CC408
Quick Reference Guide
EN
Solution 880

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solution 880 CC408 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bosch Solution 880 CC408

  • Page 1 CC408 Quick Reference Guide Solution 880...
  • Page 2 (ii) not commercially exploit or charge any person for the use of the publication; and (iii) not Bosch Security Systems Pty Ltd reserves the right to modify the publication in any way without the prior make changes to features and specifications at any written permission of Bosch.
  • Page 3 3.10.3 Codepad Duress Report ........ 13 3.1.1 Phone Number 1 - Receiver 1 ......9 3.10.4 Codepad Panic Report........13 3.1.2 Phone Number 2 - Receiver 1 ......9 3.10.5 Codepad Fire Report ........13 Bosch Security Systems | 6/04 | 4998152468B...
  • Page 4: Table Of Contents

    3.15.1 Consumer Options 1 ........17 3.15.2 Consumer Options 2 ........17 3.15.3 Consumer Options 3 ........17 3.16 Radio Input Options ........17 3.17 Partioning ............17 3.17.1 Partitioning Options 1........17 3.17.2 Partitioning Options 2........17 Bosch Security Systems | 6/04 | 4998152468B...
  • Page 5 The data in the new location is displayed using the codepad indicators (for example, entering [3 4 #] moves you to LOCATION 034, the beginning of the Subscriber ID Number For Receiver 1). Bosch Security Systems | 6/04 | 4998152468B...
  • Page 6: Location 177 Programming Option Bits

    STAY Mode 1 the installer’s programming commands. 1. Press and hold the [*] key until two beeps sound. 2. Enter your code followed by the [*] key (for example, [2 5 8 0 *]). Bosch Security Systems | 6/04 | 4998152468B...
  • Page 7: Telephone Monitor Mode Zone Leds

    2. Enter your user code. 3. Enter the zone number to isolate followed by the [*] key. Repeat Step 2 if more than one zone must be isolated. 4. Press the [#] key to exit when finished. Bosch Security Systems | 6/04 | 4998152468B...
  • Page 8 Day Alarm – Toggle On/Off Press and hold the [1] key until two beeps sound. Press and hold the [4] key until two beeps sound. The speaker sounds for 2 seconds. Day alarm toggles on or off. Bosch Security Systems | 6/04 | 4998152468B...
  • Page 9 HI-LO handshake (contact ID) Alternate DTMF and reversed decadic 1400 Hz (Ademco TX @ 1900 Hz) 3.1.12 Reserved 2300 Hz (Sescoa TX @ 1800 Hz) No handshake Location 081 to 112 Pager Reserved Bosch Security Systems | 6/04 | 4998152468B...
  • Page 10 RF User #13 245 to 248 3.1.20 Dialler Options 3 Authority Level* RF User #14 250 to 253 Location Authority Level* Default Set DTMP dialling pulses to 1 digit/second Reserved Change decadic dialling to 60/40 Bosch Security Systems | 6/04 | 4998152468B...
  • Page 11 Zone #06 (Default = Instant) Zone Type Zone Pulse Count Reserved Zone Pulse Count Time Reserved Zone Option 1 Reserved Zone Option 2 Split EOL (3K3/6K8) Eight burglary zones Report Code Dialler Options Bosch Security Systems | 6/04 | 4998152468B...
  • Page 12 3 seconds 50 seconds Location 4 seconds 60 seconds Default 5 seconds 90 seconds Unlimited 10 seconds 120 seconds 1 to 15 Number of times dialler operates until 15 seconds 200 seconds lockout Bosch Security Systems | 6/04 | 4998152468B...
  • Page 13: Codepad Medical Report

    Codepad Panic Report Units digit 3.10.13 System Status – Low Battery Restore Location 337 to 338 Report Location Default Tens digit Location 354 to 355 Units digit Location Default Tens digit Units digit Bosch Security Systems | 6/04 | 4998152468B...
  • Page 14: System Status - Access Denied (Code Retry)

    Event Code Telephone line fail Kiss-off received Polarity Fuse fail Time Base AC fail Time Base Multiplier Low battery Time Base Multiplier Horn speaker fail Sensor watch alarm Codepad medical alarm Codepad fire alarm Bosch Security Systems | 6/04 | 4998152468B...
  • Page 15: Polarity (Modes)

    Area 2 – zone unsealed multiplier. For example, if the time base = 2 and Reserved the multiplier = 05, the output operates for 10 Reserved seconds. Reserved Reserved Bosch Security Systems | 6/04 | 4998152468B...
  • Page 16: Pulsing Mode

    System Options 1 Increments of days (tens digit) Location Increments of days Bosch Security Systems smart lockout allowed (units digit) Horn speaker monitor Strobe indication for radio arm/disarm Horn speaker beeps for radio arm/disarm Bosch Security Systems | 6/04 | 4998152468B...
  • Page 17: System Options 2

    Use digit 3 for codepad duress alarm (instead of digit 9) Alarms activate sirens and strobe outputs in STAY Modes 1 and 2 Reserved 3.16 Radio Input Options Location Default Radio receiver (WE800) Latching keyswitch input Momentary keyswitch input Reserved Bosch Security Systems | 6/04 | 4998152468B...
  • Page 18: User Code Area Assignment Programming

    3 – Buttons 1 and 2: Press both buttons at same time to activate Panic alarm. 4 – Buttons 3 and 4: Your security company can program these buttons for optional operation, such as operating a garage door. Bosch Security Systems | 6/04 | 4998152468B...
  • Page 19: Wiring Diagrams

    3 – Zone 8 – N/O 4 – EOL 3K3 9 – N/C 5 – EOL 1K5 10 – 4K7 Figure 5: Wiring Diagram for Keyswitch Zone 1 – Zone 2 – Keyswitch (momentary/toggle) Bosch Security Systems | 6/04 | 4998152468B...
  • Page 20 13 – Piezo siren 22 – Battery 5 – Zone 2 14 – Smoke detector 23 – 18 VAC 1.3 A plug pack 6 – Zone 6 (TF008) 24 – Link between +12 V and Comm Bosch Security Systems | 6/04 | 4998152468B...
  • Page 21 Programming key or hand held programmer – Output termination strip – plugs in here Battery input – Auxiliary module – phone amplifier or – Plug pack input (Bosch TF008) direct link cable – Bosch Security Systems | 6/04 | 4998152468B...
  • Page 22: Codepad Connections For Partitioning

    Output 1 must be programmed: [LOCATION 368 = 6, 369 = 1] [LOCATION 368 = 6, 369 = 1] A master partitioned codepad requires all DIP switches to be set to the ON position. Bosch Security Systems | 6/04 | 4998152468B...
  • Page 23: Connections For Cp-5 Master Partitioned (Cp500P) Codepad And Cp-5 Area Addressable (Cp500A) Codepad

    Figure 10: Connections for Two CP-5 Eight Zone Area Addressable (CP500A) Codepads 1 – DATA 4 – GND 2 – CLK 5 – Area 2 Codepad 3 – +12V 6 – Area 1 Codepad Bosch Security Systems | 6/04 | 4998152468B...
  • Page 24 Bosch Security Systems 25 Huntingwood Drive Huntingwood, 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2004 Bosch Security Systems 4998152468B S1920057 Issue 1.62...