Troubleshooting errors on Pelletizer PR750H and PR350H.
•
Solving alarm tag name ID 26 FB_G0x.Build_Pillow ‐ Build pillow
Tag name ID 26
FB_G0x.Build_Pillow ‐ Build
pillow
1. This could be due to pressure drop in the
CO2 installation.
Check that there is sufficient CO2 in the
tank.
2. This could be due to pressure drop in
the CO2 installation.
Check that manual valves are in the
correct
positions.
CO2 gas valves is closed.
CO2 liquid valves is open.
3. This could be due to pressure drop in
the
CO2 installation.
Check that the liquide CO2 filter not is
blocked or dirty.
Yes, the tank is empty.
No, the tank is full.
Yes, a valve is not in the correct
position..
No, all valves is in the correct
position.
Yes, the filter is blocked or dirty.
No, the filter is in order.
Fill the tank.
Go to point 2
Set the valve to the correct position.
Contact Cold Jet
technical support.
Replace the filter or clean it.
Contact Cold Jet technical support.
Reset and restart
the Pelletizer.
Reset and restart
the Pelletizer.
Reset and restart
the Pelletizer.