Codepad Connections For Partitioning - Examples

Figure 10: Connections For CP-5 Master Partitioned (CP500P)
Codepad and CP-5 Area Addressable (CP500A) Codepad
Figure 11: Connections For Two CP-5 Eight Zone Area

Addressable (CP500A) Codepad

Quick Reference Guide
Bosch Security Systems Pty Limited
If the CP-5 Area Addressable (CP500A) codepad is
assigned to Area 1, DIP Switch 1 on the back of the remote
codepad will need to be in the ON position. The following
locations for Output 1 will need to be programmed.
[LOCATION 380 = 6, 381 = 0]
If the CP-5 Area Addressable (CP500A) codepad is
assigned to Area 2, DIP Switch 2 on the back of the remote
codepad will need to be in the ON position. The following
locations for Output 1 will need to be programmed.
[LOCATION 380 = 6, 381 = 1]
Note: The Master Partitioned Keypad requires all DIP
switches set to the 'ON' position to operate correctly.
The following DIP Switch settings and locations must be
programmed for the two CP-5 Area Addressable (CP500A)
codepads to function correctly.
AREA 1 CODEPAD
DIP Switch 1 on the back of the remote codepad will need
to be in the ON position. The following location will also
need to be programmed.
[LOCATION 444, Option bit 2 must be enabled]
AREA 2 CODEPAD - (Output 1)
DIP Switch 2 on the back of the remote codepad will need
to be in the ON position. The following locations for Output
1 will need to be programmed.
[LOCATION 380 = 6, 381 = 1
]