Id Pushbutton - Samsung HARMAN AMX MU Series Instruction Manual

Automation controllers
Table of Contents

Advertisement

1. Strip 0.25 inch (6.35mm) of insulation off all wires.
2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector
types described in this section).
3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively, as doing so may
strip the threads and damage the connector.

ID Pushbutton

All MU-series controllers feature an ID pushbutton which you can use to reset the default settings on the controller or
restore the controller to its factory firmware image.
The ID Pushbutton functionality is as follows:
A Quick press will send out an HControl "Identify" message
Press & hold for 10 seconds will perform a configuration factory reset
Press & hold for 20 seconds will perform a configuration factory reset including return to factory firmware.
A factory reset performs the following operations:
All user scripts (Python, Groovy, JavaScript) and libraries are deleted
All manually installed extensions are uninstalled
All manually configured repositories are removed
All device instance files are removed
All Plug-in configuration items are reset to their defaults
All SMTP servers are removed
ICSP authentication/encryption returns to "off"
All bound NDP devices are unbound (TBD)
All IRL files are removed
All installed HiQnet AudioArchitect files are removed
HiQnet node id returns to default
All Duet module .jar files are removed
Network configuration is returned to defaults
LAN returns to DHCP client mode, hostname returns default value
ICSLan returns to DHCP Server mode on octets 198.18.0.x
802.1x is disabled
Network time is disabled
NTP servers are cleared
Time will coast using the real-time clock
Time zone returns to default
User accounts are deleted
The default credentials of "admin" with default "password" are restored
"support" user is disabled
Any configured syslog server is disabled and cleared
Any configured flash media logging is disabled
Any manually installed certificates are removed
Factory certificates for HControl, HTTPS and Secure ICSP are restored
Device control ports return to default state
IRL files are cleared
Serial port comm parameters return to their default (9600, 8 data bits, 1 stop bit, No parity, 422/485 disabled)
All I/O's return to digital input mode with default threshold values