The presence detector has sensors for presence;
Temperature and brightness detection which are suitable for connection to proprietary bus systems. The output of the signals takes place by analog voltage values 0-10V (10LUX = 0.1 V, 0.5°C = 0.1 V) at the output terminals. For evaluating the motion detection a floating reed relay is still available.
Work on the mains supply may only be carried out by qualified professionals or by instructed persons under the! direction and supervision of qualified skilled electrical personnel in accordance with electrotechnical regulations.
Disconnect supply before installing!
This device is not suitable for disconnection.
A circular opening of diameter 68 mm must first of all be produced in the ceiling.
Having connected up the cables in accordance with regulations, the detector is inserted into the opening as shown in the drawing opposite and fixed into position with the assistance of the spring clip.
Position LED's and potentiometer
Potentiometer (A): Potentiometer Follow-up time
Potentiometer (B): Potentiometer Brightness adjustment LUX-0
Potentiometer (C): Potentiometer Brightness adjustment LUX-I
Potentiometer (D): Potentiometer Temperature setting TEMP
LED I: red
Sensor (LUX-0): Brightness
Sensor (LUX-I): Brightness
Sensor (1): Temperature
The product enters an initial 60-second self-test cycle, when the supply is first connected. During this time the device does not respond to movement and stays on.
Adjustment follow-up time "motion detection"
The follow-up time can be set from 1 sec to 30 min.
Brightness adjustment LUX-0
The potentiometer LUX-0 can set fine adjustment of the light output value
Brightness adjustment LUX-I
The potentiometer LUX-I can set fine adjustment of the light output value
Temperature Offset
With potentiometer TEMP, an offset can be set (+4°C to -4°C)
With the potentiometers LUX 0 and LUX-I, the output voltage of the 0-10V output of + / - 10% change and the slope of the lux / VDC curve can be adjusted. Losses caused by cable lengths can be compensated.
The brightness value output corresponds each 10LUX = 0.1 V
The brightness measurement includes the area between 0 LUX = 0V to 10V = 1000 lux
An update of the measured values are approximately every 0.5 s
With the TEMP potentiometer output voltage can be offset between -4ºC (-0.8V) to 4ºC (0.8V) regarding to the temperature measured by the temperature sensor in order to compensate the measurement of the sensor depending where the device is placed. The neutral position of the potentiometer is marked with an arrow where the 0 offset is.
The temperature value output corresponds each 0.5°C = 0.1 V. The temperature range is the range between 0°C = 0 V and goes to 50°C = 10V is done to update the readings approximately every 10s
The motion sensor turns on the relay with active motion and turns off when the unit detects no movement and the follow-up time has expired. After switching off the motion detection for about 2s is deactivated to prevent an unwanted power up again. An update of the measured values are approximately every 20ms.
If the detection zone is too large, or areas covered that should not be monitored, use the blinds to reduced or limited those areas.
Power supply: 12-48 VDC
Power consumption: < 1W
Ambient temperature: 0°C to +50°C
Degree of protection / class: IP20 / II
Settings: Potentiometer and Remote control
LUX-/TEMP-Output: 0-10 V ± 200 mV, 10 mA max.
Light values
Sensitivity: 0 - 1000 Lux, ± 20 Lux
Light measurement: ca.10 mV/Lux
Temperature values: 0°C - +50°C, ± 0,5°C
Sensitivity
Temperature values: ca.200 mV/°C
Area of coverage: circular 360°
Range of coverage Ø H 2,50 m / T = 18°C: tangential 10 m / frontal 6 m
Recommended height for mounting: 2 - 3 m
Light measurement: mixed light
Motion detector: potential-free contact NO
Contact load: 0-48 VDC, 100mA, cos φ=1
Time setting (Channel 1): Potentiometer 1s. - 30 min.
Remote control 5s - 1h or Impulse function
Connection: single wire (not stranded) 0,34... 1,5 mm² single conductor
Cable length: max. 100 m*
*Avoid parallel wiring to power cables. If a separated installation is not possible, the use of shielded cables is recommended
Dimensions H x Ø [mm]: 83 x 83 mm
Visible portion when built into ceiling: 20 x 83 mm
Sensor and power supply in one case
Declaration of Conformity:
This product respects the directives concerning
Typ | FC |
PD2N-LTMS-RR | 92119 |
LUXOMAT® Remote control:
IR-LTMS (incl. wall bracket) - 92185
Accessory:
BSK Ball basket guard - 92199
LED function indicators | |
Operating state | LED function indicators |
Initialization | 60s initialization, red flashes 2x in the second |
Active | red lights on when motion is detected |
Resetting the Temperature potentiometer on neutral, LED lights up for 2 seconds.
X1, X2: Evaluation units/-devices
Explanation of the remote control button functions
Factory setting: In this setting, the light measurement take place over light sensor LUX-0
In this setting, the light measurement takes place via light sensor LUX-I
In this setting, the light measurement take place over an average of the two light sensors.
Impulse function
Follow-up time
Reset in the open state: Deletes all values set with the remote control, Potentiometer settings apply.
Resetting when closed: End all active follow-up Timer
Increase the temperature offset to +1°C (0,2V)
Increase the temperature offset to +0,5°C (0,1V)
Reduce the temperature offset to -1°C (0,2V)
Reduce the temperature offset to -0,5°C (0,1V)
This function permanently blocks the reception of remote control signals. This function can be activated within 5 sec. after closing the detector. To unlock see Reset the permanent sabotage protection
Normal sensitivity
High sensitivity
Activate or deactivate the LED display
Test mode, only dependent on movement. With every movement switches the light for 2 seconds ON, then for 2 sec. OFF. After 3min. Test mode is automatically terminated and returns to normal operating mode.
To turn the light on and off manually by pressing the button briefly. The light will remain on or off as people are detected plus the follow-up time.
If the permanent sabotage protection is activated, the detector can be released again as follows:
The product PD2N-LTMS-RR used a a light sensor, to determine the brightness value by default, which is located in the outer cover ring. Through this arrangement, results a selective range, where the light measurement takes place. For a enlargement of the selective measurement range, a second light sensor (behind the lens) can be switched on or get individually activated by the optional remote control.
Sensor (LUX-0) Light sensor in the cover ring (Factory setting)
Sensor (LUX-1) Light sensor behind the lens
LED function indicators | |
Operating state | LED function indicators |
Remote control signal | LED flashes briefly |
Detector close | LED shines 5 sec. |