the degree to which a specific product will produce healthier indoor air. The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model's CADR for Smoke and the electrical energy it consumes, or CADR/Watt.
Customer Service 1.866.603.5900
www.guardiantechnologies.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Guardian AC4870 - GermGuardian 22" Air purifier tower with HEPA filter & UV-C Manual
Advertisement
Need help?
Do you have a question about the AC4870 and is the answer not in the manual?
Questions and answers