Download Print this page

Samsung CNH HDB Series Technical Data Book page 101

Single, low ambient line up for america r410a, cooling only
Hide thumbs Also See for CNH HDB Series:

Advertisement

Installation
Wall Mounted Type CNH18/24ADB(AC018/024BNADCH/AA)
Outdoor
Unit
Indoor Power
Power supply
208 to 230V, 60Hz
0.0012in² ↑(0.75mm²↑), 2 wires
Indoor Unit
1(L) 2(N)
F1
F2
Cable clamp
N
1(L) 2(N) L
F1 F2
Cable
Tie
Cable
clamp
Main power cable
Communication cable
Indoor power supply
Max/
Indoor power cable
Min(V)
0.0012in² ↑(0.75mm²↑),
±10%
3 wires
Communication cable
AC power, Communication : M4 screw
1(L)
2(N)
F1
F2
0.54(13.8)
0.41(10.3)
Tightening torque
N‧m
M3.5
0.8 to 1.2
M4
1.2 to 1.8
(1N‧m=10kgf‧cm)
Power supply cords of parts of appliances for outdoor use
shall not be lighter than polychloroprene sheathed flexible
cord. (Code designation IEC:60245 IEC 57 / CENELEC:
H05RN-F)
Since it has the external power supply, refer to the
outdoor unit installation manual for MAIN POWER.
CAUTION
When installing the indoor unit in a computer room or
network room, use the double shielded communication
cable (tape aluminum / polyester braid + copper) of
FROHH2R type.
(Unit: inch (mm))
lbf.ft
0.59 to 0.89
0.89 to 1.1

Hide quick links:

Advertisement

loading