  • Page 1 CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners Wireless Remote Controller PAR-SL101A-E Series OPERATION MANUAL / INSTALLATION MANUAL FOR USER / FOR INSTALLER English...
  • Page 2: Table Of Contents

    Contents Installation Manual For safe and correct use, read this manual and the indoor unit installa- tion manual thoroughly before installing the air-conditioner unit. 1. Safety Precautions ............. 1 6. Function settings ............7 2. Confirming the Supplied Parts ........2 6.1.
  • Page 3: Confirming The Supplied Parts

    1. Safety Precautions CAUTION ■ Do not install in any place exposed to flammable gas leakage. • Flammable gases accumulated around the body of PAR-SL101A-E may cause an explosion. ■ Do not use in any special environment. • Using in any place exposed to oil (including machine oil), steam and sulfuric gas may deteriorate the performance significantly or give damage to the component parts.
  • Page 4: Installation

    3. Installation ■ Use the remote controller holder that is provided to avoid misplacing the remote controller. ■ Install the remote controller in a location that meets the following conditions. • Out of the direct sun light • Away from any heat sources •...
  • Page 5: Various Settings

    4. Various settings The following initial and function settings can be changed with this remote controller. Pressing the Pressing the button Initial settings Stop operation Temperature unit ( button) while the function No. “1” is lit button Time display button) Auto mode button) Pair No.
  • Page 6: Initial Setting

    5. Initial setting The following settings can be made in the initial setting mode. Item Setting Fig. 5-3 Temperature unit ºC/ºF Time display 12-hour format/24-hour format AUTO mode Single set point/Dual set point Pair No. 0–3 Backlight On/Off 5.1. Switching to the initial setting mode (Fig.
  • Page 7: Changing The Pair No

    5. Initial setting 5.5. Changing the pair No. (Fig. 5-1, Fig.5-3 E) Press the button 4. • Set the pair number to "0"–"3". (The factory setting is “0”.) Indoor unit setting Mr. Slim CITY MULTI Indoor PC board Pair No. of wireless remote SW22 settings Indoor PC board jumper wire (J41 and J42 settings) controller...
  • Page 8: Changing The Backlight Setting

    5. Initial setting 5.6. Changing the backlight setting (Fig. 5-1, Fig. 5-3 F) Press the button 9. • Pressing the button 9 changes the setting ). (The factory setting is “ON”.) : The backlight comes on when a button is pressed.
  • Page 9: Separate Settings Mode 1

    6. Function settings 6.3. Separate settings mode 1 (Fig. 6-2, Fig. 6-3) You can also set the functions as necessary for the indoor unit that you want to operate. 1) Operation mode setting (The factory setting is "01".) 1. Press the button 5.
  • Page 10: Completing The Settings

    6. Function settings 4) Louver setting (The factory setting is “01”.) 1. Press the button 9. • The louver G blinks. 2. Press the button 4 to select the setting number D. Louver setting G Setting No.D No display (Disabled) (Enabled) •...
  • Page 11: Separate Setting Mode 2

    6. Function settings 6.5. Separate setting mode 2 (Fig. 6-4, Fig. 6-5) 1) Switching to the separate setting mode 2 After switching to the function setting mode (6.1.), hold down the button 2 for 5 seconds. • The pattern number K blinks. 2) Horizontal airflow direction setting (The factory setting is “01”.) 1.
  • Page 12: Completing The Setting

    6. Function settings 5) Automatic filter elevation panel operation set- ting (The factory setting is “01”.) 1. Press the button 4. • The automatic filter elevation panel opera- tion M blinks. 2. Press the button 4 to select the setting number D.
  • Page 13: Service

    7. Service 7.1. Test run (Fig. 7-1) 1. Press the button 1 to stop the air conditioner. • If the weekly timer is enabled ( A is on), press the button 2 to disable it ( A is off). 2. Press the button 3 for 5 seconds.
  • Page 14 7. Service Refer to the following tables for details on the check codes. * A receiver adapter (MA type) cannot be used. [Output pattern A] Beeper sounds Beep Beep Beep Beep Beep Beep Beep OPERATION · · · Repeated INDICATOR lamp blinking Approx.
  • Page 15 7. Service ■ Mr. Slim output contents [Output pattern A] Errors detected by indoor unit Wired remote Wireless remote controller controller Symptom Remark Beeper sounds/OPERATION INDICATOR lamp blinks Check code (Number of times) Intake sensor error P2, P9 Pipe (liquid or 2-phase pipe) sensor error E6, E7 Indoor/outdoor unit communication error Drain sensor error/Float switch connector open...
  • Page 16 7. Service ■ CITY MULTI output contents [Output pattern A] The abnormal unit (attribute) is an indoor unit, LOSSNAY unit, or outdoor air processing unit. [Output pattern B] The abnormal unit (attribute) is an outdoor unit or other unit (a unit other than an indoor unit, LOSS- NAY unit, or outdoor air processing unit).
  • Page 17: Unit Function Selection

    7. Service 7.3. Unit function selection This setting method is for Mr. Slim. For CITY MULTI models, set the DIP switches on the indoor PC board and outdoor PC board. To set the DIP switches, refer to the technical materials for the CITY MULTI models. Set the functions as necessary using the remote controller.
  • Page 18 7. Service Function selection procedure (Fig. 7-3, 7-4) First, it is important to understand the procedure for the function selection. The following procedure explains how to set "LOSSNAY connectivity" in table 1 to "Supported (indoor unit is not equipped with outdoor-air intake)" as an example. For the actual operations, refer to the following procedure.
  • Page 19 7. Service 5. Press the button 4 to set the mode number. • While pointing the wireless remote controller toward the receiver, press the button 5. (The setting number blinks.) At this time, the beeper sound and OPERATION IN- DICATOR lamp blinking pattern indicate the current setting number for the selected mode number.
  • Page 20 This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN VH79A034H01 Printed in Thailand...