Technical Specifications
This chapter provides important technical specifications related to the device.
5.1
General specifications
Insulation
Overvoltage category
5.2
Power Supply Specifications
Supply Type
HI (125/250
HI (110/230
a
(T) denotes time-delay fuse.
b
Power consumption varies based on the device configuration.
c
Same power supply for both AC and DC.
5.3
Failsafe Relay Specifications
Maximum Switching Voltage
RUGGEDCOM RS950G
Equipment Manual, 10/2023, C79000-G8976-1037-08
Power
Minimum
Input
24 VDC
10 VDC
48 VDC
37 VDC
88 VDC
c
VDC)
85 VAC
c
VAC)
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Class I
OVC II
Maximum
Internal
Input
Fuse Rating
36 VDC
3.15 (T)
72 VDC
3.15 (T)
300 VDC
3.15 (T)
265 VAC
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
Maximum
Isolation
a
Consumption
1.5 kVDC
5.5 kVDC
4 kVAC
Isolation
1500 V
for 1 minute
rms
5
Power
b
10 W
23