Table of Contents

Advertisement

For product information,
Owner's Manual translations,
and more, visit
www.MillerWelds.com
Big Blue 600
Air Pak
OM-275624C
Processes
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Stick (SMAW) Welding
TIG (GTAW) Welding
Air Carbon Arc (CAC-A)
Cutting and Gouging
Description
Engine Driven Welder/Generator And
Air Compressor
)
)
File: Engine Drive
2016−12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Big Blue Air Pak 600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Miller Big Blue Air Pak 600

  • Page 1 OM-275624C 2016−12 Processes Processes MIG (GMAW) Welding Flux Cored (FCAW) Welding Stick (SMAW) Welding TIG (GTAW) Welding Air Carbon Arc (CAC-A) Cutting and Gouging Description Engine Driven Welder/Generator And Air Compressor Big Blue 600 Air Pak File: Engine Drive For product information, Owner’s Manual translations, and more, visit www.MillerWelds.com...
  • Page 2 We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING ....... . . 1-1.
  • Page 4 TABLE OF CONTENTS 6-9. Remote Voltage/Amperage Control ............6-10.
  • Page 5: Section 1 − Safety Precautions − Read Before Using

    SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING rom_2015−09 Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if Indicates special instructions. not avoided, will result in death or serious injury.
  • Page 6 D Be alert that welding sparks and hot materials from welding can FLYING METAL or DIRT can injure easily go through small cracks and openings to adjacent areas. eyes. D Watch for fire, and keep a fire extinguisher nearby. D Welding, chipping, wire brushing, and grinding D Be aware that welding on a ceiling, floor, bulkhead, or partition can cause sparks and flying metal.
  • Page 7: Engine Hazards

    1-3. Engine Hazards EXHAUST SPARKS can cause fire. BATTERY EXPLOSION can injure. D Do not let engine exhaust sparks cause fire. D Always wear a face shield, rubber gloves, and D Use approved engine exhaust spark arrestor in protective clothing when working on a battery. required areas —...
  • Page 8: Additional Symbols For Installation, Operation, And Maintenance

    HOT METAL from air arc cutting and MOVING PARTS can injure. gouging can cause fire or explosion. D Keep away from moving parts such as fans, D Do not cut or gouge near flammables. belts and rotors. D Watch for fire; keep extinguisher nearby. D Keep all doors, panels, covers, and guards closed and securely in place.
  • Page 9 BATTERY CHARGING OUTPUT and BATTERY STATIC (ESD) can damage PC boards. EXPLOSION can injure. D Put on grounded wrist strap BEFORE handling Battery charging not present on all models. boards or parts. D Use proper static-proof bags and boxes to D Always wear a face shield, rubber gloves, and store, move, or ship PC boards.
  • Page 10: California Proposition 65 Warnings

    1-6. California Proposition 65 Warnings For Gasoline Engines: Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to Engine exhaust contains chemicals known to the State of cause birth defects and, in some cases, cancer. (California California to cause cancer, birth defects, or other reproduc- Health &...
  • Page 11: Section 2 − Consignes De Sécurité − Lire Avant Utilisation

    SECTION 2 CONSIGNES DE SÉCURITÉ − LIRE AVANT − UTILISATION fre_rom_2015−09 Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives aux précautions de sécurité et au mode opératoire. 2-1.
  • Page 12 D Utiliser une protection différentielle lors de l’utilisation d’un équi- LES ACCUMULATIONS DE GAZ pement auxiliaire. Ne pas tester ni réarmer les prises femelles risquent de provoquer des blessures avec différentiel au régime de ralenti/en basse tension: cela ou même la mort. endommagerait le disjoncteur différentiel, qui ne remplirait plus son rôle de protection contre une électrocution causée par un D Fermer l’alimentation du gaz comprimé...
  • Page 13: Dangers Existant En Relation Avec Le Moteur

    D Porter un équipement de protection pour le corps fait d’un matériau Si des BOUTEILLES sont endomma- résistant et ignifuge (cuir, coton robuste, laine). La protection du gées, elles pourront exploser. corps comporte des vêtements sans huile comme par ex. des gants de cuir, une chemise solide, des pantalons sans revers, des chaussures hautes et une casquette.
  • Page 14: Dangers Liés À L'air Comprimé

    D Pour empêcher tout démarrage accidentel pendant les travaux D Toujours vérifier le niveau de liquide de refroidissement dans le d’entretien, débrancher le câble négatif (−) de batterie de la borne. vase d’expansion (si présent), et non dans le radiateur (sauf si pré- cisé...
  • Page 15: Dangers Supplémentaires En Relation Avec L'installation, Le Fonctionnement Et La Maintenance

    D Pour rechercher des fuites, utiliser de l’eau savonneuse ou D Ne pas approcher les mains, cheveux, vêtements lâches et outils un détecteur à ultrasons, jamais les mains nues. En cas des organes mobiles. de détection de fuite, ne pas utiliser l’équipement. D Avant d’intervenir sur le circuit d’air comprimé, couper l’alimentation électrique, verrouiller et étiqueter l’appareil, D Remettre les portes, panneaux, recouvrements ou dispositifs...
  • Page 16 D Réduire le courant ou le facteur de marche avant de poursuivre le LA SORTIE DE RECHARGE et L’EXP- soudage. LOSION DE LA BATTERIE peuvent D Ne pas obstruer les passages d’air du poste. provoquer des blessures. LES CHARGES ÉLECTROSTATI- La recharge de batterie n’existe pas sur tous les QUES peuvent endommager les modèles.
  • Page 17: Proposition Californienne 65 Avertissements

    2-6. Proposition californienne 65 Avertissements Pour les moteurs à essence : Les équipements de soudage et de coupage produisent des fumées et des gaz qui contiennent des produits chimiques Les gaz d’échappement des moteurs contiennent des pro- dont l’État de Californie reconnaît qu’ils provoquent des mal- duits chimiques dont l’État de Californie reconnaît qu’ils formations congénitales et, dans certains cas, des cancers.
  • Page 18 OM-275624 Page 14...
  • Page 19: Section 3 − Definitions

    Complete Parts List available at www.MillerWelds.com SECTION 3 − DEFINITIONS 3-1. Additional Safety Symbols And Definitions Some symbols are found only on CE products. Warning! Watch Out! There are possible hazards as shown by the symbols. Safe1 2012−05 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. Safe2 2012−05 Protect yourself from electric shock by insulating yourself from work and ground.
  • Page 20 Complete Parts List available at www.MillerWelds.com Do not work on unit if engine is running. Stop engine first. Safe21 2012−05 Do not smoke while fueling or if near fuel. Safe22 2012−05 Stop engine before fueling. Safe23 2012−05 Do not fuel a hot engine. Safe24 2012−05 Use lift eye to lift unit and properly installed accessories only, not gas cylinders.
  • Page 21: Miscellaneous Symbols And Definitions

    Complete Parts List available at www.MillerWelds.com Engine fuel plus flames or sparks can cause fire. Safe45 2012−05 Remove unit from shipping crate. Remove Owner’s Manual from unit. Follow instructions to install muffler. Safe46 2012−05 Read Owner’s Manual. Read labels on unit. Safe47 2012−05 <12.4 V Read Owner’s Manual for battery maintenance information.
  • Page 22 Complete Parts List available at www.MillerWelds.com Suitable For Rated Load Welding In An Engine Speed Environment With Increased Risk Of Electric Shock Rated No−Load Engine Speed Engine RPM Rated Idle Speed Engine Stop Duty Cycle Remote Slow Hours Do Not Switch While Welding Fast Maximum Power...
  • Page 23: Section 4 − Specifications

    Complete Parts List available at www.MillerWelds.com SECTION 4 − SPECIFICATIONS 4-1. Serial Number And Rating Label Locations The serial number and rating information for this product is located on the right side. Use rating label to determine input power requirements and/or rated output.
  • Page 24: Dimensions, Weights, And Operating Angles

    Complete Parts List available at www.MillerWelds.com 4-5. Dimensions, Weights, And Operating Angles Dimensions 53.75 in. (1365 mm) Height (to top of exhaust) 28.5 in. (724 mm) (mtg. brackets turned in) Width 30.75 in. (781 mm) (mtg. brackets turned out) Depth 69.5 in.
  • Page 25: Volt-Ampere Curves

    Complete Parts List available at www.MillerWelds.com 4-7. Volt-Ampere Curves The volt-ampere curves show the A. Stick Mode minimum and maximum voltage and amperage output capabilities of the welder/generator. Curves of all other settings fall between the curves shown. DC AMPERES B.
  • Page 26: Ac Generator Power Curves

    Complete Parts List available at www.MillerWelds.com 4-8. AC Generator Power Curves The AC power curve shows the generator power in amperes. A. Single Phase 4 kW 2 8 0 2 6 0 2 4 0 2 2 0 2 0 0 1 8 0 AC AMPERES B.
  • Page 27: Fuel Consumption

    Complete Parts List available at www.MillerWelds.com 4-9. Fuel Consumption The curve shows typical fuel use under weld or power loads. 4.50 4.25 4.00 3.75 3.50 3.25 With Air Output 3.00 2.75 2.50 2.25 2.00 1.75 No Air Output 1.50 1.25 1.00 0.75 IDLE...
  • Page 28: Section 5 − Installation

    Complete Parts List available at www.MillerWelds.com SECTION 5 − INSTALLATION 5-1. Installing Welder/Generator Airflow Clearance 18 in. Movement (460 mm) 18 in. (460 mm) 18 in. (460 mm) 18 in. 18 in. (460 mm) (460 mm) Location/Mounting Bolting Welding Unit In Unit In Place Place...
  • Page 29: Installing Exhaust Pipe

    Complete Parts List available at www.MillerWelds.com 5-2. Grounding Generator To Truck Or Trailer Frame GND/PE rot_grnd2 2014−11 − 800 652-D Always ground generator frame to frame. Always connect a ground Equipment Grounding Terminal (On vehicle frame to prevent electric wire from the generator equipment Front Panel) shock and static electricity hazards.
  • Page 30: Connecting The Battery

    Complete Parts List available at www.MillerWelds.com 5-4. Connecting The Battery − Tools Needed: 1/2 in. Conn_batt1 2014−11 802 168-E / S-0756-C NOTICE − Lead acid batteries discharge Battery is most easily accessed through Never start the engine when the when stored in any temperature. Units that the rear panel.
  • Page 31: Engine Prestart Checks

    After fueling, check oil with unit on level sur- (see engine maintenance label or en- NOTICE − Diesel engines in Miller equip- face. If oil is not up to full mark on dipstick, ment are meant to operate optimally at mod- add oil (see engine maintenance label).
  • Page 32: Connecting To Weld Output Terminals

    Complete Parts List available at www.MillerWelds.com 5-7. Connecting To Weld Output Terminals Stop engine. Failure to properly connect weld cables may cause excessive heat and start a fire, or damage your ma- chine. Tools Needed: Do not place anything between weld 3/4 in.
  • Page 33: Selecting Cable Sizes

    **Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. ( ) = mm for metric use ***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart). Ref. S-0007-L 2015−02 5-9. Weld Output Terminals Turn off power before connecting to weld output terminals.
  • Page 34: Connecting To Remote 14 Receptacle

    Complete Parts List available at www.MillerWelds.com 5-10. Connecting To Remote 14 Receptacle Socket* Socket Information Not all models have contactor control. See description of front panel controls and circuit diagram. 24 volts AC. Protected by supplementary protector. 24 VOLTS AC Contact closure to A completes 24 volt AC contactor control circuit.
  • Page 35: Connecting To The Air Compressor

    Complete Parts List available at www.MillerWelds.com 5-11. Connecting To The Air Compressor Stop engine and release air pres- sure before servicing compressor. Open Position Closed Position 907712 Air pressure is present at air shutoff The compressor runs and air pressure is The air compressor will not start if still under valve whenever Engine Display on pressure.
  • Page 36: Section 6 − Operating Welder/Generator

    Complete Parts List available at www.MillerWelds.com SECTION 6 − OPERATING WELDER/GENERATOR 6-1. Front Panel Controls (See Section 6-2) 275481-A / 907712 OM-275624 Page 32...
  • Page 37: Description Of Front Panel Controls (See Section 6-1)

    If a remote device connected to Remote meter. When welding is finished, voltmeter Receptacle is faulty or is disconnected NOTICE − Diesel engines in Miller equipment displays weld voltage and then defaults to during operation, the meters display Help are meant to operate optimally at moderate to preset voltage.
  • Page 38: Engine Starting Sequence

    Complete Parts List available at www.MillerWelds.com 6-3. Engine Starting Sequence Wait to Start/Preheating Service Reminder Remaining Remaining Service Reminder Engine Oil Engine Oil Compressor Oil Compressor Oil NOTICE − Do not use ether or other starting To Start: Once this message clears, the engine can fluids.
  • Page 39 Complete Parts List available at www.MillerWelds.com Switch Setting Typical Process Applications (DC Only) MIG solid wire uses a voltage sensing (VS) feeder that does not require a control cable Electrode Hot – MIG VS back to the welder/generator. FCAW (Flux Cored Arc Welding) uses a voltage sensing (VS) feeder that does not re- Electrode Hot –...
  • Page 40: Arc Control

    Complete Parts List available at www.MillerWelds.com 6-5. Arc Control Arc Control Stick Control adjusts Dig when Stick is se- lected on mode switch. When control is set toward minimum, short-circuit amperage at low arc voltage is the same as normal weld- ing amperage.
  • Page 41: Low Open-Circuit Voltage (Vrd) Switch Mode

    Complete Parts List available at www.MillerWelds.com 6-6. Low Open-Circuit Voltage (VRD) Switch Mode Voltage Reducing Device (VRD) Switch The VRD switch can be set for low open-circuit voltage operation in Stick mode. When the unit is con- figured for low open-circuit voltage operation only a low sensing voltage (approximately 15 volts DC) is present between the elec-...
  • Page 42: Lift-Arct Tig With Auto-Stopt

    Complete Parts List available at www.MillerWelds.com 6-8. Lift-Arct TIG With Auto-Stopt Arc Start With Lift-Arc TIG Lift-Arc is used for the DCEN GTAW process when HF Start method is not permitted. Arc Start With Lift-Arc Select Lift-Arc TIG at Process/ Contactor switch.
  • Page 43: Remote Voltage/Amperage Control

    Complete Parts List available at www.MillerWelds.com 6-9. Remote Voltage/Amperage Control Remote 14 Receptacle Connect optional remote control to receptacle (see Section 5-10). When a remote control is connected to the Remote receptacle, the Auto Sense Re- mote feature automatically switches volt- age/amperage control to the remote con- trol.
  • Page 44: Engine Block Heater Operation

    Complete Parts List available at www.MillerWelds.com 6-10. Engine Block Heater Operation Engine Block Heater Plug Use heater to maintain a constant engine coolant temperature. To turn on heater, connect heater Coolant Heater plug to 120 volts AC receptacle. Specifications Do not run engine while en- ±...
  • Page 45: Optional Air Dryer Operation

    Complete Parts List available at www.MillerWelds.com 6-11. Optional Air Dryer Operation The air dryers blow out (purge) mois- ture and debris when the air compres- sor is being used. The air dryer heaters operate whenever the welder/genera- tor is running. See the supplied air dryer Owner’s Manual for air dryer maintenance and service information.
  • Page 46: Section 7 − Operating Auxiliary Equipment

    Complete Parts List available at www.MillerWelds.com SECTION 7 − OPERATING AUXILIARY EQUIPMENT 7-1. North American Auxiliary Power Receptacles 271 858-A Single-Phase Generator Power erator winding from overload. If CB6 (240 V x 13 A) + (120 V x 7 A) = opens, RC1, RC2, GFCI1 and GFCI2 do 4.0 kVA/kW Use GFCI protection when operat-...
  • Page 47: Gfci Receptacle Information, Resetting And Testing

    Complete Parts List available at www.MillerWelds.com 7-2. GFCI Receptacle Information, Resetting And Testing RotGFCI1 2016-12 Use GFCI protection when operat- If a ground fault is detected, the GFCI Reset Resetting GFCI Receptacles ing auxiliary equipment. If unit does button pops out, and the circuit opens to If a GFCI fault occurs, stop engine and dis- not have GFCI receptacles, use disconnect power to the faulty equipment.
  • Page 48: Section 8 − Maintenance

    Complete Parts List available at www.MillerWelds.com SECTION 8 − MAINTENANCE 8-1. Maintenance Label OM-275624 Page 44...
  • Page 49: Cleaning Unit

    Complete Parts List available at www.MillerWelds.com DEUTZ Service: http://www.deutzamericas.com To ensure rapid, efficient service support, you should initially contact your nearest DEUTZ service distributor or dealer. They are staffed with highly qualified parts, service and engine specialists to handle your different needs. The DEUTZ Service Desk enhances this support and can be contacted by completing and submitting the Service Support Form.
  • Page 50: Checking Generator Brushes

    Complete Parts List available at www.MillerWelds.com 8-4. Checking Generator Brushes Stop engine and let cool. Generator Brush Mark and disconnect leads at brush hold- er cap. Remove brushes. Minimum Length: Replace brushes if damaged or if brush 5/8 in. (16 mm) material is at or near minimum length.
  • Page 51: Servicing Air Cleaner

    Complete Parts List available at www.MillerWelds.com 8-6. Servicing Air Cleaner Stop engine. NOTICE − Do not run engine without air cleaner or with dirty element. Engine damage caused by using a damaged ele- ment is not covered by the warranty. The air cleaner primary element can be cleaned but the dirt holding capac- ity of the filter is reduced with each...
  • Page 52: Battery Maintenance

    Complete Parts List available at www.MillerWelds.com 8-7. Battery Maintenance Lead acid batteries discharge when stored in any temperature. Units that are stored should have the battery recharged every three months and before being put into service. To preserve optimum battery performance and life, recharge battery in storage when the open−circuit voltage drops to 12.4 volts DC when measured across the battery terminals.
  • Page 53: Servicing Fuel And Lubrication Systems

    Complete Parts List available at www.MillerWelds.com 8-10. Servicing Fuel And Lubrication Systems Tools Needed: 907712 Stop engine and let cool. To replace fuel filters: To drain sludge from fuel tank: After servicing, start engine and For primary fuel filter, disconnect water sen- check for fuel leaks.
  • Page 54: Engine/Generator Overload Protection

    Complete Parts List available at www.MillerWelds.com 8-11. Engine/Generator Overload Protection 907712 / 803 229 Stop engine. from overload. If F1 opens, weld and gen- Supplementary Protector CB12 erator power is low or stops entirely. If F2 CB12 protects the fuel pump circuit. If When a supplementary protector, cir- opens, weld output is low or stops entirely.
  • Page 55: Voltmeter/Ammeter Help Displays

    Complete Parts List available at www.MillerWelds.com 8-12. Voltmeter/Ammeter Help Displays HL.P Use the Voltmeter/Ammeter help displays to diagnose and correct fault conditions. Display Example When a help code is displayed normally weld output has stopped but generator power output may be okay. To reset help displays, stop unit and then restart.
  • Page 56: Removing Optional Air Dryer For Service

    Complete Parts List available at www.MillerWelds.com 8-13. Removing Optional Air Dryer For Service Follow this procedure whenev- er the air dryer must be re- moved to gain access to the battery. Air Line Timer Control Cable Air Dryer Heater Plug Solenoid LED Disconnect air line from dryer as- sembly bottom inlet.
  • Page 57: Section 9 − Air Compressor Maintenance

    Complete Parts List available at www.MillerWelds.com SECTION 9 − AIR COMPRESSOR MAINTENANCE 9-1. Air Compressor Maintenance Label The air compressor normally requires service at the intervals listed in the maintenance schedule if used in a clean, dry environment. The compressor will require service more often if used in dirty, humid conditions. Notes OM-275624 Page 53...
  • Page 58: Routine Air Compressor Maintenance

    Complete Parts List available at www.MillerWelds.com 9-2. Routine Air Compressor Maintenance See Section 8 for engine/generator maintenance information. Recycle air compressor fluids. Stop engine before maintaining. Service air compressor more often if used in severe conditions. n = Check Z = Change ~ = Clean l = Replace Reference...
  • Page 59: Servicing Air Cleaner

    Complete Parts List available at www.MillerWelds.com 9-3. Servicing Air Cleaner Stop engine. NOTICE − Do not run air compressor without air cleaner or with dirty element. Compressor damage caused by using a damaged element is not covered by the warranty. Compressor Air Cleaner The air cleaner primary element can be cleaned but the dirt holding capac-...
  • Page 60: Compressor Overload Protection

    Complete Parts List available at www.MillerWelds.com 9-4. Compressor Overload Protection Stop engine. When a circuit breaker or fuse opens, it usually indicates a more serious problem exists. Contact Factory Authorized Service Agent. See Section 8-11 for engine/gener- ator overload protection. Circuit Breaker CB15 Circuit breaker CB15 protects the air compressor clutch.
  • Page 61: Servicing Air Compressor

    Complete Parts List available at www.MillerWelds.com 9-5. Servicing Air Compressor Tools Needed: 7/8, 15/16 in. Air Compressor Assembly Right Side High Full Full 907712 / 2555 862-A Stop engine and let cool. Wait 60 sec- To change compressor oil and filter: Add recommended oil until oil level indicator onds for system pressure to drop be- shows system is full (see compressor mainte-...
  • Page 62: Adjusting Compressor Air Pressure

    Complete Parts List available at www.MillerWelds.com 9-6. Adjusting Compressor Air Pressure Check compressor air pressure using air pressure gauge known to be accu- rate. If necessary, adjust air pressure as follows: Tools Needed: Screw 5/16, 3/8 in. Loosen jam nut securing screw. Turn screw clockwise (increase pressure) or counterclockwise (decrease) until pressure is 125 psi (862 kPa).
  • Page 63: Section 10 − Troubleshooting

    Complete Parts List available at www.MillerWelds.com SECTION 10 − TROUBLESHOOTING 10-1. Troubleshooting Also see Voltmeter/Ammeter help displays to assist in troubleshooting weld problems (see Section 8-12). Also see Engine Information Display to assist in troubleshooting engine related problems (see Section 13). A.
  • Page 64 Complete Parts List available at www.MillerWelds.com Trouble Remedy No remote fine amperage or voltage Repair or replace remote control device. control (Continued). Have Factory Authorized Service Agent check current sensing devices, and connections. Constant speed wire feeder does not Reset supplementary protector CB9 (see Section 8-11). work.
  • Page 65 Complete Parts List available at www.MillerWelds.com D. Engine Trouble Remedy Engine will not crank. Supplementary protector CB2 open. Reset CB2. Check fuel level. Check battery connections and tighten if necessary. Check battery, and replace if necessary. Circuit breaker CB10 may be open. CB10 automatically resets when fault is corrected (see Section 8-11). Have Factory Authorized Service Agent check engine wiring harness and components.
  • Page 66: Section 11 − Parts List

    Complete Parts List available at www.MillerWelds.com E. Air Compressor Trouble Remedy Air compressor does not operate; no air Place Air Compressor switch in On position. The air compressor will not start if still under pressure. If pressure at air shutoff valve. compressor is turned off, wait for air pressure to bleed off (about 60 seconds) before turning compressor on again.
  • Page 67 Notes OM-275624 Page 63...
  • Page 68: Section 12 − Electrical Diagrams

    SECTION 12 − ELECTRICAL DIAGRAMS Figure 12-1. Circuit Diagram For Welder/Generator − Part 1 OM-275624 Page 64...
  • Page 69 275578-B OM-275624 Page 65...
  • Page 70 Figure 12-2. Circuit Diagram For Welder/Generator − Part 2 OM-275624 Page 66...
  • Page 71 275578-B OM-275624 Page 67...
  • Page 72: Section 13 − Engine Information Display

    SECTION 13 − ENGINE INFORMATION DISPLAY The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown. 13-1. Display Layout And Controls Engine Information Display Engine Control Switch Function Buttons Yellow LED Red LED The Engine Information Display...
  • Page 73 13-3. RPM Signal Failed Display RPM Signal Failed Display If the operator places the Engine Control switch in the Run/Idle or Run position and does not start the engine, a timer starts. If this condi- tion exists for 5 minutes or longer, the RPM signal failed message ap- pears.
  • Page 74 13-5. 6-Up Display n/min 6-Up Display With Engine RPM 6-Up Display With Air Compressor Engine Coolant Temperature Pressure (Models With Air Engine RPM Compressor) This is the default screen configuration. If Compressor Air Pressure The air compressor must be on and air the operator wants to toggle to the 1-Up Battery Voltage pressure must be available for this display...
  • Page 75 13-7. 1-Up Displays 1-Up Machine Hours Display To increment to the next display, press the Next function button. To return to previous display, press the Previous function button. To return to the 6-Up Display, press the View function button. Machine Hours 15 18 Battery Potential Coolant Temperature...
  • Page 76 13-8. 1-Up Compressor Displays Air Compressor Pressure 1-Up Display To increment to the next display, press the Next function button. To return to previous display, press the Previous function button. To return to the 6-Up Display, press the View function button. Air Pressure display does not appear if the air pressure input is less than 50 PSI.
  • Page 77 13-9. Fuel Level Warnings Fuel level warnings are generat- ed by sensors at the fuel tank. All engine warnings that are dis- played are generated by the en- gine controller (see Sections 13-10 and 13-11). 6-Up Display 1-Up Fuel Level Display Low Fuel Warning The low fuel warning indicator ap- pears and begins to flash when fuel...
  • Page 78 13-10. Warning or Shutdown Display Oil Pressure Display Fault Warning Indicator The warning symbol appears on the display when an engine condition approaches a shutdown condition. 45 60 Fault Shutdown Indicator The shutdown symbol appears on the display when a severe engine fault can cause shutdown.
  • Page 79 Table 13-1. Fault Descriptions This is an abbreviated list of faults. These faults can commonly be remedied by the operator. If other faults appear, contact Factory Authorized Service Agent. Description of Fault Tier 3 or Tier 4 Interim Engines Low oil pressure; warning threshold exceeded High coolant temperature;...
  • Page 80 13-12. Main Menu Access Code Access Code Display An access code is required to gain access to the main menu. This dis- play appears whenever the Menu/ Cancel function button is pressed while in the 1-Up or 6-Up display ENTER PASSWORD Access Code (Password) The factory set access code is 1000.
  • Page 81 13-14. Main Menu Options: Brightness, Contrast, And Units Main Menu Cursor Scroll Function Buttons Use scroll function buttons to move cursor. Select Function Button When the cursor is in desired posi- Brightness " tion, press Select function button to go to sub-menu. Contrast Brightness Menu Display Units...
  • Page 82 13-15. Main Menu Options − Reminders Main Menu Cursor Scroll Function Buttons Use scroll function buttons to move cursor. Select Function Button When the cursor is in desired posi- tion, press Select function button to Brightness go to sub-menu. Contrast Service Reminders Display Units English...
  • Page 83 13-16. Main Menu Options − OEM, Version, Stored Codes, And Language Main Menu Cursor Scroll Function Buttons Use scroll function buttons to move cursor. Select Function Button When the cursor is in desired posi- tion, press Select function button to go to sub-menu.
  • Page 84: Section 14 − Run-In Procedure

    2014−10 NOTICE − Diesel engines in MILLER equipment are meant to operate optimally at moderate to rated load. Using light or no load for extended periods of time may cause wetstacking or other engine damage. Do not idle engine longer than necessary.
  • Page 85: Run-In Procedure Using Load Bank Or Resistance Grid

    14-2. Run-In Procedure Using Load Bank Or Resistance Grid S-0683 / S-0684 Stop engine. Connect load bank or resistor grid to For Resistance Grid generator Side A weld output terminals Set grid switches and then adjust gen- Do not touch hot exhaust pipe, en- using proper size weld cables with correct erator A/V control so load equals rated gine parts, or load bank/grid.
  • Page 86: Section 15 − Air Compressor Tables

    SECTION 15 − AIR COMPRESSOR TABLES 15-1. Flow Of Free Air (CFM) Through Orifices Of Various Diameters Orifice Diameter (in) And Free Air Flow (CFM) Gauge Pressure (psi) 1/64 1/32 3/64 1/16 3/32 3/16 0.027 0.107 0.242 0.430 0.97 1.72 3.86 6.85 0.038...
  • Page 87: Approximate Air Consumption (Cubic Feet) To Operate Pneumatic Equipment At 70-90 P.s.i.g

    15-2. Approximate Air Consumption (Cubic Feet) To Operate Pneumatic Equipment At 70-90 P.S.I.G. Percent Use Factor And Percent Use Factor And MISCELLANEOUS MISCELLANEOUS Compressed Air Consumption (CF) Compressed Air Consumption (CF) PORTABLE PORTABLE TOOLS TOOLS 9 sec 15 sec 21 sec 1 min 9 sec 15 sec...
  • Page 88: Section 16 − Generator Power Guidelines

    SECTION 16 − GENERATOR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welder/generators. Your unit may differ from those shown. 16-1. Selecting Equipment Generator Power Receptacles − Neutral Bonded To Frame 3-Prong Plug From Case Grounded Equipment 2-Prong Plug From Double Insulated Equipment...
  • Page 89 16-3. Grounding When Supplying Building Systems Equipment Grounding Terminal Grounding Cable Use #8 AWG or larger insulated copper wire. GND/PE Ground Device Use ground device as stated in electrical codes. Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.
  • Page 90 16-5. Approximate Power Requirements For Industrial Motors Industrial Motors Rating Starting Watts Running Watts Split Phase 1/8 HP 1/6 HP 1225 1/4 HP 1600 1/3 HP 2100 1/2 HP 3175 Capacitor Start-Induction Run 1/3 HP 2020 1/2 HP 3075 3/4 HP 4500 1400 1 HP...
  • Page 91 16-7. Approximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running Watts Hand Drill 1/4 in. 3/8 in. 1/2 in. Circular Saw 6-1/2 in. 7-1/4 in. 8-1/4 in. 1400 1400 Table Saw 9 in. 4500 1500 10 in. 6300 1800 Band Saw 14 in.
  • Page 92 16-8. Power Required To Start Motor Single-Phase Induction Motor Starting Requirements Motor Start Code KVA/HP 10.0 11.2 12.5 14.0 Motor Start Code Running Amperage Motor HP Motor Voltage To find starting amperage: Step 1: Find code and use table to find kVA/HP.
  • Page 93 16-10. Typical Connections To Supply Standby Power Have only qualified persons perform these connections according to all applicable codes and safety practices. Properly install, ground, and operate this equipment ac- cording to its Owner’s Manu- al and national, state, and lo- cal codes.
  • Page 94 16-11. Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 Volt Loads Use GFCI protection when operating auxiliary equipment. Do not use GFCI receptacles to power life support equipment. Maximum Allowable Cord Length in ft (m) for Conductor Size (AWG)* Current Load (Watts) (Amperes)
  • Page 95 Effective January 1, 2016 (Equipment with a serial number preface of MG or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. Warranty Questions? LIMITED WARRANTY − Subject to the terms and conditions below, 6 Months —...
  • Page 96 Contact the Delivering Carrier to: File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. © ORIGINAL INSTRUCTIONS − PRINTED IN USA 2016 Miller Electric Mfg. Co. 2016−01...

Table of Contents

Save PDF