Hydraulic System Maintenance; Auxiliary Hydraulic Fluid Specification; Checking The Auxiliary Hydraulic Fluid Level; Changing The Auxiliary Hydraulic Reservoir Fluid And Filter - Toro 29516 Operator's Manual

24in stand-on aerator
Hide thumbs Also See for 29516:
Table of Contents

Advertisement

Hydraulic System
Maintenance
Auxiliary Hydraulic Fluid
Specification
Hydraulic fluid type: AW-32 hydro fluid
Checking the Auxiliary
Hydraulic Fluid Level
Note:
The machine is shipped with hydraulic fluid
in the reservoir.
1.
Run the machine for approximately 15 minutes
to purge any extra air out of the hydraulic
system.
2.
Completely raise and lower the tines 3 times to
purge the air.
3.
Shut off the engine, remove the key and allow
the machine to cool.
4.
Remove the cap and check the hydraulic-fluid
level in the reservoir.
Note:
The hydraulic-fluid level should cover
the word FULL COLD that is embossed into the
baffle of the reservoir
(Figure
50).
1. Cap
2. Auxiliary hydraulic
reservoir
5.
If necessary, add the specified hydraulic fluid
to the reservoir until the fluid covers the FULL
COLD fluid level on the baffle
Note:
If the fluid is at ambient-air temperature,
about 24°C (75° F), fill only to the FULL COLD
level.
6.
Install the hydraulic reservoir cap
and tighten it until snug.
Note:
Do not overtighten the reservoir cap.
Changing the Auxiliary
Hydraulic Reservoir Fluid
and Filter
Draining the Auxiliary Hydraulic
Fluid
1.
Run the machine for approximately 15 minutes
to purge any extra air out of the hydraulic
system.
2.
Completely raise and lower the tines 3 times to
purge the air.
41
Figure 50
3. Hot fluid level (baffle)
4. Cold fluid level (baffle)
(Figure
50).
(Figure
g266183
g266182
50)

Advertisement

Table of Contents
loading

This manual is also suitable for:

29517

Table of Contents