Operating Environment; Mechanical Specifications; Dimension Drawings - Siemens SIMATIC NET RUGGEDCOM RS900G Equipment Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS900G:
Table of Contents

Advertisement

Mode
a
Typical.
5.6

Operating Environment

The RUGGEDCOM RS900G is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
Ambient Storage
Temperature
Ambient Relative
Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the RUGGEDCOM RS900G enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the "RUGGEDCOM SFP Transceivers Catalog" for
SFP temperature ratings.
c
Non-condensing
d
Over temperature range of -40 to 85 °C (-40 to 185 °F)
5.7

Mechanical Specifications

Weight
Ingress Protection
Enclosure
5.8

Dimension Drawings

Note
All dimensions are in millimeters, unless otherwise stated.
RUGGEDCOM RS900G
Equipment Manual, 10/2023, C79000-G8976-1025-10
Cable
Connector
Type
Type
(μm)
SM
SC
9μ/125
SM
SC
9μ/125
-40 to 85 °C (-40 to 185 °F)
ab
-40 to 85 °C (-40 to 185 °F)
5% to 95%
c
d
2000 m (6562 ft)
1.2 kg (2.7 lbs)
IP30
20 AWG Galvanized Steel
Tx λ
Tx min
Tx max
a
(nm)
(dBm)
(dBm)
1310
-10
-3
1310
-7
-3
Technical Specifications
5.6 Operating Environment
Rx
Rx
Distance
Sensitivity
Saturation
(dBm)
(dBm)
-22
-3
-24
-3
a
(km)
10
25
23

Advertisement

Table of Contents
loading

Table of Contents