This user manual contains important information about your combination smoke and carbon monoxide alarm's operation. То ensure proper use and trouble-free operation, please read this manual carefully and store it in а safe place for future reference.

Introduction

AII X-Sense combination smoke and carbon monoxide alarms conform with regulatory requirements, including EN 14604 and EN 50291 Standards and are designed to detect both smoke and carbon monoxide.

This unit adopts photoelectric technology to detect smoke which is generally more sensitive than ionization technology. lt is effective at detecting large particles, which tend to bе produced in greater amounts bysmoldering fires. These types of fires may smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.

Carbon monoxide (СО) is odorless, tasteless and invisible - it's а silent killer. Using electrochemical sensing technology, this unit can detect increased levels of carbon monoxide early, protecting your family from the dangers of carbon monoxide.

  • The installation of the apparatus should not bе used as а substitute for proper installation, use and maintenance of fuel-burning appliances including appropriate ventilation and exhaust systems.
  • This apparatus is to bе installed byа competent person.
  • lt is not tested for use in а caravan or boat.

NOTE: For maximum protection, use smoke and СО alarms оn each level and in every bedroom of your home.

NEVER IGNORE THE SOUND OF THE ALARM!

Determining what type of alarm has sounded is easy with your X-Sense combination smoke and carbon monoxide alarm. The buzzer will inform you of the type of situation occurring.

Package Contents

1 х Alarm Unit
1 х Mounting Bracket
3 х Screws
3 х Anchor Plugs
1 х User Manual

Technical Specifications

Power Supply 10-year sealed lithium battery
Sensor Type Smoke: Photoelectric
CO: Electrochemical
Product Lifespan 10 years
Safety Standard EN 14604:2005 and EN 50291-1:2018
CO Sensitivity 30 ppm: > 120 minutes
50 ppm: 60-90 minutes
100 ppm: 10-40 minutes
300 ppm: < 3 minutes
Operating Temperature 4.4-37.8°C (40-100°F)
Operating Relative Humidity 10%-85% RH (non-condensing)
Alarm Loudness ≥ 85 dB at 3 m (10 ft) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration ≤ 9 minutes
Operating Frequency 868 MHz
Maximum Number of Interconnected Units 24 wireless units (only compatible with X-Sense wireless alarms)
Transmission Range Over 250 m (820 ft) in open air

NOTES

  1. Battery life is calculated оn the current ratings in the standby mode with weekly testings. lf its operation mode changes to аn alarming condition, the battery life will bе decreased accordingly.
  2. This alarm functions between 4.4-37.8°С (40-100°F). Prolonged exposure to lower or higher temperatures can reduce battery life and affect device performance. We do not recommend operating the device beyond its temperature range.

Product Overview


THIS COMBINATION SMOKE AND CARBON MONOXIDE ALARM IS DESIGNED FOR INDOOR USE ONLY. DO NOT EXPOSE ТО RAIN OR MOISTURE. DO NOT KNOCK OR DROP THE ALARM. DO NOT OPEN OR TAMPER WITH THE ALARM AS THIS COULD CAUSE MALFUNCTION.

Product Overview

Test/Silence Button

SC06-W: The Test/Silence button is used to test the unit's electronics and to silence the unit during an alarm. When testing the alarm weekly, press and hold the test button until you hear а short beep, indicating that the alarm has entered the test mode. Please refer to the "Alarm Test" section for further information. The alarm goes back to the standby mode after testing.

SC07-W: The Test/Silence button is used to test the unit's electronics and to silence the unit during an alarm. When testing the alarm weekly, you should first wake up your alarm bypressing the test button; once the alarm has woken up, the LCD display will activate, then press and hold the test button again until you hear а short beep, indicating that the alarm has entered the test mode. Please refer to the "Alarm Test" section for further information. The alarm goes back to the standby mode after testing. То save power, the alarm is designed to automatically turn off the LCD display if there has been no operation for 5 minutes.

NOTE: After а test has begun, the alarm will sound and the LED will flash red. This does not indicate that smoke/CO is present.

Silence Mode

Smoke Silence Mode: Press the test button during an alarm to have the unit enter silence mode for 9 minutes. lf the smoke concentration has reached an alarm level, after the silence time has expired, this unit will continue to alarm until the smoke concentration decreases to а safe, low level. Otherwise, the alarm will enter the normal mode after 9 minutes.

СО Silence Mode: Press the test button during an alarm to have the unit enter silence mode. lf the СО density still exceeds the alarm threshold, the unit will re-enter alarm state. Otherwise, the unit will exit the silence mode after 9 minutes and resume normal operation. lf the СО concentration is above 300 ppm, the silence function cannot bе enabled.

NOTES

  1. You can silence all interconnected units by pressing the Test/Silence button оn one of the units. lf one unit is still alarming, it is the initiating unit (the unit that detected danger); to silence all interlinked units, you must also press the Test/Silence button оn the initiating unit.
  2. While interconnected, the initiating unit cannot bе triggered again during the 9-minute silence duration. However, all other interconnected units can bе triggered again if they detect danger during the silence mode.

Buzzer

The alarm will sound when there is smoke or СО present, when you test the alarm, and when there is а fault.

LED lndicator

The LED indicator will flash in conjunction with the buzzer. Therefore, it will flash during the following states: when powering on, in standby mode, during smoke or СО alarm states, when exiting an alarm state, during test mode, when there is low battery, in silence mode, when there is а fault and when the unit is at the end of its life.

Low Battery

The LED indicator will flash yellow together with one beep every 60 seconds.

THE UNIT MUST ВЕ DEACTIVATED (see "Deactivation of the Alarm" section) AND REPLACED AS SOON AS POSSIBLE.

lf you press the test button when there is low battery, the low battery signal will temporarily cease for 10 hours.

End of Life

Once the maximum lifetime (10 years) is reached, the alarm will deliver 3 beeps and the LED indicator will flash yellow 3 times every 60 seconds. This end-of-life signal can bе temporarily silenced for 22 hours by pressing the test button.

The end-of-life silence feature can only bе used for а total of 30 days. After 30 days, the end-of-life signal cannot bе silenced.

СО Alarm Levels

This X-Sense combination smoke & carbon monoxide alarm is programmed to sound an alarm at the following СО concentrations within the time periods listed:
30 ppm over 120 minutes,
50 ppm for 60-90 minutes,
100 ppm for 10-40 minutes,
and 300 ppm for 0-3 minutes.

SC06-W: When СО is detected and the alarm sounds, the LED indicator will f1ash red and the alarm will issue 4 short beeps, repeating the cycle every 5.8 seconds.

SC07-W: When СО is detected and the alarm sounds, the СО concentration will bе displayed on the LCD and а blue backlight will bе lit. The LED indicator will f1ash red and the alarm will issue 4 short beeps, repeating the cycle every 5.8 seconds.

СО Concentration and Symptoms

The table below shows the effects of different levels of СО poisoning on the body:

Parts per Million (PPM) Effects on Adults
100 Slight headache, nausea, fatigue (flu-like symptoms).
200 Dizziness and headache within 2-3 hours.
400 Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to life after over 3 hours of exposure.
800 Severe headaches, convulsions, vital organ failures. Death possible within 2-3 hours.


THIS DEVICE IS DESIGNED ТО PROTECT INDIVIDUALS FROM ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT А MEDICAL PRACTITIONER.

Different working modes and states (SC06-W)

Mode LED Indicator Audible Alarm Remarks
Powering On Runs through 8 cycles (yellow/green/red) in sequence. 1 quick beep. Make sure the alarm is properly attached to the mounting bracket.
Standby Mode Flashes green once every 60 seconds. None. None.
Alarm Mode Unit detects smoke and initiates an alarm. Flashes red 3 times every 1.5 seconds. 3 long beeps every 1.5 seconds. Dangerous smoke concentration is detected. Open nearby windows and doors, and immediately move to fresh air.
Unit detects CO and initiates an alarm. A CO concentration ranging from 30 to 999 ppm has been present for a certain time period. The LED indicator flashes red 4 times every 5.8 seconds. 4 quick beeps repeating every 5.8 seconds. Dangerous CO concentration is detected, and has reached the alarm status. Open nearby windows and doors, and immediately move to fresh air.
All other interconnected units in the network. The LED flashes red and green 3 times sequentially every 1.5 seconds. 3 long beeps every 1.5 seconds. Dangerous smoke concentration is detected by the initiating unit in the network. Please find the initiating unit and take action.
The LED flashes red 4 times, then the green LED flashes once every 5.8 seconds. 4 quick beeps repeating every 5.8 seconds. Dangerous CO concentration is detected by the initiating unit, and has reached the alarm status.
Please find the initiating unit and take action.
Unit detected smoke and initiated an alarm. The LED indicator flashes green once every second for 5 seconds. None. Alarm cancellation: when the smoke concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Unit detected CO and initiated an alarm. The LED indicator flashes green once every second for 5 seconds. None. Alarm cancellation: when the CO concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Test Mode Test a single unit. 2 sets of 3 red flashes followed by 2 sets of 4 red flashes. 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps. Press the Test/Silence button.
Test all interconnected units. The LED indicator flashes red rapidly. Continuous beeping until you release the Test/Silence button. Initiating alarm.
Hold down the Test/Silence button on one unit in the network.
The LED flashes red and green sequentially. Other interconnected alarms in the network.
Silence Mode Flashes red 3 times every 1.5 seconds. None. Smoke silence mode: After 9 minutes, the unit will exit silence mode.
Flashes red 4 times every 5.8 seconds. None. CO silence mode: After 9 minutes, the unit will exit silence mode.
Flashes yellow once every 60 seconds. None. Silence mode during low battery: After 10 hours, the unit will exit silence mode.
Flashes yellow 3 times every 60 seconds. None. Silence mode during the end of cycle: After 22 hours, the unit will exit silence mode.
Flashes green 3 times. None. Exiting silence mode.
Low Battery Flashes yellow once every 60 seconds. One beep every 60 seconds. Replace the unit immediately.
Fault Flashes yellow 2 times every 60 seconds. 2 beeps every 60 seconds. Please clean your alarm and see if it is working normally. If the unit has malfunctioned, it must be replaced immediately.
End of Life Flashes yellow 3 times every 60 seconds. 3 beeps every 60 seconds. Replace the unit immediately.

LCD Display {SC07-W)

While detecting СО, the LCD will display different indications to help you understand what to do, as shown below:

Mode LCD Display LED Indicator Audible Alarm Remarks
Powering On Runs through 8 cycles (yellow/ green/ red) in sequence. 1 quick beep. Make sure the alarm is properly attached to the mounting bracket.
Standby Mode Flashes green once every 60 seconds. None. None.
Alarm Mode Unit detects smoke and initiates an alarm. - Flashes red 3 times every 1.5 seconds. 3 long beeps every 1.5 seconds. Dangerous smoke concentration is detected. Open nearby windows and doors, and immediately move to fresh air.
Unit detects CO and initiates an alarm. A CO concentration ranging from 30 to 999 ppm has been present for a certain time period. The blue backlight is lit, and the LED indicator flashes red 4 times every 5.8 seconds. 4 beeps repeating every 5.8 seconds. Dangerous CO concentration is detected, and has reached the alarm status. Open nearby windows and doors, and immediately move to fresh air.
All other interconnected units in the network. - The LED flashes red and green 3 times sequentially every 1.5 seconds. 3 long beeps every 1.5 seconds. Dangerous smoke concentration is detected by the initiating unit in the network. Please find the initiating unit and take action.
The LED flashes red 4 times, then the green LED flashes once every 5.8 seconds. 4 quick repeating beeps every 5.8 seconds. Dangerous CO concentration is detected by the initiating unit, and has reached the alarm status. Please find the initiating unit and take action.
Unit detects CO (alarm not initiated). A CO concentration level ranging from 30 to 999 ppm has been detected, but for less than the allotted detection period. The LED indicator flashes green once every 60 seconds. None. Dangerous CO concentration is detected, but has not reached the alarm status. Potentially dangerous CO conditions exist.
Please search for the CO source first. Open nearby windows and doors, and immediately move to fresh air.
Unit detected smoke and initiated an alarm. - The LED indicator flashes green once every second for 5 seconds. None. Alarm cancellation: when the smoke concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Unit detected CO and initiated an alarm. - The LED indicator flashes green once every second for 5 seconds. None. Alarm cancellation: when the CO concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Test Mode Test a single unit. 2 sets of 3 red flashes followed by 2 sets of 4 red flashes. 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps. Press the Test/Silence button.
Test all interconnected units. The LED indicator flashes red rapidly. Continuous beeping until you release the Test/Silence button. Initiating alarm.
Hold down the Test/Silence button on one unit in the network.
The LED flashes red and green sequentially. Other interconnected alarms in the network.
Silence Mode - Flashes red 3 times every 1.5 seconds. None. Smoke silence mode: After 9 minutes, the unit will exit silence mode.
Flashes red 4 times every 5.8 seconds. None. СО silence mode: After 9 minutes, the unit will exit silence mode.
Flashes yellow once every 60 seconds. None. Silence mode during low battery: After 10 hours, the unit will exit silence mode.
Flashes yellow 3 times every 60 seconds. None. Silence mode during the end of cycle: After 22 hours, the unit will exit silence mode.
- Flashes green 3 times. None. Exiting silence mode.
Low Battery Flashes yellow once every 60 seconds. One beep every 60 seconds. Replace the unit immediately.
Fault Flashes yellow 2 times every 60 seconds. 2 beeps every 60 seconds. Please clean your alarm and see if it is working normally. lf "Err" continues to display, the unit has malfunctioned and must bе replaced immediately.
End of Life Flashes yellow 3 times every 60 seconds. 3 beeps every 60 seconds. Replace the unit immediately.

How to Set Up and Interconnect Wireless Alarms

AII X-Sense Link+ wireless interlinked alarms contain а built-in RF module that enables you to wirelessly connect 2 or more interlinked alarms and create an interlinked network. When one unit is triggered, all interconnected alarms will sound. The X-Sense Link+series contain wireless interlinked smoke alarms, wireless interlinked carbon monoxide alarms, and wireless interlinked smoke and carbon monoxide alarms. This model is designed to bе wirelessly interlinked with other X-Sense Link+ alarms, but is not designed to communicate with wireless interlinked alarms from other manufacturers.

The X-Sense Link+ wireless interlinked alarms in one multi-pack have already been interconnected, and the alarms in each multi-pack have their own independent interlinked network. lf you have more than one multi-pack, you will need to connect them all to the same network. Choose one multi-pack as your base network and connect the other multi-packs to it.

NOTE: The following instructions regarding wireless interconnection are applicable to the X-Sense Link+ wireless interlinked alarms only.

How to Interconnect

How to Interconnect

  1. Make sure you only work with 2 units at а time, and make sure that they are both turned on to ensure successful connection.
    NOTE: То turn оn SC06-W/SC07-W, attach the alarm properly to the mounting bracket and turn clockwise to lock it. То learn how to turn оn different models of wireless interlinked alarms, please refer to their specific user manuals for more details.
  2. Quickly press the test/silence button on one of the 2 units 4 times; it will beep once and the LED will flash red slowly, indicating it has entered pairing mode and is waiting for а new unit to bе added. Quickly press the test/silence button on the other unit twice; it will beep once and the LED will flash red rapidly, indicating it is searching for а device to connect to.
  3. After the search is successful and an interconnected group is created, both units will beep once and automatically exit the interconnection mode. At this point, both units will only flash once 60 seconds, indicating they are in normal standby mode.
  4. lf you want to connect а third alarm to this group, first activate а new device according to its operating instructions, and then quickly press the test/silence button on either of the 2 previously interconnected units 4 times. This unit will beep once, and the LED will flash red slowly, indicating it is ready to add а new device to the network. Next, quickly press the test/silence button on the new unit twice, and the LED will flash red rapidly as it searches for а network to connect to. After the third unit successfully joins the interconnected network, both units will beep once and automatically exit the interconnection mode.
  5. lf you want to connect more units, simply repeat step 4. Up to 24 alarms can bе interconnected this way. То ensure that all alarms enter the same interlinked network, make sure you only work with 2 units at а time-one unit enters the pairing mode and the other unit enters the searching mode.
  6. Test the alarms according to the steps in the section "Alarm Test:'

NOTES

  1. The alarm will enter the searching mode or the pairing mode for 60 seconds with the LED flashing red. After 60 seconds, repeat step 2 to connect the alarms. lf needed, press the test/silence button once while the alarm is in the searching mode or the pairing mode, and the LED will stop flashing red and the alarm will quit the pairing mode to enter normal status.
  2. Test all wireless alarms to ensure they are interconnected before installation.
  3. А maximum of 24 wireless alarms can bе interconnected оn the same network.
  4. The model can only bе interconnected with other X-Sense Link+ wireless interlinked alarms.

How to Disconnect

Press the test/silence button 4 times; the alarm will beep once. Then, hold down the button until it beeps once more to disconnect. After disconnecting, it can bе reconnected to the same network, or added to а new network.

NOTE: The X-Sense Link+ wireless interlinked alarms in one multi-pack have already been interconnected. То create а new network, you will first need to disconnect each alarm individually in this multi-pack to avoid having them all join the same network.

Alarm Mode

X- Sense Link+ wireless interlinked alarms can bе interconnected such that any unit that senses danger will cause all other units in the interconnected network to alarm.

lf the Initiating Unit ls Triggered by Smoke

When one smoke alarm is triggered in the interconnected network, the unit will beep 3 times, paired with the LED that flashes red every 1.5 seconds. Any other SC06-W/SC07-W units will follow suit-they will beep 3 times every 1.5 seconds, paired with the LED flashing red and green in succession.

lf the Initiating Unit is Triggered bY СО

When one СО alarm is triggered in the interconnected network, the unit will beep 4 times every 5.8 seconds, paired with the LED flashing red. Any other SC06-W/SC07-W units in the network will follow suit-they will beep 4 times every 5.8 seconds, paired with the LED that flashes red 4 times first, followed by the LED that flashes green once with every beep. When the СО concentration level drops below the alarm threshold, the alarm will cease.

NOTES

  1. When one unit is triggered, other interconnected units will sound. lf the smoke alarm and СО alarm are triggered in the network at the same time, the alarm signal of the smoke alarm will take priority over that of the СО alarm.
  2. This alarm has а relay function that extends the wireless interconnected network for wide detection coverage.

Alarm Test

Ве sure to test your alarms when you turn them on for the first time, or when the group configuration has changed. ln addition to the weekly tests you should perform, it is recommended to test the alarm after returning from а long trip or vacation.

lf your X-Sense Link+ SC06-W/SC07-W is interconnected to other X-Sense wireless alarms, we recommend that every individual alarm is tested during the weekly test.

Test a Single Alarm Test All Interconnected Alarms
Action Press the test/silence button. Hold down the test/silence button.
Indication
  • The alarm will emit 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps.
  • The LED will flash red during the audible signal.
  • For model SC07-W: You should first wake up your alarm by pressing the test button. The LCD will turn on and the backlight will bе lit.
  • After testing, the alarm will automatically enter standby mode.
  • The initiating unit will beep continuously with the LED flashing red.
  • Other interconnected alarms in the network will receive the signal after 5 seconds, then they will beep continuously with the LED flashing red and green successively. Release the test/silence button and all the units will stop testing.
  • The units testing should bе completed within 3 minutes.
  • After testing, the units will automatically enter standby mode.

NOTE: The test function accurately tests the alarm's circuits without the need to test with smoke and СО. lf your alarm fails to give аn audible test signal, please refer immediately to the troubleshooting guide at the end of this manual.

Basic Safety Information

  1. DANGERS, WARNINGS, AND CAUTIONS ALERT YOU ТО IMPORTANT OPERATING INSTRUCTIONS OR ТО POTENTIALLY HAZARDOUS SITUATIONS. PAY SPECIAL ATTENTION ТО THESE SITUATIONS.
  2. THIS COMBINATION SMOKE & CARBON MONOXIDE ALARM IS ONLY APPROVED FOR HOME USE.
  3. THIS CARBON MONOXIDE ALARM IS DESIGNED ТО DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION.
  4. CONSTANT EXPOSURES ТО HIGH OR LOW HUMIDITY MAY REDUCE BATTERY LIFE.
  5. SMOKE ALARMS ARE NOT TO ВЕ USED WITH DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.


THIS SMOKE & CARBON MONOXIDE ALARM HAS TWO SEPARATE ALARMS WHICH WORK INDEPENDENTLY.THE CARBON MONOXIDE ALARM IS NOT DESIGNED ТО DETECT FIRE OR ANY OTHER GAS. IT WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS АТ THE SENSOR. CARBON MONOXIDE GAS MAY ВЕ PRESENT IN OTHER AREAS. THE SMOKE ALARM WILL ONLY INDICATE THE PRESENCE OF SMOKE THAT REACHES THE SENSOR. THE SMOKE ALARM IS NOT DESIGNED ТО DETECT GAS, HEAT OR FLAMES.

  1. NEVER IGNORE ANY ALARM. FAILURE ТО RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH.
  2. THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT А PROBLEM. ALWAYS CHECK YOUR HOME FOR А POTENTIAL PROBLEM AFTER ANY ALARM. FAILURE ТО DO SO CAN RESULT IN INJURY OR DEATH.
  3. TEST THIS SMOKE/CO ALARM ONCE А WEEK. IF THE ALARM EVER FAILS ТО TEST CORRECTLY, REPLACE IT IMMEDIATELY! IF THE ALARM CANNOT WORK PROPERLY, IT WILL NOT ALERT YOU TO А PROBLEM.
  4. THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF FAMILY LIVING UNITS. IT IS NOT DESIGNED ТО MEASURE СО LEVELS IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) COMMERCIAL OR INDUSTRIAL STANDARDS. INDIVIDUALS WITH MEDICAL CONDITIONS THAT MAY MAKE THEM MORE SENSITIVE ТО CARBON MONOXIDE MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM. FOR ADDITIONAL INFORMATION ON CARBON MONOXIDE AND YOUR MEDICAL CONDITION CONTACT YOUR PHYSICIAN.
  5. THE REPLACEMENT DATE THAT APPEARS ON THE DEVICE IS THE DATE BEYOND WHICH THE DEVICE MAY NO LONGER DETECT CARBON MONOXIDE ACCURATELY AND 5HOULD ВЕ IMMEDIATELY REPLACED.
  6. THIS DEVICE IS DESIGNED ТО PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT А MEDICAL PRACTITIONER.

Installation Instructions

NOTE: Before installation, it is recommended to test the interconnected alarms in the rooms where you intend to install them to ensure that they are within transmission range and that nothing will interfere with their communication.

Installation Locations

Installation Locations

  1. Prioritize the installation of а smoke/CO alarm in the bedroom and walkways, and make sure you can hear the alarm from all sleeping areas. ln а home with several bedrooms, install an alarm in every bedroom. lf you install only one smoke alarm in your home, install the alarm near to all bedrooms where possible, and not in а basement or furnace room.
  2. Install an alarm above the stairway and on every floor of the house.
  3. Smoke, heat and anything burning will spread horizontally after rising to the ceiling, so install the alarm in the middle of the ceiling where possible. Ensure the alarm is within working distance of all corners of the room.
  4. lf an alarm cannot bе installed in the middle of а ceiling, install at а distance of 50 cm (20 inches) away from the corners of the room.
  5. lf an alarm is installed on а wall, it should bе at а distance of 10-30 cm (4-12 inches) below the ceiling.
  6. lf the length of а room or hall is beyond 900 cm (30 feet), several alarms should bе installed in the same room.
  7. When the wall or ceiling is angled, the alarm needs to bе installed within 90 cm (3 feet) of the highest wall or ceiling point (measured horizontally) in the room.
  8. ln multi-level houses or apartments, install at least one wireless alarm on each level and keep them installed in а straight vertical line (see diagram) with as few obstacles between each of the interconnected alarms as possible to ensure optimal signal transmission.

Locations to Avoid

  1. Near large metal surfaces and/or bundles of wire.
  2. Near fluorescent lights, amateur radios, electrical equipment, or other devices that may transmit an RF signal, as electronic noise may cause nuisance alarms.

  1. THIS ALARM SHOULD ВЕ INSTALLED ВY А COMPETENT PERSON.
  2. INSTALLATION OF THE ALARM SHOULD NOT ВЕ USED AS А SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.

Recommended Placement

How to Install This Alarm


THIS SMOKE/CO ALARM IS DESIGNED ТО ВЕ MOUNTED ON THE CEILING OR WALL.


FAILURE ТО PROPERLY INSTALL AND ACTIVATE THIS ALARM WILL PREVENT PROPER OPERATION OF THE ALARM AND WILL PREVENT ITS RESPONSE ТО FIRE HAZARDS.

Mounting Steps

  1. Mark three screw holes on the wall or ceiling according to the holes of the mounting bracket, and drill the screw holes to а depth of 30 mm (1.18 in) using а Ø6.0 mm (1/4 in) drill bit. Then insert three plastic anchor plugs into the holes with а hammer.
    Mounting
  2. Attach the mounting bracket to the surface of the wall or ceiling with three screws and mount the alarm into the bracket by pushing them together and twisting the unit clockwise.
  3. Test the unit by using the Test/Silence button. Ensure the unit sounds in an alarm pattern.
    NOTE: This model is equipped with а feature that automatically activates the alarm when the alarm is attached to the mounting bracket for the first time.

Deactivation of the Alarm

  1. DO NOT DEACTIVATE THE ALARM UNIT UNTIL THE END-OF-LIFE SIGNAL HAS BEEN HEARD.
  2. ONCE THE MAXIMUM LIFETIME (10 YEARS) IS REACHED, THE ALARM WILL DELIVER 3 BEEPS EVERY 60 SECONDS.
  3. ONCE THE ALARM IS DEACTIVATED, IT WILL NO LONGER FUNCTION. IT CANNOT ВЕ REACTIVATED AND MUST ВЕ REPLACED.

То Deactivate the Alarm

Pressing the Test/Silence button can silence the end-of-life signal for up to 3 days.

  1. Peel back the shaded label obstructing the "DIS" setting, and break the thin plastic guard, as below.
    То Deactivate the Alarm
  2. Twist the plastic pin upwards to the "DIS" position or insert а screwdriver into the slot and turn the dial clockwise to the "DIS" position.
  3. Dispose of the alarm.
  4. Replace the alarm.

Maintenance

То keep your smoke/CO alarm in good working order, follow these simple steps:

  1. Verify the unit's alarm sound and indicators are working properly by testing the unit once а week.
  2. Remove the unit from the ceiling/wall and clean the alarm cover and vents with а soft brush attachment once а month to remove dust and dirt.
  3. Never use detergents or other solvents to clean the unit.
  4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
  5. Do not paint the unit. Paint will seal the vents and interfere with the sensor's ability to detect smoke/CO. Never attempt to disassemble the unit or clean inside. Doing so will void your warranty.
  6. When removed, place the smoke/CO alarm back in its proper location as soon as possible, to assure continuous protection from fire.
  7. When household cleaning supplies or similar contaminants are used, the area should bе ventilated.

Troubleshooting

PROBLEMS SOLUTIONS
The alarm does not sound during а test.
  • Check whether the alarm is properly attached to the mounting bracket.
  • Make sure you have pushed the test/silence button firmly.
  • Check the installation positioning. The wireless signal might bе blocked or out of range.
False alarms are triggered intermittently when residents are cooking, taking showers, etc. Check the location of your alarm (see "Installation Locations").
Clean the alarm (see "Maintenance").
LED flashes yellow once every 60 seconds with one beep. The battery is low. Push the test/silence button once to silence for 10 hours. Replace the alarm immediately.
LED flashes yellow 2 times every 60 seconds with 2 beeps. The alarm is malfunctioning. Please clean your alarm or push the test/silence button once to attempt to reset the unit. lf the problem still occurs, replace the alarm immediately.
LED flashes yellow 3 times every 60 seconds with 3 beeps. The maximum lifetime (10 years) is reached. Push the Test/Silence button once to silence for 22 hours. Replace the alarm immediately.
LED flashes yellow 5 times every 60 second during the first 3 days, and 5 times every 60 minutes during the next 4 days. When the RF power supply is low, the RF module will no longer work, and the product will not interconnect with other units. lt will still function as а standalone unit, however.

Environmental Protection

Waste electrical products should not bе disposed of with household waste. Please recycle where facilities exist. Check with Local Authority or retailer for recycling advice.

Manufacturer and Service Information

X-Sense Innovations Со., Ltd.
Address: В4-503, Kexing Science Park, 15 Keyuan Road, Shenzhen, 518057, CHINA
Email: support@x-sense.com

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download X-Sense SCO6-W/SCO7-W - Wireless Smoke and Carbon Manual

Advertisement

Need help?

Need help?

Do you have a question about the SCO6-W and is the answer not in the manual?

Questions and answers

Table of Contents